AIPHONE WB-HA Emergency Video Door Station Instruction Manual
- June 13, 2024
- AIPHONE
Table of Contents
AIPHONE WB-HA Emergency Video Door Station Instruction Manual
INSTRUCTIONS
The WB-HA wall box comes with “ASSISTANCE” in reflective blue lettering on
both sides of the box. A blue beacon/strobe light is mounted on top in a
vandal resistant enclosure.
The WB-HE wall box comes with “EMERGENCY” in reflective red lettering on both
sides of the box.
A blue beacon/strobe light is mounted on top in a vandal resistant enclosure.
The WB-HA and WB-HE are made of 12-Gauge stainless steel and are weather/vandal resistant. The narrow 4″ depth of the wall box allows it to meet all ADA mounting requirements. The blue beacon/strobe light requires a 24V DC power source, not included. Each box includes a UL Listed electrical box for installing an AC outlet, and a bracket to install a power supply internally. Compatible emergency /assistance sub stations include the IX-DVF- 2RA, IX-DVF-RA, IX-SSA-2RA, IX-SSA-RA, IS-DVF-2RA*, IS-SS-2RA-R, and IS- SS-RA R.
- Stations available with French signage option. Please visit our website for more information (www.aiphone.com/home).
WB-HA
Wall Box with Hooded Light and Blue Assistance Lettering
WB-HE
Wall Box with Hooded Light and Red Emergency Lettering
MOUNTING/WIRING
The WB-HA/WB-HE wall box comes pre-assembled with the beacon/strobe light and the enclosure attached. Mount the box to the wall, then wire the beacon/strobe light, power, and intercom sub station. Two screws are provided for mounting the power supply bracket to the internal bracket. Complete the installation by mounting the intercom sub station to the wall box. See below for additional information
Secure the wall box to any flat surface using mounting hardware suitable for the surface you are mounting to. Top mounting holes are 4-¼” apart and top to bottom mounting holes are 12″ apart. There are 3 knockouts on the back and 2 underneath for routing wire.
Connect the red and black wires from the beacon/strobe light to a 24V DC power
source. Red to positive and black to negative. Connect the white trigger wire
to the N/O side of relay 1 or 2 on the sub station. Connect the common of
relay 1 or 2 to the positive of the 24V DC power source. See the sub station’s
installation manual for its complete wiring and dip switch setting options.
Relay 1 connection is shown in example above.
Relay 1 must be enabled during the station programming process.
SPECIFICATIONS
Surface box:
- Mounting: Surface mount directly to wall
Mounting Height: 48″ AFF for camera to be at 60″ 44″ AFF for call button to be at 48″
Material: 12-Gauge Stainless Steel
Color: Polished Stainless Steel
Dimensions: 27″ H x 10-13⁄16″ W x 4″ D
Beacon/strobe light:
- Voltage: 24V DC
- Current: 200mA
- Wiring: Black: Ground
- Red: +24V DC
- White: Trigger
- Operating Temp: -40°F to 149°F