beyerdynamic UNITE CDD-8 Desktop Charger User Guide
- June 4, 2024
- beyerdynamic
Table of Contents
beyerdynamic UNITE CDD-8 Desktop Charger
The Unite CDD and Unite CDS Cockpit chargers as well as the Unite DS-4/2 charger belong to the wireless Unite communication system from beyerdynamic. For detailed descriptions of the use, please refer to the operating instructions for the entire system, which you can download from the internet at: www.beyerdynamic.com/unite
Safety instructions
The exclamation mark within an equilateral triangle is intended to alert the
user to the presence of important operating and maintenance instructions in
the literature accompanying the product.
Disclaimer beyerdynamic GmbH & Co. KG will not be liable if any damage,
injury or accident occurs due to negligent, incorrect or inappropriate
operation of the product.
- Read these instructions.
- Keep these instructions.
- Heed all warnings.
- Follow all instructions.
- Do not use this device near water.
- Clean only with dry cloth.
- Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
- Do not install near any heat sources such as radiators, heat registers, stoves, or other device (including amplifiers) that produce heat.
- For safety purposes do not make any changes to the polarized or grounding type plug. A polarized plug has two contacts with one wider than the other. A grounding type plug has two contacts and a third grounding prong. The wide contact or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
- Protect the power cord by not walking or standing on it or pinching, this is considered for plugs especially where they exit from the device.
- Only use attachments/accessories specified by the manufacturer.
- Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the device. When a cart is used, use caution when moving the cart/device combination to avoid injury from tipping over.
- Unplug this device during lightning storms or when unused for long periods of time.
- Refer all servicing to qualified service personnel. Servicing is required when the device has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the device, the device has been exposed to rain or moisture, does not operate normally, or has been dropped.
Location
- The equipment must be set up so that the mains switch, mains plug and all connections on the rear of the device are easily accessible.
- If you transport the equipment to another location take care to ensure that it is adequately secured and can never be damaged by being dropped or by impacts on the equipment.
- Please operate the device only with sufficient ventilation. The ambient temperature for optimum charging operation is in the range 0 °C to 30 °C. If the ambient temperature is higher, the charging process is repeatedly interrupted and restarted to protect the battery. This leads to an extended charging time. Please make sure that the optimum ambient temperature is only exceeded temporarily and not permanently, otherwise the ageing process of the batteries will progress more quickly.
If you wish to operate the charger in a closed container, e.g. a drawer or in a cabinet, provide active ventilation to ensure the optimum ambient temperature (0 °C to 30 °C).
Do not under any circumstances cover the charger with objects during the charging process.
Fire hazard
Never place naked flames (e.g. candles) near the equipment.
Humidity / heat sources
- Never expose the equipment to rain or a high level of humidity. For this reason do not install it in the immediate vicinity of swimming pools, showers, damp basement rooms or other areas with unusually high atmospheric humidity.
- Never place objects containing liquid (e.g. vases or drinking glasses) on the equipment. Liquids in the equipment could cause a short circuit.
- Do not install near any heat sources such as radiators, heat registers, stoves or other device (including amplifiers) that produce heat.
Connection
- The equipment must be connected to a mains socket that has an earth contact.
- Protect the power cord by not walking or standing on it or pinching, this is considered for plugs especially where they exit from the device.
- Lay all connection cables so that they do not present a trip hazard.
- Whenever working on the equipment switch off all inputs and outputs to the power supply.
- Check whether the connection figures comply with the existing mains supply. Serious damage could occur due to connecting the system to the wrong power supply. An incorrect mains voltage could damage the equipment or cause an electric shock.
- If the equipment causes a blown fuse or a short circuit, disconnect it from the mains and have it checked and repaired.
- Do not hold the mains cable with wet hands. There must be no water or dust on the contact pins. In both cases you could receive an electric shock.
- The mains cable must be firmly connected. If it is loose there is a fire hazard.
- Always pull out the mains cable from the mains and/or from the equipment by the plug – never by the cable. The cable could be damaged and cause an electric shock or fire.
- Do not use the equipment if the mains plug is damaged.
- If you connect defective or unsuitable accessories, the charger could be damaged. Only use power supply units available from or recommended by beyerdynamic.
Switching off
- In order to switch off the device, also disconnect the power plug from the power socket. Make sure that you do not pull on the cable, but on the power plug.
Ventilation
- Do not insert objects into the ventilation grilles or other openings. You could damage the equipment and/or injure yourself.
