beyerdynamic WA-CD NiMH Charger with 4 Charging Slots and Remote Control Instruction Manual

June 5, 2024
beyerdynamic

CHARGER
OPERATING INSTRUCTIONS

Thank you for selecting the WA-CD charger from beyerdynamic. Please take some time to read through this manual carefully before using this product.

Safety information

General

  • READ these instructions.
  • KEEP these instructions.
  • HEED all warnings and follow all instructions.

Exemption from liability

  • beyerdynamic GmbH & Co. KG will not be liable if any damage, injury or accident occurs due to negligent, incorrect or inappropriate operation of the product.

Humidity / heat sources

  • Never expose the equipment to rain or a high level of humidity. For this reason do not install it in the immediate vicinity of swimming pools, showers, damp basement rooms or other areas with unusually high atmospheric humidity.
  • Never place objects containing liquid (e.g. vases or drinking glasses) on the equipment. Liquids in the equipment could cause a short circuit.
  • Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus (including amplifiers) that produce heat.

Connection

  • Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
  • Unplug the device during lightning storms or when unused for long periods of time.
  • Only use attachments/accessories specified by the manufacturer.
  • Do not use the equipment if the power cable is damaged.

Charging

  • Never charge the handheld and beltpack transmitter with a normal battery! Damages caused by charging a transmitter with normal batteries will invalidate the guarantee.
  • A completely new rechargeable battery must be charged several times to achieve its full capacity.
  • Rechargeable batteries loose 20% of their capacity within one month. If the transmitter is not used for some time, recharging the battery is recommended.
  • Avoid recharging the batteries inside the transmitters several times in a quick succession. This could create an error while charging or damage the rechargeable battery.
  • Do not throw used batteries into the domestic rubbish, but hand them in to local collection points.
  • High ambient temperatures during charging (> +40 °C) affect the efficiency of the charging process and the battery lifetime.
  • The service life of the batteries largely depends on the manner in which they are looked after, on how well the user recharges them. To extend the service life of the batteries for as long as possible, please do not leave the transmitter permanently (24/7) in the charger connected to the mains. The batteries may age prematurely or be damaged. Therefore, always disconnect the charger from the mains, when the transmitter is not in use.
  • Only put the transmitter in the charger before a conference / application and fully charge it until the “fully charged” status is shown.
  • In particular, when the transmitter is inserted, avoid connecting and disconnecting the charger from the mains regularly. For each charging cycle, there is an initial 5-minute charge to check the battery status. If the charger, with the inserted transmitter, is started again every day, the transmitter will be slowly but constantly overcharged and this will damage the batteries.

Maintenance

  • Only clean the equipment with a dry cloth.

Trouble shooting and servicing

  • Do not open the equipment without authorisation. You could receive an electric shock. No user serviceable parts inside.
  • Refer all servicing to qualified service personnel.

Disposal

  • This symbol on the product, in the instructions or on the packaging means that your electrical and electronic equipment should be disposed at the end of its life separately from your household waste. There are separate collection systems for recycling in the EU. For more information, please contact the local authority or your retailer where you purchased the product.

Functions

  • Separate charging of each rechargable transmitter.
  • Transmitters with a NiMH battery as well as 2 x2 NiMH batteries in the beltpack transmitter compartments can be recharged.
  • The charging status before start of charging is irrelevant. The batteries , however, that are charged in the same charging compartment should have the same capacity and the same charging state, because otherwise the battery that is higher discharged will not be recharged completely which can result in a deep discharge of the battery when the transmitter is in use again.
  • A microcontroller monitors the battery voltage during the complete charging time.
  • Significance levels are integrated such as dU-recognition and safety timer.
  • Charging time depending on capacity: 2 to 3 hours.
  • Status lights with each charging compartement display the appropriate charging state.

Application

The WA-CD charger provides four charging compartments for charging the rechargeable batteries inside the TG 1000 Beltpack, TG 1000 Handheld, TG 500B, TG 500H and Quinta TH transmitters. The rechargeable batteries remain inside the transmitters while charging. Furthermore the charging compartments for the beltpack transmitter provide options for charging 2 x2 NiMH batteries.

Note: NiMH batteries require approx. 3 to 8 charging/discharging cycles until they reach their maximum capacity.

