Technical data

Supply voltage 220 – 240 V
Frequency 50/60 Hz
Maximum power consumption 550 W
Power supply cable length 1 m (F, G, J, I)
Dimensions (width x depth x height) 439 x 515 x 190 mm
Weight (incl. accessories/packaging) 7,35 kg
Surface material Glass SSG/stainless steel 1.4301
Cooktop extractor power levels 1 – 5, P
duct connection BORA Eco tube

Product Description

  • Minimalistic design
  • Intuitive sControl+ control
  • direct function selection
  • Minimum volume
  • Simple cleaning
  • Cleaning lock
  • The integrated grease drip pan
  • Genuine stainless steel grease filter
  • Compact size
  • Automatic extractor control

Scope of delivery

  • BORA Classic cooktop extractor All Black CKA2AB
  • BORA Classic air inlet nozzle CKAEDAB
  • BORA Classic grease filter unit incl. grease filter tray
  • BORA Classic control unit
  • height adjustment plate set
  • Communication cable CAT 5 (3 m)
  • Country-specific power supply cable (1 m)
  • Ferrite sleeve
  • Installation instruction Classic 2.0
  • Instruction manual Classic 2.0

Accessories

  • BORA Classic air inlet nozzle CKAEDAB
  • BORA Classic grease filter unit incl. grease filter tray CAFFE
  • BORA Classic inlay-frame CER

product- and planning instructions

  • The cooktop extractor CKA2AB is the central component and it contains the complete electronic controls for the overall BORA Classic 2.0 system. Operating the system or the individual components is not possible without the cooktop extractor.
  • The BORA Classic 2.0 system is controlled using the operating panel of the cooktop extractor CKA2AB.
  • Can be combined with all BORA Classic 2.0 cooktops
  • The worktop height and depth can be flexibly adjusted
  • Installation type: flush or surface-mounted
  • Possible exhaust ducting to the right and to the left
  • The fan can be positioned in the plinth area as a result of the low installation height (100 mm) (when using the ULS plinth fan only)
  • The Classic 2.0 control unit as a central connection point can be simply and compactly positioned in the plinth area
  • The connection between touch control and the Classic 2.0 control unit via a CAT 5 communication cable
  • The drawers and/or shelves in the floor unit must be removable for maintenance and cleaning purposes
  • The BORA Eco tube duct system is optimally tailored to the BORA cooktop extractors and guarantees 100% functionality and optimum performance
  • Use of an additional fan module is possible for very long or complex exhaust air channels
  • The Classic 2.0 cooktop extractor system can be combined with all BORA sockets

Minimum dimensions for installation

BORA CKA2AB Classic Cooktop Extractor - Fig7BORA
CKA2AB Classic Cooktop Extractor - Fig

Cut-out dimensions

BORA Classic 2.0BORA CKA2AB Classic Cooktop Extractor - Fig
1

Important planning instructions:

  • All dimensions from the front edge of the front cover
  • Cut-out dimensions tolerance +1- 2 mm.
  • Clearance of 1 mm should be planned between the built-in appliances
  • Clearance of 2 mm should be planned around the built-in appliances.
  • Please note the worktop manufacturer’s instructions with regard to the suitability of the worktop. Worktop cut-outs must be moisture-sealed using suitable means or, where necessary, fitted with a thermal insulator (e.g. in the case of Corian or HiMacs worktops).

Installation cut-outs

BORA Classic 2.0
Installation cut-out CKA2 with shallow silencer USDF + transition, flat round offset EFRV110/1 (kitchen counter 600):

BORA CKA2AB Classic Cooktop Extractor - Fig 2

Installation cut-out CKA2 with shallow silencer USDF+ transition, flat round offset EFRV110/1 (kitchen counter 700): BORA CKA2AB Classic Cooktop
Extractor - Fig 3

Installation cut-out CKA2 with round silencer USDR50 (kitchen island):
BORA CKA2AB Classic Cooktop Extractor - Fig 4

Installation cut-out CKA2 with shallow silencer USDF + bridge flat round straight EFRG/1 (kitchen island):

BORA CKA2AB Classic Cooktop Extractor - Fig5

Connection diagram

BORA Classic 2.0
BORA Classic cooktop extractor CKA2

BORA CKA2AB Classic Cooktop Extractor - Fig6

Position Description Note
1 Cooktop power supply cable Length 1,5 m
2 Power supply per cooktop L/N/PE min. fuse protection 1 x 16 A
3 CAT 5 communication cable Length 3 m
4 CAT 5 communication cable
5 USB-Port Only for updates or data export
6 Control unit power supply cable Length 1 m
7 Control unit power supply Fuse protection 1 x 16 A
8 Fan 1 power supply cable
9 Fan 1 control line
10 Fan 2 power supply cable
11 Fan 2 control line Not required with the ULIE
M Fan 2
12 Home-Out connection Maximum 250 VAC/30 VDC, 5 A
S 1 External switch contact E.g. window contact switch for operating in

exhaust mode with flues/fireplaces
13| Home-In connection| 12V DC / 100 mA
14| Connection cable Home-In|
15| External device| E.g. electrically operated wall sleeve
16| Power supply for external device|

Note: based on the cable range, the control unit can be installed freely or wall-mounted. The control unit must be accessible. The connection diagram shows the maximum connection options required and is for planning purposes only. The connection itself must be carried out by a qualified specialist based on the operating instructions.