HOT-STEAM SGB600 SGB Gravity Fed Iron Instruction Manual
- June 13, 2024
- HOT-STEAM
Table of Contents
HOT-STEAM SGB600 SGB Gravity Fed Iron
WARNING
Before attempting to troubleshoot the iron, turn off and unplug the iron from the power supply. Close the valve on the Water Tank and disconnect the hose from the iron. Wait for the iron to cool down.
Technical Support Steps
- Hold and slide up the metal ring, then
- Remove the dial screw and dial spring
- Remove screws(3) and gently open and detach from the outer cover set, then the dial housing the outer cover
- Inspect and make sure to remove
- Make sure to properly tuck in all wires
- Gently install a new outer cover and lock all broken pieces from inside of the iron in between the covers before closing both covers in place with the metal ring
- Verify the thermostat stem is centered
- By loosening screw(2) the cover can
- Repeat steps 6, 7, and 8 until the stem If not, remove the cover and make adjustments by moving slightly up, and down, and left, and right are successfully centered. Tighten the outer cover screws(step 3) and then the dial set (step 2)
Copyright ©2021 Hot-Steam All rights reserved
For additional assistance contact Hot-Steam® Technical Support at
631-393-2811 or support@hot-
steam.com
Read User Manual Online (PDF format)
Loading......