Disconnect
- For pluggable equipment, the socket-outlet shall be near the equipment and shall be easily accessible.
Maintenance
- Only clean the equipment with a slightly damp or dry cloth. Never use solvents as these can damage the surface.
Trouble shooting and servicing
- Never open the device yourself. You could receive an electric shock. There are no user-serviceable parts inside.
- Leave all service work to authorised expert personnel.
Charging
- A completely new battery may need to be charged and discharged several times before it has reached its full change capacity.
- Do not throw used batteries in the household waste, but hand them over to the local collection points.
- High ambient temperatures during charging (> +40 °C) affect the efficiency of the charging process and the lifetime of the rechargeable battery.
Disposal
This symbol on the product, in the instructions or on the packaging means that
your electrical and electronic equipment should be disposed at the end of its
life separately from your house-hold waste. There are separate collection
systems for recycling in the EU. For more information, please contact the
local authority or your retailer where you purchased the product.
Versions
- Unite CDD-8/4 : Cockpit desktop charger for a maximum of 8 Unite bodypack transmitters / receivers. 4 of the 8 charging compartments are compatible with the Unite TH handheld transmitter. Network connection, USB-C connection, incl. power supply unit . . . . . . . . . . . . . Order # 708.488
- Unite CDS-4/2 : Cockpit desktop charger for a maximum of 4 Unite bodypack transmitters / receivers. 2 of the 4 charging compartments are compatible with the Unite TH handheld transmitter. Network connection, USB-C connection, incl. power supply unit . . . . . . . . . . . . . Order # 713.198
- Unite DS-4/2 : Desktop charger for a maximum of 4 Unite bodypack transmitters / receivers. 2 of the 4 charging compartments are compatible with the Unite TH handheld transmitter. Incl. power supply unit. Basic version for charging only without network function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Order # 717.916
Supplied accessories
Power supply unit:
- CDS-4/2 XP Power VET36US120C2-JA power supply unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Order # 679.216
- CDD-8/4 XP Power VEC50US12 power supply unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Order # 682.888
- DS-4/2 XP Power VET36US120C2-JA power supply unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Order # 679.216
Quick start guide
Controls and indicators
Top view of Unite CDS-4/2 | Unite DS-4/2
Top view of Unite CDD-8/4
- Charging compartment for bodypack transmitter or receiver
- Combined charging compartment for one handheld transmitter or bodypack device
Rear view of Unite CDS-4/2 | Unite CDD-8/4
- Operating control LED
- Button to start the pairing process or to clear saved pairing information in the charger
- Status display for pairing status and automatic pairing process
- Button for automatic pairing process
- Reset button for restoring the factory IP address setting
- Ethernet connection
- USB-C connection
- 12 V DC connection for power supply unit
Important:
- CDS-4/2: Please use only the supplied XP Power VET36US120C2-JA power supply unit!
- CDD-8/4: Please use only the supplied XP Power VEC50US12 power supply unit!
Rear view of Unite DS-4/2
- “Power” LED
- 12 V DC connection for power supply unite
Important:
- DS-4/2: Please use only the supplied XP Power VET36US120C2-JA power supply unit!
How to mount the desktop chargers on a table
The Unite CDS-4/2, Unite CDD-8/4 and Unite DS-4/2 Cockpit desktop chargers have holes on their bottom, which you can use to attach the chargers on a table with screws using a separate drilling template. Use M3 screws for this. The length of the screws depends on the thickness of the desktop.
- The screws for mounting must not penetrate the housing by more than 6 mm! The height of the rubber pads is approx. 3.4 mm. If necessary, you can remove the rubber pads before attaching. You will find an appropriate drawing in the data sheet on the respective product page at www.beyerdynamic.com
Bottom of Unite CDD-8/4
Bottom of Unite CDS-4/2 | Unite DS-4/2
How to operate the charger
The Unite CDD-8/4 and Unite CDS-4/2 Cockpit chargers are used to charge the batteries in the Unite transmitters and receivers and to transfer the pairing information from the transmitters to the receivers.
- The Unite CDD-8/4 Cockpit desktop charger has 8 charging compartments of which 4 are combined compartments for charging a handheld transmitter or bodypack device.
- The Unite CDS-4/2 Cockpit desktop charger has 4 charging compartments of which 2 are combined compartments for charging a handheld transmitter or bodypack device.