Controls and indicators

  1. Charging compartment for handheld transmitter
  2. Charging light
  3. Combined charging compartment for beltpack transmitter and individual NiMH batteries
  4. Charging light
  5. DC power connection
  6. Ethernet connection for the communication with media control systems (TCP-IP based protocol)
  7. IP reset button (reset of the standard IP address)

Power connection

  • Mount the appropriate power plug to the power adaptor.
  • Connect the power adaptor to the charger and to the mains.
  • The charger provides no separate on/off switch and will start up automatically.
  • The charging lights of the battery compartments will illuminate white to indicate the ready operating status of the device.

How to charge the transmitter

  • Put the handheld or beltpack transmitter or the NiMH batteries in the charging compartments as indicated in the drawing. If the transmitter is turned on, it will be turned off automatically. Make sure to insert the NiMH batteries into the charging compartments as indicated by the +/- marks.
    Important: Before charging please make sure that there are not non- rechargeable alkaline batteries in the transmitter. The simultaneous of different batteries (alkaline and NiMH) in one transmitter is not suitable for operating the transmitter, furthermore these transmitters should not be charged, because transmitter and charger could be damaged. In this case the guarantee will be invalidated.

  • Before charging the device performs a so-called cell type detection. Even after the start of charging another security mechanism checks the first minute of charging, if the transmitter is equipped with rechargeable batteries. If there are no rechargeable batteries inside the transmitter, the charging process is not started or interrupted and the error is displayed by flashing red.

Note: In the picture you can see the Quinta TH handheld transmitter and the TG 1000 Beltpack transmitter. Instead of the Quinta TH you can also recharge the TG 1000 handheld transmitter.

Charging indicators

Each charging compartment is controlled separately. The appropriate indicators display the charging process.
Indicator illuminates white . . . . . . . . . . The charging compartment is ready for operation.
Insert the transmitter. Indicator illuminates red . . . . . . . . . . . . The battery cells are checked.
Indicator is flashing green . . . . . . . . . . . The batteries are being charged.
Indicator illuminates green . . . . . . . . . . The batteries are fully charged.
Indicator is flashing red . . . . . . . . . . . . Error. The charging process is not started or interrupted.
All indicators are flashing rapidly red . . . Severe error. Do not use the charger!

Note:

  • If an indicator is flashing red, remove the appropriate transmitter from the charging compartment and check, if there are alkaline batteries inside the transmitter or if the NiMH have been inserted incorrectly. Should the flashing persist even when using NiMH batteries, please check if the batteries are already fully charged. If not, the batteries are defective and must be replaced.
  • Should all the indicators flash rapidly red, no matter if there are transmitters in the charging compartments or not, there is a severe error. Disconnect the charger from the mains and check if there is a metallic object in the charging compartment. If yes, remove the object and connect the charger to the mains again. Should the indicators still flash rapidly, there is a defect, which the user cannot fix. In this case, please contact an authorised beyerdynamic dealer.

Network connection / reset IP address

  • If required, connect the Ethernet port to a media control system.
  • The default IP address is: 192.168.0.100
  • The IP address can be adapted to the existing network with appropriate commands.
  • If necessary, you can reset the IP address to the default address again by using the IP reset button.
  • You will find detailed information on the reset of the IP address in the separate manual about the communication with media control system (remote communication). Refer also to: www.beyerdynamic.com

Firmware update

  • The Ethernet port is also used for a firmware update of the WA-CD charger. You will find all the information you need at: www.beyerdynamic.com

Maintenance

  • For cleaning use a dry cloth only.
  • In order to ensure a proper function of the charger, keep the charging contact clean. Use a lint-free soft cloth moistened with alcohol or spirits to clean the charging contacts from time to time.

Service

Servicing must be carried out by qualified service personnel only. Dismantling the charger yourself will invalidate the guarantee.

