UbiquiSTAT 202309 Commercial BACnet Controller Installation Guide
- June 13, 2024
- UbiquiSTAT
Table of Contents
- 202309 Commercial BACnet Controller
- Introduction
- Opening the UbiquiSTAT
- Mounting the UbiquiSTAT
- 6 sheet metal screws, either over a 2″ x 4″ or 4″ x 4″ junction box, or
- Powering the UbiquiSTAT
- UbiquiSTAT Wiring Connections
- Assembling the UbiquiSTAT
- Touch Screen Interface
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Installation Manual
UbiquiSTAT
Commercial BACnet Controller
202309 Commercial BACnet Controller
Model Number Definitions – A Key to Understanding UbiquiSTAT Series Model
Versions
TCS offers 16 different UbiquiSTAT versions based on four models: the US4010,
US4020, US4040, and US4050 (refer to the UbiquiSTAT Product
Data sheet for more
information on the specific features of each model).
Each UbiquiSTAT series is represented by the following color
icons:
Each model in the series is available in several versions which can include
wireless capability and an on-board dehumidification sensor. These versions
are identified in the color icons following the code below:
Introduction
Congratulations on choosing the UbiquiSTAT™ room controller! The UbiquiSTAT
series of controllers are feature rich, multifunction touchscreen devices
providing extensive controls across a wide range of HVAC applications.
This manual covers all 16 variations of Ubiquistats including wired, wireless,
and built-in dehumdification. It includes all the information necessary to
install and wire your UbiquiSTAT room controller. It includes a breakdown of
the input and output wiring for each type of connection.
After installing your UbiquiSTAT, refer to the UbiquiSTAT Quick Setup
Guide for instructions on the basic setup of the device. Refer to
the UbiquiSTAT Configuration Guide for instructions
on configuring the device, the communications network and other devices
connected to this controller. Refer to the UbiquiSTAT BACnet Explorer
Guide for advanced information on using the built-in BACnet Explorer to
edit the device’s BACnet programming objects directly.
If you have any questions regarding your UbiquiSTAT room controller, do not
hesitate to contact TCS Technical Support at
800-288-9383, ext. 2. Our Technical
Support Department hours are Monday – Friday, 7:00 a.m. to 7:00 p.m. (CST).
Opening the UbiquiSTAT
The UbiquiSTAT consists of a base containing wiring terminal blocks and
relays, and a front cover containing the touchscreen and all other circuitry.
It is shipped unassembled. Each base and cover pair are serialized together;
if you are installing multiple UbiquiSTATs, do NOT mix and match bases and
covers.
To remove the UbiquiSTAT cover once assembled, insert a small plastic pry tool
or flathead screwdriver between the front cover and base on the bottom of the
thermostat. Carefully run the tool along the seam until the halves separate.
Mounting the UbiquiSTAT
Mount the base of your UbiquiSTAT room controller on a vertical wall using two
6 sheet metal screws, either over a 2″ x 4″ or 4″ x 4″ junction box, or
directly to the wall. For best results, select an interior wall that
represents a normal room environment, at a height of about 48″ from the floor.
Mount the unit in a location which is accessible for adjusting settings.
For best temperature measurement accuracy, avoid areas that are exposed to
direct sunlight, unusual heating or cooling sources, open doors and windows,
unventilated locations, and hot or cold air from diffusers. If you are using a
remote room sensor, mount it in the same manner.
Powering the UbiquiSTAT
The UbiquiSTAT is powered from 24 VAC +15%/–5% and draws up to 10VA. If wiring
for communications, you must use dedicated power (transformer) to the unit.
Several TCS controllers may be powered from the same transformer, provided the
transformer has sufficient power and you maintain proper polarity. While the
UbiquiSTAT may be powered from the HVAC unit controller, using a dedicated
power source will avoid any potential ground loop issues between equipment
transformers.
When the UbiquiSTAT is used as a stand-alone thermostat without
communications, the equipment transformer may be used to power it. To do this,
install a jumper between the “R” (Packaged Unit Terminations) and “+24”
(Power) terminals. The “–24” (Power) terminal must then be connected to the
common side of the equipment transformer.
