ThermoWorks OutWard Instant Read Thermometer Instruction Manual

June 13, 2024
ThermoWorks

OutWard™
Operating Instructions

OutWard Instant Read Thermometer

  • Accuracy to ±0.9°F (±0.5°C)
  • 2-3 second readings
  • –58 to 572°F range
  • Calibration trim
  • NIST-traceable certificate
  • 180° auto-rotating display
  • IP67 rating
  • Backlight
  • °C/°F switchable

Instrument Operation

Press the power button to activate the thermometer. Temperatures will be displayed and the display will auto-rotate depending on orientation. The thermometer will turn off automatically after 10 minutes. This can be disabled. Press and hold the power button for 3 seconds to turn off. To activate the backlight, press the power button once while the instrument is turned on. Press again to turn off. Insert the stainless steel probe to the desired depth. The measured temperature will be shown on the LCD display within 2-3 seconds.
Auto-Off
To disable: Press button times. Display will flash OFF twice
To enable: Press button times. Display will flash ON twice.
Auto-off setting is saved even if instrument is turned off. Replace the battery when low battery symbol ‘Bat’ flashes.
Replace with a 3-volt, type CR2032, button-cell battery or equivalent.
Use a screwdriver of suitable size to open the battery cover on the back.
Install the battery observing the correct polarity, (+) positive side up, sliding the battery under the metal clip. Close the battery cover. ThermoWorks OutWard Instant Read Thermometer - powerTo Select ˚F or ˚C
Press the °C/°F button on the back of the thermometer to select the desired temperature unit.
Calibration Trim
From the factory OutWard should read within ±0.9°F and a calibration adjustment should never  be needed. For instructions on how and when to perform a one-point calibration trim go to www.thermoworks.com/outward.

Specifications

Measuring Range –58 to 572°F (–50 to 300°C)
Accuracy  ±0.9°F (±0.5°C) between 14 to 212°F (–10 to 100°C) ±4.5°F (±2.5°C)

between 392 to 572°F (200 to 300°C); otherwise ±2.7°F (±1.5°C)
Display Resolution| 0.1° over full range
Response| 2 to 3 seconds
IP Rating| IP67
Operating Range| 32 to 122°F (0 to 50°C)
Probe| 4.5 L x 0.09 inch dia. reduces to 0.06 inches dia.
(114 L x 2.5 mm dia. reduces to 1.6 mm dia.)
Auto-Off| After 10 minutes, can be disabled
Backlight| 10 seconds
Battery| CR2032 (3V) lithium coin cell (included) x 1, 5,000 hours
Display| 0.70 H x 1.3 W inches (18 H x 33 W mm);  Digits: 0.6 H inches (15 H mm)
Product Size| 2.7 W x 1.2 H x 1.02 D inches (70 W x 31 H x 26 D mm)

Care and Cleaning

Clean the probe immediately after each measurement to avoid cross contamination. Do not expose the thermometer body to temperatures over 122°F (50°C). Do not leave inside ovens.
Avoid submersing the entire thermometer.

Technical Support

For warranty, service, and technical assistance, please contact ThermoWorks’ Technical Support at 801-756-7705 or email at techsupport@thermoworks.com.
For additional cooking tips and doneness temperatures, and to see the full line of ThermoWorks tools, visit our website at www.thermoworks.com.
Chef-Recommended Temps
For additional temperature recommendations, go to blog.thermoworks.com

Beef, Veal & Lamb
Roasts, Steaks & Chops| Rare
120-130°F
49-54°C| Med. Rare
130-135°F

54-57°C| Medium
135-145°F
57-63°C| Med. Well
145-155°F

63-68°C| Well Done
**155°F-up*
68°C-up*
---|---|---|---|---|---
Pork
Roasts, Steaks & Chops| | USDA-Done
145°F

63°C| Well Done
150°F-up*
66°C-up
BBQ
Brisket, Ribs, & Pork Butt| | | Done
190-205°F
88-96°C

  • These temperatures are ideal peak temperatures. Meats should be removed from heat several degrees lower and allowed to rise during resting.
    ** Chef-recommended temperatures are consistent with many expert sources for taste and safety. USDA-recommended temperatures are 5 to 10°F (2 to 5°C) higher.

Minimum Done Temps for Food Safety

**Ground Meat: Beef, Veal, & Sausage*** 160°F (71°C)
Ham (raw) 160°F (71°C)
Ham (pre-cooked) 140°F (60°C)
Egg dishes 160°F (71°C)
Casseroles & Leftovers 165°F (74°C)
Chicken, Turkey & Duck (whole or pieces)* 165°F (74°C)
Poultry Dark Meat** 175°F (79°C)
Stuffing (in the bird) 165°F (74°C)
Tuna, Swordfish & Marlin** 125°F (52°C)
Other Fish** 140°F (60°C)

Water Temps (at sea level)

Poach 160-180°F (71-82°C)
Low Simmer 180°F (82°C)
Simmer 185°F (85°C)
Slow Boil 205°F (96°C)
Rolling Boil 212°F (100°C)

Other Food Temps

Bread: Rich Dough 190°F (88°C)
Bread: Lean Dough 200-210°F (93-99°C)
Water temp to add active dry yeast 105-115°F (41-46°C)
Butter: Chilled 35°F (2°C)
Butter: Softened 60-67°F (16-19°C)
Butter: Melted & Cooled 85-90°F (29-32°C)

Candy or Sugar Syrup Temps (at sea level)

Thread 230-234°F (110-112°C) Syrup
Soft Ball 234-240°F (112-116°C) Fondant, Fudge & Pralines
Firm Ball 244-248°F (118-120°C) Caramels
Hard Ball 250-266°F (121-130°C) Divinity & Nougat
Soft Crack 270-290°F (132-143°C) Taffy
Hard Crack 300-310°F (149-154°C) Brittles, Lollipops & Hardtack
Caramel 320-350°F (160-177°C) Flan & Caramel Cages

www.thermoworks.com
741 E. Utah Valley Dr.
American Fork, UT 84003
For service or warranty:
1-800-393-6434
1-801-756-7705
techsupport@thermoworks.com
P-23-003-02-b

Documents / Resources

| ThermoWorks OutWard Instant Read Thermometer [pdf] Instruction Manual
OutWard Instant Read Thermometer, Instant Read Thermometer, Read Thermometer, Thermometer
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

ThermoWorks User Manuals

Related Manuals