  1. EXHAUST FUMES ARE POISONOUS

    • Never operate the engine in a closed area or it may cause unconsciousness and death within a short time.
      Operate the engine in a well ventilated area.
  2. FUEL IS HIGHLY FLAMMABLE AND POISONOUS

    • Always turn off the engine when refuelling
    • Never refuel while smoking or in the vicinity of an open flame.
    • Take care not to spill any fuel on the engine or muffler when refuelling.
    • If you swallow any fuel, inhale fuel vapour, or allow any to get in your eyes, see your doctor immediately. If any fuel spills on your skin or clothing, immediately wash with soap and water and change your clothes.
    • When operating or transporting the machine, be sure it is kept upright. If it tilts, fuel may leak from the carburettor or fuel tank.
  3. ENGINE AND MUFFLER MAY BE HOT

    • Place the machine in a place where pedestrians or children are not likely to touch the machine.
    • Avoid placing any flammable materials near the exhaust outlet during operation.
    • Keep the machine at least 1 m ( 3 ft ) from buildings or other equipment, or the engine may overheat.
    • Avoid operating the engine with a dust cover.
    • Be sure to carry the generator only by its carrying handle.
    • Put the machine on the flat ground, so it can eliminate heat freely.
  4. ELECTRIC SHOCK PREVENTION

    • Never operate the engine in rain or snow.

    • Never touch the machine with wet hands or electrical shock will occur.

    • Be sure to ground (earth) the generator.
      NOTE:

    • Use ground (earth) lead of sufficient current capacity.

    • Diameter: 0.12mm (0.005 in)/ampere

    • EX: 10 Ampere –1.2mm (0.055 in)

  5. CONNECTION NOTES

    • Avoid connecting the generator to a commercial power outlet.
    • Avoid connecting the generator in parallel with any other generator

CONTROL FUNCTION

  1. Control Panel
  2. Choke Knob
  3. Handle
  4. Fuel Switch (Petcock)
  5. Recoil Starter
  6. Muffler
  7. Muffler Cover
  8. Fuel Tank
  9. Fuel Tank Cap
  10. Fuel Guage
  11. Air Filter
  12. Battery Tray

Control Functions
Control Functions

**Stand Installation

**

Wheels Installation
Wheels Installation

OIL WARNING SYSTEM

  • When the oil level falls below the lower level, the engine stops automatically. Unless you refill with oil, the engine will not start again.

ENGINE SWITCH

  • The engine switch controls the ignition system.
  • Ignition circuit is switched on. The engine can be started. “ON” (run)
  • Ignition circuit is switched off. The engine will not run. “OFF” (stop)

CAUTION:
Reduce the load to within the specified generator rated output if the DC circuit protector turns the engine off.

FUEL COCK

The fuel cock is used to supply fuel from the tank to the carburetto
Carburettor

NOTE:
Turn fuel cock to the ‘off’ position while transporting generator

BATTERY TRAY

This generator includes an optional electric start function, the recommended battery size is 12V 17A.
Recommended dimensions: 17.8 x 7.4 x 16.5CM *Battery not included”
Battery Included

PRE-OPERATION CHECK

NOTE:
Pre-operation checks should be made each time the generator is used

CHECK ENGINE FUEL

  • Make sure there is sufficient fuel in the tank.
  • If fuel is low, refill with unleaded automotive gasoline.
  • Be sure to use the fuel filter screen.
  • Recommended fuel: Unleaded Petrol 95 Octane (DO NOT use ethanol or high octane fuels).
  • Fuel tank capacity: 25 litres.
    Check Engine

WARNING:

  • Do not refill tank while engine is running or hot.
  • Close fuel cock before refueling with fuel.
  • Be careful not to add dust, dirt, water or other foreign objects into fuel.
  • Do not overfill, a minimum of 0.64CM’s from the fuel cap is required to account for fuel expansion (2).
  • Wipe off spilt fuel thoroughly before starting engine.
  • Keep open flames away.

CHECK ENGINE OIL

  • Make sure the engine oil is at the upper level of the oil filler hole. Add oil as necessary.
  • Remove oil filler cap and check the engine oil level.
  • If oil level is below the lower level line, refill with suitable oil to upper level line. Do not screw in the oil filler cap when checking oil level.
  • Change oil if contaminated.
  • Fill oil until visible at the upper level of oil filler hole (Approx. 1100ML)

Recommended engine oil: SAE10 W30
Recommended Engine

GROUND (Earth)
Make sure to ground (earth) the generator.

