PLANET NMS-500 NMS Controller Installation Guide
- June 13, 2024
- PLANET
Table of Contents
Enterprise-class Universal Network Management Controller
NMS-500
Quick Installation Guide
Package Contents
Thank you for purchasing PLANET Universal Network Management Controller.
The description of the model is shown below:
NMS-500 Enterprise-class Universal Network Management Controller
“NMS-500 Controller” is used as an alternative name in this Quick Installation
Guide.
Package Contents:
- The NMS-500 Controller x 1
- Quick Installation Guide x 1
- RS232 to RI45 Console Cable x 1
- Adapter with Power Cord x 1
- UTP Cable x 1
- Round Gasket x 4
If any item is found missing or damaged, contact your local reseller for replacement.
Hardware Description
2.1 Hardware Interface Definition
Interface | Description |
---|---|
Power Switch | Press the power switch to power on the device |
DC IN | DC jack power Input 12V 5A |
Console Port | Connect PC through the RS232 to R345 serial cable (115200, 8, N, |
- to enter the management interface
USB Port| Connect the USB HDD to enable USB backup/restoration function
Reset Button| < 5 sec: System reboot > 5 sec: Factory default
LAN Ports (1-5)| 10/100/1000BASE-T R345 auto-MDI/MDI-X ports
PWR LED| Indicates that the device is powered on (Blue)
LAN LED| Link: Steady Green (Green) Active: Flashing Green (Green)
LED Color Function
R345 LED | Color | Function |
---|---|---|
1000 LNK/ACT | Green | Lights |
at 1000Mbps.
Blinks| To indicate that the switch is actively sending or receiving data over
that port.
100 LNK/ACT| Orange| Lights| To indicate the port is successfully established
at 100Mbps.
Blinks| To indicate that the switch is actively sending or receiving data over
that port.
2.2 Physical Specifications
Dimensions (W x D x H) | 232 x 153 x 44 mm |
---|---|
Weight | 1.15 kg |
2.3 Product Features
- Dashboard: Providing the at-a-glance view of system and wireless network status.
- Node Discovery: To detect PLANET managed devices available and allow AP grouping to accelerate AP management.
- Topology Viewer: A topology of network devices compliant with SNMP, ONVIF, Smart Discovery and LLTD Protocol.
- Event Reports: The status of a network can be reported via network alarm, system log.
- SMPT Alarm: To send an email alert to the administrator via the SMTP server.
- Batch Provisioning: Enabling multiple APs to be configured and upgraded at one time by using the designated profile.
- Coverage Heat Map: Real-time signal coverage of APs on the user-defined floor map to optimize Wi-Fi field deployment.
- Customized Profile: Allowing the creation and maintenance of multiple wireless profiles.
- Auto Provisioning: Multi-AP provisioning with one click.
- Cluster Management: Simplifying high-density AP management.
- Zone Plan: Optimizing AP deployment with actual signal coverage.
- Authentication: Built-in RADIUS server seamlessly integrated into the enterprise network.
- User Control: Allowing on-demand account creation and user-defined access policy.
- Scalability: Free system upgrade and AP firmware bulk upgrade capability.
2.4 Specifications
Product | NMS-500 |
---|
Enterprise-class Universal Network Management Controller
Platform
Form Factor| Desktop
Physical Specifications
I/O Interface| Five10/100/1000BASE-T RA5 ports with auto-MDI/ MDI-X
2 USB 3.0 ports (They cannot be used at the same time.)
1 RS232-to-RAS console port (115200, 8, N, 1)
1 DC jack power Input
1 power switch
1 reset button
Storage| 8GB EMMC5.1, 15nm/2 eMLC
Dimensions (W x D x H)| 232 x 153 x 44 mm
Weight| 1.15 kg
Enclosure| Metal
Power Requirement| 60W adapter 12V 5A with DC jack
AC 100-240V, 3-1.5A, 60-50Hz.