UbiquiSTAT Wiring Connections
The input/output terminals on the UbiquiSTAT utilize de-pluggable terminal
blocks, with either two or three poles. Refer to the color-coded diagram
below, which indicates which terminations are active on the various
models.
Power
Connect the power source using 18AWG two-wire twisted, stranded copper wire.
NOTE: Do not connect to 120VAC. When multiple TCS/Basys Controls devices
are using a single transformer, be sure to maintain the polarity of the power
wiring. All TCS devices are half-wave rectified and have common return
paths.
Optional: When used as a standalone thermostat with no communications,
you can power the unit via the HVAC unit’s transformer. To do this, install a
jumper connecting the “R” and “+24” terminals. The “–24” terminal must then be
connected to the common side of the unit transformer.
RS-485 Port
For communication wiring, use 22AWG three-wire twisted, stranded shielded
copper wire. Must run separately.
Packaged Unit Terminations
Packaged unit signals may be up to 28VAC from the equipment
terminations.
Time Clock Output
The Time Clock Output is an unpowered, isolated pair of relay contacts.
Connect an external device that operates with a schedule based on room
occupancy, such as an outdoor air damper, exhaust fan, or a
dehumidification/reheat unit. Use 18 – 22AWG two-wire twisted, stranded
shielded or unshielded wire.
Analog Outputs
Connect 4 – 20mA, analog output devices using 18 – 22AWG two-wire twisted,
stranded shielded or unshielded wire.
Connected actuators, motors, or drives must be powered separately from the
UbiquiSTAT. If you desire a voltage output, use an included 500Ω
resistor.
Digital Inputs
Digital inputs are used to receive status signals such as filter status, fan
status, etc. Use unpowered dry contacts only with 18AWG two-wire twisted,
stranded shielded or unshielded wire.
Temperature Inputs
Connect 1000Ω PtRTD temperature sensor inputs (range of -40ºF to 160ºF) using
18AWG two-wire twisted, stranded shielded wire, maximum 250 ft. length.
Sensors can be used for remote room temperature, discharge air temperature,
outdoor air temperature or mixed air temperature. Sensor wires should be kept
at least five feet from live voltage wiring.
NOTE: When using remote sensors, the unit may need to be calibrated See
the UbiquiSTAT Configuration Guide for more
information.
Analog Inputs
Connect 0 – 20mA or 4 – 20mA analog inputs using 18AWG two-wire twisted,
stranded shielded wire. These inputs can be used for any current-based sensors
such as CO2 and humidity. Inputs can be two-wire or self-powered.
Assembling the UbiquiSTAT
Before assembly, check that no wiring interferes with the cover, and no bare
wires are exposed. Follow the instructions below. You can also refer to a
video illustrating the assembly process by clicking
here.
STEP 1 Match the orientation of the internal connectors.
The top connector runs horizontally and the bottom connector runs vertically.
STEP 2 Gently
seat the front cover onto the base, checking the alignment on all four sides.
STEP 3 Starting on the right side of the unit and using both hands, snap
all four corners of the cover into place. Do not force the cover onto the
unit!
If it does not easily snap into place, check to make sure the internal
connectors are properly aligned and reassemble the unit.
NOTES:
If the screen does not light up:
- Check that there is power to the base
- The internal connectors may not be fully engaged. Carefully remove the cover and reassemble
If the screen lights but relays or inputs/outputs are not working:
- The internal connectors may not be fully engaged. Carefully remove the cover and reassemble
Touch Screen Interface
The home screen provides at-a-glance system information and basic user
controls. The navigation automatically returns to the home screen and the
display dims after 10 minutes of inactivity (no touches detected).
No.| Description
(All models/versions unless otherwise indicated)
---|---
1| Room Temperature and Setpoints
2| DI Setpoint Setback Active Indicator
3| Information Text (from connected sensors)
4| Indoor Relative Humidity
5| Settings Menu
6| Status Screens
7| About Screen
8| Service Status Indicator
9| Display Banner (Device Name and Date/Time)
10| Fan Operation Indicator
11| System Status (Heating/Cooling)
12| Economizer Status
13| Dehumidification Status
14| Occupancy Status
2800 Laura Lane • Middleton, WI 53562 | 800.288.9383 |
www.tcsbasys.com
TCS Building Automation Systems
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>