Rheem HVAC Among Heat Pumps And Air Conditioners Instruction Manual
High Performance and Sustainability
Have Never Felt So Good
High Performance and Sustainability
Have Never Felt So Good
Keep consistently comfortable year-round with the Rheem® Endeavor™ Line of Heat Pumps and Air Conditioners. The Rheem Endeavor Line offers an excellent range of choices designed for lasting energy-efficient comfort that saves you money while delivering peace of mind.
1Registration is required for the conditional parts and unit replacement warranty (if applicable). For complete details of the limited and conditional warranties, including applicable terms and conditions, contact your local Contractor or go to Rheem.com for a copy of the product warranty certificate. 2Refer to the chart for specific warranty terms by product. 3Based on Internal R&D Testing, May 2022. Sound levels are also dependent on proper installation and location of outdoor product. 4Residential Building Electrification in CA: Consumer economics, greenhouse gases and grid impacts, April 2019. 5Applies to RP18AZ and RA18AZ models. 6Applies to the RP16AZ, RA16AZ, RA15AZ and WA15AZ models. 7Applies to the RP14AZ model and WP14AZ. 8Applies to RP14AZ, RA14AZ, RA13NZ, WP14AZ, WA14AZ and WA13NZ models. 9WiFi broadband internet connection required. Download the EcoNet® App from the App Store® or Google Play® to set up your EcoNet Smart Thermostat. Receipt of notifications depend on home WiFi set up. Amazon, Alexa and all related logos are trademarks of Amazon.com, Inc. or its affiliates. 10Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR® criteria. Ask your contractor for details or visit EnergyStar.gov. 11Applies to RP18AZ, RP16AZ, RA18AZ, RA16AZ , RA15AZ and WA15AZ models. 12SEER (Seasonal Energy Efficiency Rating) / EER (Energy Efficiency Ratio) / HSPF (Heating Seasonal Performance Factor): The higher the SEER / EER / HSPF rating, the more efficient the unit. 135-ton models feature a 3/8 in. condenser coil.
WP14AZ
Cooling Efficiencies up to: 14.3 SEER2/10.4 EER2
Heating Efficiencies up to: 7.6 HSPF2
Nominal Sizes: 11/2 to 5 Ton [5.28 to 17.6 kW] Cooling Capacities: 17.1 to
55.5 kBTU [5.0 to 16.3 kW]
Features and Benefits
- Fully Louvered Steel Cabinet: Features durable construction to add protection from yard hazards, weather corrosion
- Two-Stage Scroll Compressor1: Features two speeds (high and low) of cooling and heating, providing more precise temperature control, lower humidity and greater efficiency when compared to single stage compressors
- Inverted Reversing Valve: Allows for faster heat transfer with gravity assist shifting and reduced joint stress for increased reliability
- Easily Accessible Control Box : Ease of installation and serviceability
Heat Pumps
Accessories
Weighted Sound Power Level (dBA)
Unit Dimensions
CLEARANCES
Control Wiring
Application Guidelines
- Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc.
- Minimum outdoor operation air temperature for cooling mode without low-ambient operation accessory is 55°F (12.8°C).
- Maximum outdoor operating air temperature is 125°F (51.7°C).
- For reliable operation, unit should be level in all horizontal planes.
- Use only copper wire for electric connections at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
- Do not apply capillary tube indoor coils to these units.
- Factory-supplied filter drier must be installed.
Refrigerant Line Size Information
NOTES:
- Do not exceed 200 ft linear line length.
- Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit.
- Always use the smallest liquid line allowable to minimize refrigerant charge.
- Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
- Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.
NOTES:
- Do not exceed 61m linear line length.
- Do not exceed 30m vertical separation if outdoor unit is above indoor unit.
- Always use the smallest liquid line allowable to minimize refrigerant charge.
- Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
- Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.
Performance Data @ AHRI Standard Conditions – Cooling