Environment & Certification
Temperature| Operating: 0 –, 40 degrees C
Storage: -20 — 75 degrees C
Humidity| Operating: 10 — 85% (non-condensing)
Storage: 10 ru 85% @ 40 degrees C (non-condensing)
MTBF (Hours)| 120,000 @ 25 degrees C
Devices Management
Number of Managed Devices 1| 512
Number of RADIUS Client Devices2| 512
Number of RADIUS User Accounts*3| 10,000
Network Management Feature
Auto Discovery| Supports PLANET devices auto discovery
Dashboard| Summarized system overview includes online device numbers,
activated dient number
Device List| Allows creation and maintenance of device profiles
Topology View| Provides visual topology view of connected PLANET devices
Status Monitoring| Real-time online/offline of devices
Event and Syslog Report| Real-time system event and syslog server supported
SMTP Alarm| E-mail alert to the administrator via the SMTP server
SSID/RF Profile| Allows creation and maintenance of multiple wireless profiles
Cluster Management| Allows AP grouping for bulk provisioning and batch
upgrading
Bulk AP Provisioning| Supports bulk AP provisioning with user-defined profiles
Bulk AP Firmware Upgrade| Supports bulk AP firmware upgrade
Coverage Heat Map| Enables real signal coverage of managed AP reflecting on
the uploaded zone maps
Graphical Statistics| Real-time and historical visibility of wireless traffic
flow
Backup/Restoration| Provides system and profile backup/restoration
SSIDs-to-VLANs Ma in
pp g| Allows to configure SSIDs-to-VLANs mapping in supported APs
RADIUS Authentication| RADIUS server is integrated for client authentication
in a large-scale enterprise network
User Account Management| Supports on-demand account creation per user-defined
access policypolicy
Network Services
Network| DDNS| Supports PLANET DDNS/Easy DDNS
DHCP| Built-in DHCP server for auto IP assignment to APs
Management| Console; Telnet; SSL; Web browser (Chrome is recommended); SNMP
vl, v2c, v3
Discovery| Supports SNMP, ONVIF, PLANET Smart Discovery
Maintenance| Backup| System backup and restore to local or USB HDD
---|---|---
Reboot| Provides system reboot manually or automatically per power schedule
Diagnostic| Provides IPv4/IPv6 ping and trace route
Standards Conformance
Regulatory Compliance| CE, FCC
Standards Compliance| IEEE 802.3 10BASE-T
IEEE 802.3u 100BASE-TX
IEEE 802.3ab Gigabit 1000BASE-T
IEEE 802.3x Flow control and back pressure
IEEE 802.3z Flow control with Rx thresholds and Tx pause frames
Remark: 1 Please refer to user’s manual under Appendix to get last
support model and firmware list on the web site.
2 *3 For RADIUS dlient devices and user account settings, please refer to user’s manual under System Menu – Network Services.
Deployed Devices Monitored via NMS-500 Controller
The NMS-500 incorporated in a workstation or PC can monitor all the deployed
wired or wireless PoE industrial-grade network devices, such as managed
switches, media converters, routers, smart APs, VoIP phones, IP cameras, etc.
compliant with the MQTT Protocol, SNMP Protocol, ONVIF Protocol and PLANET
Smart Discovery utility.
Please regularly check PLANET website for the latest compatibility list of
managed devices.
Follow the steps below to set up the device from the “Standalone device” mode
to the “Managed device” mode.
Step 1. Connect the devices, NMS-500 Controller and your computer, to the same
network.
Step 2. Switch/Router: Log in to the Switch’s Web User Interface and enable
the SNMP, LLDP and NMS controller functions.
AP: Log in to the AP’s Web User Interface to configure the AP to “Managed AP”.
In support of SNMP AP, enable the SNMP function.
IP Cam: The ONVIF function is enabled by default. NMS controller can discover
PLANET IP camera directly.
Switch/Router
Wired Network Configuration
A computer with wired Ethernet connection is required for the first-time configuration of the NMS-500 Controller.
- Go to “Control Panel-> Network and Sharing Center-> Change Adapter Settings”.
- Double-click “Local Area Connection”.
- Select “Internet Protocol version 4 (TCP/IPv4)” and dick “Properties”.
- Select “Use the following IP address” and then click the “OK” button twice to save the configuration. For example, the default IP address of the NMS-500 Controller is 192.168.1.100, then the manager PC should be set to 192.168.1.x (where x is a number between 1 and 254, except 100), and the default subnet mask is 255.255.255.0.
Entering into the Web Management
Default IP Address: 192.168.1.100
Default Management Port: 8888
Default Usemame: admin
Default Password: admin
Launch the Web browser (Google Chrome with seamless mode is recommended.)
and enter the default IP address “https://192.168.1.100:8888“. Then, enter
the default username and password shown above to log on to the system.
The secure login with SSL (HTTPS) prefix is required.
After logging on, connect the NMS-500 Controller to the managed network to centrally control PLANET managed devices.
Setup Wizard
-
Account Modification: Set a new account and password for security.
-
1IP Configuration Setting: Set the NMS-500V’s IP into the same local network segment.
-
SNMP Preference Setting: Select region for AP Control (ETSI or FCC) and set up RO/RW community password.
-
Devices Discovery: Search the managed devices and add to list. (Finish Wizard)
Further Information
The above steps introduce the simple installations and configurations of the
NMS-500 Controller. For further configurations of PLANET UNI-NMS, please refer
to the user manual, which can be downloaded from the website.
PLANET online FAQs: http://www.planet.com.tw/en/support/fa
Support team mail address:
support@planet.com.tw
User’s Manual: https://www.planet.com.tw/en/product/nms-500
https://www.planet.com.tw/en/product/nms-500
(Please select your model name from the Product Model drop-down menu)
If you have further questions, please contact the local dealer or distributor
where you purchased this product.
Copyright © PLANET Technology Corp. 2022
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
All other trademarks belong to their respective owners.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>