BORA PKAS3FIG Pro Cooktop Extractor System with Integrated Fan Installation Guide
- June 9, 2024
- BORA
Table of Contents
BORA PKAS3FIG Pro Cooktop Extractor System with Integrated Fan
PKAS3
BORA Pro cooktop extractor system with integrated fan:
Technical data|
---|---
Supply voltage| 220 – 240 V
Frequency| 50/60 Hz
Maximum power consumption| 550 W
Power supply cable length| 2 m
Dimensions (width x depth x height)| 468 x 540 x 199 mm
Weight (incl. accessories/packaging)| 12.5 kg
Cooktop extractor power levels| 1 – 9, P
duct connection| BORA Ecotube
Product description
- Intuitive control knob
- Automatic cover flap
- Premium design
- Simple cleaning
- Integrated grease drip pan
- Genuine stainless steel grease filter
- Modular system
- Automatic extractor control
- Maximum storage space
- Integrated fan
Scope of delivery
- Cooktop extractor system with integrated fan PKAS3
- Control knob
- stainless steel grease filter
- Filter tray
- Maintenance tray
- cover flap
- connection cable for the control knob
- operating and installation instructions
- height adjustment plate set
- Mounting clamps
- Power supply cable with type E + F plugs
Accessories
- PKA1FF stainless steel grease filter
- PKA1VK cover flap
- PKA1FW filter tray
- UNLI type I power supply cable (AUS)
- UNLJ type J power supply cable (CH)
- UNLG type G power supply cable (GB-IE)
- UNLB type B power supply cable (PH)
- UNLH type H power supply cable (IL)
product- and planning instructions
- Suitable for use as a recirculation or exhaust system
- Compatible with all BORA Professional 3.0 cooktops and BORA Universal fan modules
- Use of an additional fan module is possible for very long or complex exhaust air channels
- The worktop height can be adjusted as necessary
- Worktop depth: ≥ 700 mm
- Installation type: flush or surface-mounted
- The drawers and/or shelves in the floor unit must be removable for maintenance and cleaning purposes
- The BORA Ecotube duct system is optimally tailored to the BORA cooktop extractors and guarantees 100% functionality and optimum performance
- The Professional cooktop extractor system can be combined with all BORA sockets
- Duct connection on the back of the appliance
- The device must not be installed above cooling devices, dishwashers, stoves, ovens, washing machines or dryers.
PKFI3
BORA Pro surface induction cooktop:
Technical data|
---|---
Supply voltage| 220 – 240 V
Frequency| 50/60 Hz
Maximum power consumption| 3.68 kW
Maximum power rating| 3.68 kW
Minimum fuse protection| 1 x 16 A
Power supply cable length| 1,5 m
Dimensions (width x depth x height)| 370 x 540 x 52 mm
Weight (incl. accessories/packaging)| 8.1 kg
Surface material| SCHOTT CERAN®
Cooktop power levels| 1 – 9, P
Size of front cooking zone| 230 x 230 mm
Size of rear cooking zone| 230 x 230 mm
Front cooking zone output| 2100 W
Rear cooking zone output| 2100 W
Front cooking zone power setting output| 3680 W
Rear cooking zone power setting output| 3680 W
Product description
- Intuitive control knob
- Oversized surface induction cooking zones
- Performance level display on the cooktop
- Variable heat retention function
- bridging function
- Childproofing feature
- Cooking zone timers
- Timer
- Demo mode
- Pause function
Scope of delivery
- Surface induction cooktop PKFI3
- 2 x control knobs
- 2 x connection cables for the control knobs
- Connection cable to the extractor
- operating and installation instructions
- mounting straps
- height adjustment plate set product- and planning instructions
- Rotation by 180° possible during installation
- Please note that induction-compatible cookware must be used on induction cooktops
- Ensure sufficient ventilation of the area below the cooktop.
- The device must not be installed above cooling devices, dishwashers, stoves, ovens, washing machines or dryers.
