Beyerdynamic TG-D50D ynamic Cardioid Microphone for Drums User Manual
- June 13, 2024
- beyerdynamic
Table of Contents
Beyerdynamic TG-D50D ynamic Cardioid Microphone for Drums
Introduction
Thank you for selecting the TG D50d dynamic microphone from beyerdynamic. Please take some time to read carefully through this information before using the product.
Safety Information
- Protect the microphone from moisture and sudden impacts.
- You could damage the microphone!
- Do not blow into the microphone and do not knock on the microphone basket. Speak into the microphone or lightly scratch the microphone head grill to check functionality.
Applications
-
At the bottom next to the serial number of the TG50d there is a switch for LIN or EQ settings. If the switch has been set to LIN, the microphone can be used for miking toms, snare or other instruments.
-
If the switch has been set to EQ the microphone can be specially used for miking kick drums. By using the optional ST 99 stand, the microphone can either be placed in front or inside the kick drum.
Connection
The TG D50d is equipped with a 3-pin XLR plug. The microphone can be plugged into any balanced microphone input. Available cables for the microphone can be found under “Optional Accessories”. The use of phantom power does not damage the microphone.
Setting up
The TG D50d has a cardioid polar pattern and transmits very little feedback.
In order to maximise feedback suppression and ensure high crosstalk
attenuation, the microphone should be positioned in such a way that the
monitor speakers or other, loud sound sources are aimed at the microphone from
behind (angle approx. 180˚ to the longitudinal axis). The MKV 99 microphone
clip for stands with a 3/8″ and 5/8″ thread adapter is included in delivery of
the TG D50d.
Maintenance
The TG D50d may be cleaned with a soft, damp cloth as required. If necessary, a gentle cleaning agent (e.g. washing-up liquid) may be used – but on no account use a cleaner containing solvents. Make sure that no liquid penetrates the microphone head.
Service
Servicing must be carried out by qualified service personnel only, please contact your local dealer in this case. Dismantling the microphone yourself will invalidate the guarantee.
Version
- Model Description . . . . . . . . . . . . . . . . . . . . . . Order #
- TG D50d Dynamic drum microphone for lower-pitched instruments, cardioid, incl. MKV 99 microphone clamp . . . . . . . 707.430
Optional Accessories
- BMC 05 FM Standard microphone cable
- XLR-XLR, length 5 m . . . . . . . . . . . . . . . . 434.787
- BMC 10 FM Standard microphone cable
- XLR-XLR, length 10 m . . . . . . . . . . . . . . . 434.795
- MKV 87 Patented clamp for drum rim, 3/8″ . . . . . 459.356
- MKV 99 Microphone clamp . . . . . . . . . . . . . . . . . 471.909
- GST 590 Microphone stand, 3/8″, height 0.34 – 0.60m, with telescopic boom . . . . . . . . . . . . . . . 418.765
- ST 99 Miniature stand. . . . . . . . . . . . . . . . . . . . 471.917
Disposal
This symbol on the product, in the instructions or on the packaging means that your electrical and electronic equipment should be disposed at the end of its life separately from your household waste. There are separate collection systems for recycling in the EU. For more information, please contact the local authority or the retailer where you purchased the product.
Technical Specifications
- Transducer type . . . . . . . . . . . . . . . . . Dynamic
- Operating principle. . . . . . . . . . . . . . . Pressure gradient
- Polar pattern . . . . . . . . . . . . . . . . . . . Cardioid
- Frequency response
- Close miking (switch position LIN) . . . 50 – 17,000 Hz
- Close miking (switch position EQ) . . . 20 – 15,000 Hz
- Distant miking (switch position LIN, measured at 1 m). . . . . . . . . . . . . . . . 80 – 17,000 Hz
- Open circuit voltage
- (switch positon LIN) . . . . . . . . . . . . . . 2.4 mV/Pa (-52.5 dBV) ±3 dB
- Open circuit voltage
- (switch positon EQ) . . . . . . . . . . . . . . 0.9 mV/Pa (-60.9 dBV) ±3 dB
- Nominal impedance
- (switch position LIN) . . . . . . . . . . . . . . 600 Ω
- Nominal impedance
- (switch position EQ) . . . . . . . . . . . . . . 200 Ω
- Load impedance. . . . . . . . . . . . . . . . . ≥ 2 kΩ
- Connection . . . . . . . . . . . . . . . . . . . . 3-pin XLR connector, male
- Length . . . . . . . . . . . . . . . . . . . . . . . . 104 mm
- Shaft diameter . . . . . . . . . . . . . . . . . . 24 mm
- Head diameter . . . . . . . . . . . . . . . . . . 41 mm
- Weight (without clamp) . . . . . . . . . . . 134 g
- Weight (with clamp). . . . . . . . . . . . . . 189 g
Frequency Response Curve
Polar Pattern
Wiring Diagram
Beyerdynamic
- beyerdynamic GmbH & Co. KG
- Theresienstr. 8 | 74072 Heilbronn – Germany
- Tel. +49 (0) 7131 / 617 – 0 | Fax
- +49 (0) 7131 / 617 – 204
- info@beyerdynamic.de | www.beyerdynamic.com
- For further distributors worldwide, please go to www.beyerdynamic.com
- DEF2/PI TG D50d (07.12)/632.503/Hoh.
- Subject to change without notice
FAQs
What is the Beyerdynamic TG-D50D microphone designed for?
The Beyerdynamic TG-D50D microphone is specifically designed for miking drums and percussion instruments.
What type of microphone is the TG-D50D?
It is a dynamic cardioid microphone, ideal for capturing the sound of drums with clarity and precision.
Does this microphone come with a mounting clip or stand adapter?
Yes, it includes a mounting clip that allows you to easily attach it to a drum or stand.
What is the frequency response of this microphone?
The Beyerdynamic TG-D50D has a frequency response range of 50Hz to 17kHz, tailored for drum sounds.
Is the TG-D50D suitable for live performances?
Yes, it is well-suited for live performances as well as studio recording, thanks to its rugged construction.
Can this microphone handle high sound pressure levels (SPL)?
Absolutely, it can handle high SPLs, making it perfect for capturing loud drum hits without distortion.
Is the TG-D50D resistant to feedback?
Yes, its cardioid polar pattern helps reduce feedback and isolate the sound source.
Does it come with a protective case?
Yes, it typically includes a protective carrying case for safe storage and transportation.
Can I use this microphone for recording other instruments?
While designed for drums, you can use it for other instruments where a dynamic cardioid mic is suitable.
Does it require phantom power?
No, the TG-D50D is a dynamic microphone and does not require phantom power to operate.
Is there a warranty included with this microphone?
Yes, Beyerdynamic typically offers a warranty to ensure the microphone's quality and performance.
Can I use this microphone for recording vocals?
While it's designed for drums, you can use it for vocals, but it may not provide the same clarity as a dedicated vocal microphone.
Download This PDF Link: Beyerdynamic TG-D50D ynamic Cardioid Microphone for Drums User Manual
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>