OPERATION

NOTE:
The generator has been shipped without engine oil. Fill with oil or it will not start.

Do not tilt the generator when adding engine oil. This could result in overfilling and damage to the engine.

STARTING THE ENGINE

NOTE: BEFORE STARTING THE ENGINE, DO NOT CONNECT THE ELECTRIC APPARATUS.

  1. Turn the fuel cock lever to the “ON” position.

  2. Turn the engine switch to the “ON” position.

  3. Switch OFF the AC Circuit Breaker.

  4. Check there is adequate fuel in the tank.

  5. Set the choke lever to the choke position. Not necessary if the engine is warm.

  6. Pull the starter handle slowly until resistance is felt. This is the “Compression” point. Return the handle to its original position and pull swiftly. Do not fully pull out the rope. After starting, allow the starter handle to return to its original position while still holding the frame. Grasp the frame firmly to prevent the generator from falling over when pulling the recoil starter.

  7. Warm up the engine.

  8. Set the choke lever to the RUN/ON position.

  9. Warm up the engine without a load for a few minutes.

  10.  Switch ON the AC Circuit Breaker.

USING ELECTRIC POWER

A) AC APPLICATION

  1. Check the AC pilot lamp for proper voltage.
  2. Turn off the Switch(es) of the electrical appliance(s) before connecting to the generator.
  3. Insert the plug(s) of the electrical appliance(s) into the receptacle.
    Using Electric

CAUTION:

  • Be sure the electric apparatus is turned off before plugging in.
  • Be sure the total load is within generator rated output.
  • Be sure the socket load current is within socket rated current.
    Rated Current

B) OVERLOAD PROTECTION

The overload protection comes on when an overload of a connected electrical device is detected, the inverter unit overheats, or the AC output voltage rises. The electronic breaker will then activate, stopping power to the generator in order to protect the generator and any connected electric devices.

  1. Turn off any connected electric devices and stop the engine
  2. Reduce the total wattage of connected electric devices within the application range.
  3. After checking, restart the engine and reset the circuit breaker.

CAUTION:
The generator AC output automatically resets when the engine is stopped and then restarted.

C) DC APPLICATION (option)

This usage is applicable to 12V battery charging only.

  1. Charging instruction for battery

    • Disconnect the leads for the battery.
    • Make the battery fluid filler cap loose fully.
    • Fill distilled water to the upper limit, if the battery fluid is low level.
    • Measure the specific gravity for the battery fluid by using the hydrometer, and calculate the charging time in according with the table shown on right side.
    • The specific gravity for the fully charged battery shall be within 1.26 to 1.28.
      Overload Protections
  2. Connect the DC output socket and the battery terminals using the charging leads. The leads shall be connected making sure of the (+) and (-) polarity.

  3. The DC circuit protector is to be set to “ON” after confirming the connection, if the protector is in “OFF” position.
    Circuit Protector

3) STOPPING THE ENGINE

  1. Turn off the power switch of the electric apparatus or disconnect any electric devices.
  2. Turn the engine switch to “STOP” position.
  3. Turn the fuel cock lever to “OFF”

Electric Devices

PERIODIC MAINTENANCE

MAINTENANCE CHART

Regular maintenance is important for the best performance and safe operation of your generator.

Item| Remarks| Pre- operation check (daily)| Initial1 monthsor 20 Hr| Every3 months or 50Hr| Every6 months or100Hr| Every 12 months or 300Hr
---|---|---|---|---|---|---
Spark Plug| Check condition adjust gap and clean. Replace if necessary.| | |

  • | |
    Engine Oil| Check oil level| |

  • | | |
    Replace| |

  • | |

  • |
    Oil filter| Clean oil filter| | | |

  • |
    Air Filter| Clean. Replace if necessary.| | |

  • | |
    Fuel Filter| Clean fuel cock filter. Replace if necessary| | | |

  • |
    Choke| Check choke operation|

  • | | | |
    Valve Clearance| Check and adjust when engine is cold.| | | | |

Fuel Line| Check fuel hose for crack or damage. Replace if necessary.|

  • | | | |
    Exhaust System| Check for leakage. Retighten or replace gasket if necessary|