PKG3
BORA Pro gas cooktop
Technical data|
---|---
Supply voltage| 220 – 240 V
Frequency| 50 / 60 Hz
Maximum power consumption| 5.0 kW
Maximum power rating| 20 W
Minimum fuse protection| 1 x 0.5 A
Power supply cable length| 1,5 m
Dimensions (width x depth x height)| 370 x 540 x 73 mm
Weight (incl. accessories/packaging)| 11.5 kg
Surface material| SCHOTT CERAN®
Cooktop power levels| 1 – 9, P
Size of front cooking zone| Ø 240 mm
Size of rear cooking zone| Ø 200 mm
Front cooking zone output (power burner)| 850 – 3000 W
Rear cooking zone output (normal burner)| 700 – 2000 W
Size of front pan support| 270 x 270 x 25 / 50 mm
Size of rear pan support| 235 x 235 x 25 / 50 mm
Product description
- Intuitive control knob
- Variable heat retention function
- Sunken gas burners
- Automatic reignition
- Dishwasher-safe pan supports
- Childproofing feature
- automatic heat up function
- precise electronic control
- residual heat display
- Demo mode
Scope of delivery
- Gas cooktop PKG3
- 2 x control knobs
- 2 x connection cables for the control knobs
- 2 x cast iron pan supports
- Gas nozzle set G20/20 mbar natural gas
- Connection cable to the extractor
- operating and installation instructions
- height adjustment plate set
- mounting straps
- Adapter cylindrical-conical
- Seal
Accessories
- BORA gas nozzle set natural gas G20/10 mbar PKGDS2010
- BORA gas nozzle set natural gas G20/13 mbar PKGDS2013
- BORA gas nozzle set natural gas G20/20 mbar PKGDS2020
- BORA gas nozzle set natural gas G25/20 mbar PKGDS2520
- BORA gas nozzle set natural gas G20/25 mbar PKGDS2025
- BORA gas nozzle set natural gas G25/25 mbar PKGDS2525
- BORA gas nozzle set liquid gas G30/G31 28-30/37 mbar PKGDS3028
- BORA gas nozzle set liquid gas G30/G31 50 mbar PKGDS3050
- BORA Pro gas nozzle set liquid gas G31/G30 mbar PKGDS3130
- BORA Pro gas nozzle set liquid gas G31/50 mbar PKGDS3150
- BORA burner set PKGBS
- BORA pan support small PKGTK
- BORA pan support large PKGTG
Product- and planning instructions
- The gas connection tube must be provided at the installation site (thread diameter 1/2“ cylindrical)
- Ensure sufficient air supply below the gas cooktop. Either over the front of the body (opening cross-section > 50 cm²) or over the plinth area (opening cross-section > 150 cm²)
- Provide a return flow aperture (opening cross-section > 1000 cm² per air cleaning unit) for recirculation in the plinth area
- Please note the local regulations and connection requirements applicable to gas cooktops
- Please note the special installation and workmanship guidelines for the gas cooktop (see the operating and installation instructions)
- When operating a gas cooktop with a cooktop extractor, the gas flame can be affected (depending on the height of the power level on the cooktop extractor)
- The performance characteristics of the gas cooktop (e.g. heating times, efficiency, etc.) are affected by the cooktop extractor. The cooktop extractor also affects the heat input and distribution
- If the gas cooktop is used in a model with two cooktop extractors, it is to be installed at the side
- Rotation by 180° possible during installation
Minimum dimensions for installation
- Minimum dimensions for installation PKA3 + UESDFSL:
- Minimum dimensions for installation PKA3 + UESDRSL:
- Minimum dimensions for installation PKAS3 + EFBV90 + ULBF:
- Minimum dimensions for installation 2 PKAS3 (exhaust system):
Cut-out dimensions
Flush installation
Surface mounting
Important planning instructions:
- All dimensions from the front edge of the front cover.
- Cut-out dimensions tolerance +/- 2 mm.
- Clearance of 1 mm should be planned between the built-in appliances.
- Clearance of 2 mm should be planned around the built-in appliances.
- Please note the worktop manufacturer’s instructions with regard to the suitability of the worktop. Worktop cut-outs must be moisture-sealed using suitable means or, where necessary, fitted with a thermal insulator (e.g. in the case of Corian or HiMacs worktops).
Control knob
Appliance and installation dimensions
Bore holes
Bore hole examples
Connection diagram
BORA Pro cooktop extractor system PKAS3
Position | Description | Note |
---|---|---|
1 | Cable control knob – interface | Length 1 m |
2 | Automatic extraction system cable | Length 1 m |
3 | Cooktop power supply cable | Length 1.5 m |
4 | Power supply per cooktop: PKT3, PKC3, PKCB3, PKCH3 PKFI3, PKI3, PKIW3, | |
PKG3 | ||
L1/L2/N/PE min. fuse protection 2 x 16 A |
L/N/PE min. fuse protection 1 x 16 A
5| PKAS3/PKAS3AB power supply cable| Length 2 m (country-specific)
6| PKAS3/PKAS3AB power supply|
7| Fan 2 power supply cable|
8| Fan 2 control line|
9| Connection cable Home-In|
10| Power supply for external device|
11| External device| e.g. electrically operated wall sleeve
12| Home-In connection| 24V DC / 100 mA
13| Home-Out connection| Maximum 250 VAC/ 30 VDC, 2.5A
M| Fan 2|
S1| External switch contact| e.g. window contact switch for operating in
exhaust mode with flues
The connection diagram shows the maximum connection options required and is for planning purposes only. The connection itself must be carried out by a qualified specialist based on the operating instructions.