- The Unite DS-4/2 desktop charger is only used for charging the batteries in the transmitters and receivers. It has 4 charging compartments of which 2 are combined compartments for charging a handheld transmitter or bodypack device.
Mains connection
-
Connect the AC adapter with the power plug to a power outlet and with the DC plug to a 12 V DC
socket of the charger. -
The charger has no separate on/off switch and is immediately ready for use.
-
When the device is not in use, remove the mains plug from the power outlet. Make sure that you do not pull on the cable, but on the power plug.
-
Make sure that you connect only the supplied power supply unit to the Unite CDD-8/4, Unite CDS-4/2 and Unite DS-4/2 charger (refer also to “Supplied accessories”). The internal pin of the DC socket of the Unite CDD- 8/4 has a different diameter as the pin of the DC socket of the Unite CDS-4/2.
How to insert the transmitter/receiver into the charger
- Make sure that you insert the transmitter and receiver into the charging compartments so that the charging contacts of the transmitter / receiver are in contact with the charging contacts in the charger. The status display on the transmitter/receiver flashes green during charging.
Establish pairing – Unite CDD-8/4 and Unite CDS-4/2
Transmitters and receivers must be paired so that they can communicate with
each other. For a successful pairing the channel name, group ID and audio
encryption key are required. The required audio encryption key is generated in
the Unite CDD-8/4, CDS-4/2 Cockpit desktop charger or via the Unite Manager
software and during the pairing process it is first stored on the cockpit case
and then it is transferred to the transmitter and receiver in the charging
compartments.
There are three different ways to pair the Unite transmitters with receivers:
- Via an individual charger (refer to the following description or system manual online).
- Using the Unite Manager Software on a PC (refer to the Unite Manager Software manual or system manual online).
- Via dynamic channel search (refer to system manual online, chapter “Special functions”.
The group ID refers to devices that can be combined to a virtual group. For example, all devices of a building, a travel group or a conference room.
Use with the group ID 150 – 256
By default, the transmitters and receivers are supplied with the group ID 256.
A common factory-set audio encryption key, which cannot be changed, is used
for the group ID range of 150 to 256.
The audio encryption key ensures additional security against unauthorised
listening during the wireless transmission. Due to the factory-set audio
encryption key the devices within the group ID range of 150 to 256 can connect
to each other without pairing via the charger. In this case receivers can
connect to transmitters via the dynamic channel search.
Example: Via the dynamic channel search, a receiver which is set to the
group ID 160 will find all transmitters which are active and also set to the
group ID 160. The receiver can connect to a transmitter without pairing. The
receiver will not find transmitters beyond the set ID range of 160.
Attention: When using several transmitters (e.g. Unite AP4 and several Unite
TP) with the same group ID at the same time, make sure that the individual
channel names differ from each other! Otherwise this can cause connection
problems with the receivers!
Use with the individual group ID 1 – 149
If several receivers are to be divided into different groups with an
individual encryption, for each group an individual group ID between 1 and 149
can be assigned. A separate audio encryption key is generated for an
individual group ID in order to ensure additional security against
unauthorised listening during the wireless transmission. This audio encryption
key is generated during the pairing process, stored in the charger and
transmitted from the charger to the transmitter and receiver, along with the
channel name and group ID.
Since the audio encryption key is not transmitted via radio, it cannot be read
out. This gives the system maximum security against unauthorised listening.
The receivers can only connect to a transmitter with which they have been
paired via the charger. If the group ID is subsequently set manually on a
receiver which has not been paired, no connection can be established to the
transmitter with the encrypted group ID, because the receiver does not have
the audio encryption key.
In order to perform a simple pairing, proceed as described in the following:
-
Set the desired group ID and channel name on the transmitter you want to use for pairing. Refer also to chapter “Set group ID” and “Set channel name” of the “Unite TP – Bodypack Transmitter” or “Unite TH – Handheld Transmitter” quick start guide.
-
Insert only one transmitter into the charging compartment of the charger. If multiple transmitters are inserted into the charging compartments, the pairing will not start and the status indicator in the charger will display an error (see table). Further transmitters must be configured as sub-master so that they can be paired with a transmitter configured as a master. Furthermore, you can connect another transmitter / receiver to the USB port on the charger when using a USB cable type C.
-
Insert one or more receivers into the charging compartments of the charger to be paired with the transmitter. You can also connect another receiver to the charger using the USB port . Remove all receivers that should not be paired. If there is no receiver in the charging compartments, the pairing information is stored in the charger. This is used for later pairing without connecting the transmitter to the charger.
-
In order to transfer the pairing information from the transmitter to the receivers in the slots and to the charger itself for future pairing, press and hold the “Pair/Reset” button on the charger for more than 2 seconds. When the “Pairing Status” indicator flashes yellow, release the button to perform a pairing. Mobile devices that are now being paired indicate this via a status indicator that illuminates yellow. After successful pairing the “Pairing Status” indicator will permanently illuminate green to display that the pairing information is now also stored in the charger.
-
If you want to pair other receivers, remove the transmitter (Master) and all receivers from the charger and press the “Auto Pair” button once. The “Pairing Status” indicator will illuminate yellow. Insert the receivers that are not yet paired into the charger. The pairing information is immediately stored in these receivers. The “Pairing Status” indicator flashes yellow and displays the active pairing process. On the devices that have received the pairing information, the status indicator lights yellow for about 10 seconds. As soon as the “Pairing Status” indicator is permanently lit yellow, the pairing process is complete and you can remove the receivers from the charging compartments.
In order to end the “Auto Pair” function, press the “Auto Pair” button once. The “Pairing Status” indicator will illuminate green to indicate that the pairing information is stored in the charger.
The “Auto Pair” function is not possible, when no pairing information is stored in the charger. In this case the “Pairing Status” indicator flashes red five times. -
Switch on the transmitter and a receiver to check whether the pairing was successful. When the devices are successfully paired, the status indicator of both devices will illuminate green and the receiver should display the channel name of the transmitter.
-
In order to delete the stored pairing information, press the “Pair/Reset” button until the “Pairing Status” indicator first flashes yellow and the goes out.
The “Operating Status” indicator on the charger shows the following information:
Indicator light | Operating status |
---|---|
Off | Device is switched off |
Green | Device is ready to use |
Flashing green/yellow | Device is being localised |
Flashing red rapidly |
- Operating error
- Charging error
Red|
- Device reboots
- Device is in “Service mode”. Refer to chapter 5.7 “Service mode”.
- Device performs a firmware update
The “Pairing Status” indicator on the charger shows the following information:
Indicator light | Operating status |
---|---|
Off | No pairing informatin is stored |
Green | The pairing information is stored; the “Auto Pair” function is not |
active
Flashing yellow| The pairing information is copied to the charger or receiver
Yellow| The pairing information is stored in the charger and the “Auto Pair”
function is active
Flashes red 5 times|
- No transmitter
- Too many transmitters
- The “Auto Pair” button was pressed although no pairing information is stored
Red| No pairing possible – pairing locked via the Unite Manager PC software
Charging
-
If pairing is not required and you only want to charge the transmitter and receiver, place the transmitters and receivers in the appropriate charging compartments without activating the pairing process via the “Pair/Reset” or “Auto Pair” button.
If the stored pairing information is no longer needed, you can also delete it by pressing the “Pair/Reset” button for more than 5 seconds. When the “Pairing Status” indicator goes off, the pairing information is deleted. -
Insert the transmitters / receivers into the charging compartments so that the charging contacts of the transmitters / receivers have contact with those in the charging compartments.
-
Charging will start automatically.
-
The state of charge of the batteries is indicated by the LED of the appropriate transmitter / receiver:
Indicator light| Charging status
---|---
Off| Device is switched off
Flashing green slowly| Charging 0 – 100%
Green| Battery is charged
Flashing yellow slowly| Pairing information is being copied from the transmitter
Yellow for 10 seconds| Device information is copied successfully to charger/devices
Flashes red slowly for 10 seconds|- Too many transmitters in the charger when pairing is initiated
- Other pairing error
Flashing green/yellow rapidly| Device is being localised
Flashing red rapidly| Charging error
Red| Firmware update is performed
Conditioning the battery
- In order to achieve the maximum capacity of the battery, we recommend discharging the transmitters / receivers completely to carry out a complete charging cycle afterwards.
- This also increases the accuracy of the battery indicator on the display of the Unite transmitters / receivers.
Automatic Firmware Update with Unite CDD-8/4 and CDS-4/2
- By using the Unite Cockpit charger you can upload firmware updates to Unite transmitters / receivers.
- The Unite Cockpit desktop charger is factory set with the latest firmware for transmitter / receiver at the time of delivery. If you charge transmitters / receivers with older firmware with the charger, the firmware is also automatically updated. This ensures that the charger will work properly with the transmitter / receiver.
- During the firmware update the status indicator light of the Unite transmitters/receivers will illuminate red. This process will take approx. 5 minutes. During the firmware update do not disconnect the charger from the mains. Should the process take longer than 10 minutes, turn the Unite Cockpit charger off and on again. The update process will then restart.
- You can check the update on the transmitter / receiver:
Attention: Please note that after a successful update to a new firmware version, the Unite transmitters / receivers are no longer compatible with older firmware versions.
Reset factory settings of the charger
- If you want to restore the factory settings of the charger, press the “Reset” button on the rear of the charger. The charger will restart and restore the factory settings. A reset restores the following information:
- DHCP Setting back to “Use DHCP”
- Static IP address back to default setting 192.168.1.101
- Static Subnet mask back to default setting 255.255.255.0
- Static Gateway back to default setting 192.168.1.1
- Delete/deactivate the individually stored settings of the mobile devices (portable devices, i.e. bodypack,
- handheld).
- Deleting the stored pairing information
- Restoring the factory settings does not delete the pre-installed firmware update images!
Service mode
- For maximum operational safety, the Unite Cockpit charger is equipped with a so-called service mode.
- This means: If the device is disconnected from the mains within 15 seconds of being switched on (e.g. by accidentally switching it off), the device starts in a service mode and checks itself. This takes about 1 minute and is indicated by a red operating display on the rear of the charger. The Unite cockpit desktop charger then returns to the normal operating mode. This is indicated by a green operating display.
Technical specifications
Power supply unit
XP Power VET36US120C2-JA for Unite CDS-4/2 and DS-4/2
- AC input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 – 264 V, 47 – 63 Hz
- Nominal current . . . . . . . . . . . . . . . . . . . . . . . . 0.8 A @ 100 V AC
- Power consumption. . . . . . . . . . . . . . . . . . . . . 25 W with 4 charging compartments
- Output voltage . . . . . . . . . . . . . . . . . . . . . . . . . 12 V DC, 3 A
XP Power VEC50US12 for Unite CDD-8/4
- AC input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 – 264 V, 47 – 63 Hz
- Nominal current . . . . . . . . . . . . . . . . . . . . . . . . 1 A @ 115 V AC, 0.7 @ 230 V AC
- Power consumption. . . . . . . . . . . . . . . . . . . . . 50 W with 8 charging compartments
- Output voltage . . . . . . . . . . . . . . . . . . . . . . . . . 12 V DC, 4.17 A
Charger
Max. charging time
- Unite CDS-4/2 . . . . . . . . . . . . . . . . . . . . . . . . . approx. 4 hrs.
- Unite CDD-8/4 . . . . . . . . . . . . . . . . . . . . . . . . . approx. 4 hrs.
- Unite DS-4/2 . . . . . . . . . . . . . . . . . . . . . . . . . . . approx. 4 hrs.
Connections
- Unite CDS-4/2 and Unite CDD-8/4 . . . . . Ethernet
- USB type C (USB 2.0, 0.5 A)
Ambient temperature
- 0 to 30 °C optimum operation (in this range the specified charging time is observed)
- From 30 °C extended charging time (continuous operation is not recommended, see above)
- Above 40 °C operation is no longer possible
- Storage temperature: -20 to +50 °C
Dimensions (W x H x D) incl. base plates
- Unite CDS-4/2 . . . . . . . . . . . . . . . . . . . . . . . . . 147.5 x 75.5 x 78.5mm
- Unite CDD-8/4 . . . . . . . . . . . . . . . . . . . . . . . . . 147.5 x 75.5 x 163.5 mm
- Unite DS-4/2 . . . . . . . . . . . . . . . . . . . . . . . . . . . 147.5 x 75.5 x 78.5mm
Weight
- Unite CDS-4/2 . . . . . . . . . . . . . . . . . . . . . . . . . 555 g
- Unite CDD-8/4 . . . . . . . . . . . . . . . . . . . . . . . . . 1080 g
- Unite DS-4/2 . . . . . . . . . . . . . . . . . . . . . . . . . . . 530 g
Charging compartments
- Unite CDS-4/2, Unite DS-4/2. . . . . . . . . . . . 4 of which are 2 combined charging compartments for handheld / bodypack devices
- Unite CDD-8/4 . . . . . . . . . . . . . . . . . . . . . . . . . 8 of which are 4 combined charging compartments for handheld / bodypack devices
QR Codes
-
Unite Operating instructions
-
Unite Landing page
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>