  • | | | |
    Check muffler screen. Clean / replace if necessary.| | | | |

Carburetor| Check choke operation|

  • | | | |
    Starting system| Check recoil starter operation.|

  • | | | |
    Idle speed| Check and adjust engine idle speed| | | | |

Fittings / Fasteners| Check all fittings and fasteners correct if necessary.| | | |

  • |
    Crankcase breather| Check breather hose for cracks or damage. Replace if necessary| | | | |

Generator| Check the pilot light comes on|

  • | | | |

ENGINE OIL REPLACEMENT

  1. Place the machine on a level surface and warm up the engine for several minutes. Then stop the engine and turn the fuel cock knob to “OFF””.
  2. Remove the oil filler cap (1).
  3. Place an oil pan under the engine. Tilt the generator to drain the oil completely
  4. Place the generator on a level surface.
  5. Re-install the screw
  6. Add engine oil to the upper level.
  7. Install the oil filler cap
  8. Recommended engine oil: **SAE10 W30

**

CAUTION:

  • Be sure no foreign material enters the crankcase.
  • Do not tilt the generator when adding engine oil. This could result in overfilling and damage to the engine
  • Clean the oil filter every other 100hr.
    Periodic Maintenance

AIR FILTER

Maintaining an air cleaner in proper condition is very important. Dirt induced through improperly installed, improperly serviced, or inadequate elements damages and wears out engines. Keep the element clean at all times

  1. Remove the air filter cover and element.
  2. Wash the element in solvent and dry.
  3. Oil the element with foam air filter oil and squeeze out any excess. The element should be wet but not dripping.
  4. Insert the element into the air filter.
  5. Install the air filter cover
    Periodic Maintenance

CAUTION:

  • The engine should never run without the element; excessive piston and/or cylinder wear may result.

CLEANING AND ADJUSTING SPARK PLUG

  1. Remove the ignition lead plug (1).

  2. Insert spark plug socket onto the spark plug.

  3. Turn counter clockwise to remove the spark plug.

  4. Check for discoloration and remove any excess carbon. The porcelain insulator around the centre electrode of the spark plug should be a medium to light tan colour.

  5. Ensure to use the following spark plug type and gap (a). Spark Plug: E6TC/E6RTC (Torch) Spark Plug Gap: 0.6-0.7mm (0.024-0.028in)

FUEL TANK FILTER

  1. Remove the fuel tank cap and filter.
  2. Clean the filter with solvent. If damaged, replace.
  3. Wipe the filter and insert it.
    Periodic Maintenance

CAUTION:
Be sure the tank cap is tightened securely

MUFFLER SCREEN

CAUTION

  • The engine and muffler will be very hot after the engine has been running.
  • Avoid touching the engine and muffler while they are still hot with any part of your body or clothing during inspection or repair.
  1. Remove the muffler screen.
  2. Use the flathead screw driver to pry the spark arrester out from the muffler
  3. Remove the carbon deposits on the muffler screen and spark arrester using a wire brush.
  4. Install the spark arrester and muffler screen.
  5. Install the cover

TROUBLE SHOOTING

ENGINE WON’T START

  • Fuel systems
    • No fuel supplied to combustion chamber.
    • No fuel in tank… Supply fuel.
    • Fuel in tank… fuel cock knob to “ON”.
    • Clogged fuel line… Flush fuel lines.
    • Clogged carburettor… Clean carburettor.
  • Engine oil system
    • Insufficient
    • Oil level is low… Add engine oil.
  • Electrical systems
    • Poor spark
    • Spark plug dirty with carbon or wet… Remove carbon or wipe spark plug dry.
    • Faulty ignition system… Consult dealer.
  • Compression insufficient
    • Worn out piston and cylinder… Consult dealer.

GENERATOR WON’T PRODUCE POWER

  • If Safety device (AC) is switched to “OFF” …Switch Circuit Breaker “ON”.
  • If Safety device (DC) is switched to “OFF”…Press to reset the DC protector.

STORAGE

Long term storage of your machine will require some preventive procedures to guard against deterioration.

DRAIN THE FUEL

  1. Remove the fuel tank cap, drain the fuel from the fuel tank
  2. Drain fuel from the carburettor by loosening the drain screw.