Technical specifications

WA-CD charger
Charging current . . . . . . . . . . . . . . max. 1240 mA
Time of charge. . . . . . . . . . . . . . . . 2 to 3 hrs. (depending on the charging state of the battery)
Dimensions (W x D x H) . . . . . . . . . approx. 175 x 139 x 70 mm
Weight (without power adaptor) . . . . approx. 1125 g
Ambient temperature . . . . . . . . . . . 0 to +40 °C

CA2458 power adaptor
Output voltage. . . . . . . . . . . . . . . . 15 V DC
Current . . . . . . . . . . . . . . . . . . . . . 1600 mA
Input voltage . . . . . . . . . . . . . . . . . 100 – 240 V AC 50 / 60 Hz

EC-DECLARATION
OF CONFORMITY

Application of Council directive:
2004/108/EC
Electromagnetic Compatibility
2006/95/EC
Low Voltage Directive

Standards to which Conformity is declared:
EN 61 204-3: 2009-10  EMC
EN 301 489-1: 2011-09  EMC
EN 60 950-1: 2014  Safety

Manufacturer’s Name: beyerdynamic GmbH & Co. KG
Manufacturer’s Address: Theresienstrasse 8, 74072 Heilbronn, Germany
Type of Equipment: Charging Device
Model Numbers: WA-CD

I, the undersigned, as an employee of  beyerdynamic, hereby declare that the equipment specified conform to the above Directive and Standards.

Manufacturer’s Signature:
Full Name: Ulrich Roth
Date: 1. April 2015
Position: Director of R&D

beyertynamic GmbH & Co, KG
Theresienstr. 8. 74072 Heilbronn ‘Germany . Phone + 49 7131 617-0. Fan + 49 7131 617-224 . E-Mail [email protected], www.beyerdynamic.com
Marageng Owector: Wolfgang Luckhardt . Charman of the Supervisory Board: Prof. Wolf M. Nietzer, MBA LLM.
Registered in Stuttgart . HRA 101400 . Venve Heiltronn . VAT No. DE 146 795 43 ILM 40 10118 C0000 3 . Tar No. 65211/71002 . WEEE-Reg No DE 76451448
Kreisaparkasse Heilbronn Set Code 620 50000 Acct. No. 030 702 IBAN DE69 6208 0000-0000 030702 SIC HEISDE 66
Deutsche Bank AG Hetlbrann Sort Code 620 7008) «Acct. No.0 186304 (BAN DE&S 6207 0081 0018630400 BIC DEUTDE SS 620
Postbank Stuttgart Seet Code 600 100 70 Acct, No. 70685-703 IBAN DES3 6001 0070 0070 6857.03 BIC PENKDEFF

DECLARATION OF CONFORMITY

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. and (2) This device must accept any interference received, including interference that may cause undesired operation.

Manutacturer:
beyerdynamic GmbH & Co. KG
Theresienstrasse 8
D- 74072 Heilbronn, Germany

U.S. Responsible Party:
beyerdynamic, Inc.
56 Central Avenue
Farmingdale, NY 11735, USA

Contact Person:
Wolfgang Luckhardt, Managing Director
Phone: Tel. (631) 293 3200
Fax: (631) 293 3288

Model/Type: Charging Device
Model Numbers: WA-CD
Classification: Class B Digital Device

We hereby declare that the equipment bearing the trade name and model number specified above was tested conforming to the applicable FCC rules under the most accurate measurement standards possible and that the necessary steps have been taken and are in force to assure that production unit of the same equipment will continue to comply with the Commission’s requirements.

Manufacturer’s Signature: April 1, 2015, U. Roth, Director of R&D
Responsible Party’s Signature: April 1, 2015, W. Luckhardt, General Manager

beyerdynamic GmbH & Co. KG
E-mail: [email protected]| TheresienstraBe 8
74072 Heilbronn, Germany| Tel. +49 7131 617-0
Fax +49 7131 617-224
---|---|---

www.beyerdynamic.com
beyerdynamic GmbH & Co. KG
Theresienstraße 8 • 74072 Heilbronn • Germany
Phone +49 7131 617-300 • [email protected]
For further distributors worldwide, please go to www.beyerdynamic.com
Non-contractual illustrations. Subject to change without notice.
Weitere Vertriebspartner weltweit finden Sie im Internet unter www.beyerdynamic.com
Abbildungen nicht vertragsbindend. Änderungen vorbehalten.
DE-EN-FR 3 / WA-CD / 651.613 (04.19)

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

beyerdynamic User Manuals

Related Manuals