ENGINE

  1. Remove the spark plug, pour in about one tablespoon of SAE 10W30 or 20W40 motor oil into the spark plug hole and reinstall the spark plug.
  2. Use the recoil starter to turn the engine over several times (with ignition off).
  3. Pull the recoil starter until you feel compression.
  4. Stop pulling.
  5. Clean exterior of the generator and apply a rust inhibitor.
  6. Store the generator in a dry, well-ventilated place, with the cover place over it.
  7. The generator must remain in a vertical position.

SPECIFICATIONS

MODEL BS6500
AC Voltage 240V
Frequency 50Hz
Max. Output 5.5 kW
Rated Output 5.0 kW
Power Factor 0.8
DC Output 12V/8.3A (Option)
**ENGINE** Model
Type Air-cooled, 4 stroke, OHV, Petrol Engine
Bore×Stroke 88mm × 64mm
Displacement 389cc
Max. Output 5.5 kW / 3600rpm
Fuel Unleaded petrol (95 octane – no ethanol)
Fuel tank Capacity 25 litres
Rated Continuous Operation (70% of rated load) 9hrs
Lubricating oil SAE 10W30
Lubricating oil Capacity 1.1 litres
Starting System Recoil Starter/ Electric
Ignition system T.C.I. (Transistor Coil Ignition)
Spark Plug: Type F7TC/ F7RTC (Torch)
DIMENSION Net dimension
Overall dimension 720mm × 530mm × 580mm (L×W×H)
Net Weight 82 Kg
Gross Weight 85 Kg
  • Specifications subject to change without prior notice.

WIRING DIAGRAM

4) 3~5kW Key Start Generator Diagram

Wiring Diagram

WARNING: THE OUTPUT OF THIS GENERATOR CAN CAUSE INJURY OR DEATH.

DO NOT operate this generator near water or in damp/ wet conditions.

Avoid operating this generator with damp or wet hands.

This generator is not weatherproof.

Ethanol or high octane fuels should not be used in this generator.

CAUTION generator has hot surfaces during and after use.

NEVER connect this generator to a domestic or commercial power supply.

THIS GENERATOR SHOULD NOT BE CONNECTED TO ANY FIXED ELECTRICAL INSTALLATION.

Switch off engine when refuelling.

NEVER operate generator while smoking or intoxicated.

Misuse of generator may result in a potential danger of an explosion of fire.

This generator is NOT designed to be operated by persons with reduced mental and physical capabilities or children.

Appliances MUST be OFF before connecting to this generator.

NEVER START or stop this generator with extension leads, appliances or loads connected.

ALWAYS disconnect extension leads, appliances or loads before stopping this generator.

AVOID breathing in fuel or exhaust fumes.

Ensure when not in use or being transported the fuel cock is in the off position and the fuel filler breather is closed.

This generator must not be laid on its side – always mount upright with the rubber feet on the ground.

Check engine oil level before each start.

DANGER: Do not use indoors or poorly ventilated conditions.
Carbon monoxide fumes from the exhaust can kill in minutes.

WARRANTY 24 MONTH LIMITED

WARRANTY PERIOD:
Full 24 month warranty from date of purchase against all manufacturing defects

WHAT DOES THE WARRANTY COVER?
Under normal usage conditions, this warranty covers:

a. Any defect in design or manufacture which results in the product failing to perform substantially as described in authorised advertising or literature.

b. We will either repair or replace the product at our discretion providing that the fault is found to have been caused by a design or manufacturing defect and not misuse or tampering.

Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. The benefits provided to you as the consumer by this warranty are in addition to other rights and remedies available to you under the law.

THE WARRANTY DOES NOT COVER:

  • a. Any damage resulting from improper use
  • b. Faulty installation or modification made during installation
  • c. The cost of removing and reinstalling the product
  • d. Travel and /or other expenses due to customer’s remote location
  • e. Transport charges and damage in transit. It is your responsibility to deliver and pick up your product, including any costs associated with the postage of your repair or replacement product. If you do freight your product we recommend that you insure against loss or damage.
  • f. Any loss directly or indirectly associated with the product failing to operate.

TO MAKE A CLAIM UNDER THIS WARRANTY PLEASE CALL
1800 88 39 64

OUTDOOR SUPACENTRE PTY LTD
2 Stanley St Silverwater NSW, 2128
PHONE: 1800 88 39 64
www.4wdsupacentre.com.au

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals