Antarctic-Star D4212B Portable Dehumidifier Instruction Manual
- June 13, 2024
- Antarctic Star
Table of Contents
Antarctic-Star D4212B Portable Dehumidifier
Thank you
Please keep this manual carefully for further reference!
Thank you for selecting our dehumidifier. Be sure to read this manual carefully before using it. Any questions, please contact the professional service for help.
CAUTIONS
Please read the operating instructions carefully before using your dehumidifier for the first time.
- Install the unit on flat and hard floor to diminish vibration or noise.
- Never immerse the unit in water or other liquids.
- Never operate the unit if the cable or other connector is damaged, or something abnormal may happen, please call customer service for help.
- Disconnect the unit from power supply when it is not in use, or before relocating or cleaning it.
- Operate the unit only at the voltage specified.
- The unit is for indoor use only. Don’t use it for other purpose.
- Do not put heavy objects on the appliance.
- Do not tip the unit to any side as spilled water may damage the appliance.
- Never insert any other object into the unit body to avoid any hazard or unit failure.
- Do not put the unit close to heat-generating devices or near flammable and dangerous materials.
- This appliance is not intended for use by persons (including children) with reducedphysical, sensory or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
- If the supply cord is damaged, it must be replaced by the manufacturer or its serviceagent or a similarly qualified person in order to avoid a hazard.
- The appliance must be positioned so that the plug is accessible.
- The appliance shall be installed in accordance with national wiring regulations.
- The ambient temperature range for the appliance is 41℉- 95℉.
Don’t try to repair, dismantle or remold such appliance, or it may make some damage. Even the change of power cord should be done by specially qualified person.
PARAMETERS
Model No. | OL12D-D023B |
---|---|
Power Supply | AC115V/60Hz |
Power Consumption/Current | 165W/1.8A@80℉,60%RH |
Power Consumption/Current | 195W/2.0A@86℉,80%RH |
Dehumidify Capacity | 9Pints/Day@65℉,60%RH |
Dehumidify Capacity | 13Pints/Day@80℉,60%RH |
Dehumidify Capacity | 24Pints/Day @86℉,80%RH |
Noise | ≤36dB(A) |
Full Water Quantity | 2.0L |
Refrigerant /Charge | R134a/3.70oz(105g) |
Recommend Room Size | 161-269 sq.ft |
Body Size | 10 x 8.5x 19.5 in |
Net Weight | 10.4kg/23 lbs |
FEATURES
- 24Pints/Day efficient dehumidification
- Three optional modes (AUTO,CNT,SLEEP)
- Compact and modern design
- Extremely quiet operation(36dB(A))
- Auto defrosting
PRODUCT DESCRIPTION
DIGITAL DISPLAY
OPERATRIONS
Power
In the standby state, press the power button to turn on, the operation
indicator light is on and the default fan speed is high, and the default
humidity is 50%. In the power-on state, press the power button to turn off,
the running indicator light goes off and the compressor stops immediately, and
then the fan shuts down after 30 seconds’ delay.
Modes
Auto mode – Continuously drying mode – Sleeping mode cycle, press once to switch the mode from one to another, the corresponding indicator lights up.
- Auto mode : When environmental humidity ≥ setting humidity +3%, the fan starts working and the compressor starts working after 3 seconds. When environmental humidity ≤ setting humidity -3%, the compressor stops working and the fan stops working after 30 seconds’ delay. Both fan speed and humidity can be adjusted in the auto mode.
- Continuously drying mode: The machine continues to run, but the humidity can not be adjusted.
- Sleeping mode: Touch the sleep button, the button lights up and the sleep function starts. After no operation in 10 seconds, all indicators turn dark gradually and the wind speed is automatically switched from high to low. Touch any button to wake up the indicator. Touch sleep button again to exit the sleeping mode.
When environmental humidity ≤ 57%,the compressor stops working and the fan shuts down after 30 seconds’ delay. When environmental humidity ≥ 63%, the fan starts working and the compressor starts working after 3 seconds. Fan speed and humidity can not be adjusted in the sleeping mode.
Timer
Press the timer button to set the 0-12 hour timing function. The interval
is1hour. Each time you press this button, the value increases 1 hour and then
the corresponding timing value is displayed on the screen. The setting
valueis“00” to cancel the timer function. The indicator turns out. After the
timer is set and completed, the timer LED is on during the timing period.
After the timing is over, the timer LED turns off automatically.
In the running state, set the time to turn off the machine;
In the standby state, set the time to turn on the machine.
Humidity Set
Touch the humidity button to check the current environmental humidity, touch
this button again and you can set the humidity. The range of target
humidityis30% – 35% – 40% – 45% – 50% – 55% – 60% – 65% – 70%- 75%- 80%. After
setting 3 seconds, the system confirms the input value and then the machine
exits the setting state, and returns to the current humidity. In the drying
mode, the target humidity cannot be changed.
Press and hold the humidity button for 3 seconds to display the current
ambient temperature.
Speed
High wind – Low wind cycle, press button once to switch and then the corresponding indicator lights up. In continuously drying mode, sleeping mode and defrosting period, the wind speed can not be changed.
Child-lock
Press and hold the button for 3 seconds to turn on/off the child-lock function.
Accessories
- Water Pipe 1pcs
- Instruction manual 1pcs
Water Tank Full Alarm
Water Tank Indicator
- When the tank is full for 5 seconds, it sets the alarm. The water tank indicator turns red and the unit buzzes for 5 times.
Clear the alarm
- When the buzz is on, press any button to stop it. The compressor and the fan shut down and all the functions freeze until the tank is emptied and back in right position.
Empty the tank
-
Grab the notch at the bottom of the tank and pull it out with both hands. Take it slowly and steadily in case of spilled water.
-
Empty the water.
-
Put the water tank back in position. The dehumidifier automatically starts working again.
MAINTENANCE
PRECAUTIONS
-
Do not remove the float out of the tank otherwise the dehumidifier can not start up
-
Ensure the water tank is in right position when putting it back, otherwise the dehumidifier cannot start up.
-
If the tank is dirty, wash it with cool/warm water. Do not use cleanser, steel balls, chemically treated dust proof cloth, gasoline, benzene, thinners or other chemical solvents in case of damage and leakage.
-
Continuous Drainage
-
Take out the water tank
-
Use a water hose to connect the water outlet.
-
Pass the water hose through the cutting hole in the tank and put the tank back.
For continuous drainage, the end of the hose should not be submerged in water to prevent it from being blocked or damaged.
-
-
Spacing
When the dehumidifier is in operation, make sure that the rear of the dehumidifier maintains a minimum spacing of 30cm as shown below.
CLEANING
-
Body Cleaning
Use a soft and slightly moist cloth to clean the dehumidifier body. -
Filter Cleaning
-
Remove the filter.
-
Use a vacuum cleaner to gently absorb the dust on the surface. If the filter is very dirty, wash it with water and a soft detergent and dry it thoroughly afterwards.
-
Put the filter back.
STORAGE
When not using the product for a long time and intend to store it, please pay attention to the following steps:
- Empty the water in the water tank and wipe the water droplets on bottom of inside machine.
- Collect the power cord and store it in the dry water tank.
- Clean the filter.
- Place the machine in a cool and dry environment.
TROUBLE SHOOTING
-
FUNCTIONING TEMP
41℉≤ Ambient Temp. ≤ 95℉
When the ambient temp is lower or higher than the functioning temp, the dehumidifier stops. When 41℉≤ Ambient temp.
≤ 60.8℉, the compressor automatically defrosts at intervals; during defrosting, the compressor stops and the fan keeps running. -
BEFORE CALLING FOR SERVICE
Before contacting professional service, please review the trouble shooting list that includes common occurrences that are not the result of a defect in workmanship or materials.
Problem | Possible Cause | Solution |
---|---|---|
Not working | No power supply | Connect to a functioning outlet and switch on. |
Water Full Indication Flashes | Drain water tank and reset it, or re-position |
the water tank to right place.
Room temperature ˂ 41℉, or ˃ 95℉| Self-Protection designed to protect the
unit.
Can not work under such temperature.
Bad functioning| Is the air filter clogged?| Clean the air filter as
instructed.
Is the intake duct or discharge duct
obstructed?
| Remove the obstruction from the discharge duct or intake duct.
No air intake| Is the filter clogged?| Clean the air filter as instructed.
Loud noise when running| Is the machine placed in the plat place?| Put the
machine on the plat ground.
Is the filter clogged?| Clean the air filter as instructed.
E2| Humidity sensor problem| Change a sensor.
LO| Environmental humidity is below 20%| The dehumidifier shuts down for self-
protection.
HI| Environmental humidity is above 90%
CL| Low temperature protection, the environmental temperature ˂ 41℉
CH| High temperature protection, the environmental temperature ˃ 95℉
Thank you for purchasing this product! If you have any questions about the product, such as missing parts, damaged products, product assembling, and operation, please contact us via Amazon Message or customer service number: 213-4467172 or 661-4358826
Customer Support
IMPORTANT
Please call our customer service department for any consulting:
213-4467172
661-4358826
(8:30am – 5:30pm P.S.T.)
DATED PROOF OF PURCHASE IS REQUIRED FOR WARRANTY SERVICE.
Address : 9733 Topanga Canyon Blvd. APT310, Chatsworth, CA 91311
Phone: 213-4467172 or 661-4358826
Documents / Resources
|
Antarctic-Star D4212B Portable
Dehumidifier
[pdf] Instruction Manual
D4212B Portable Dehumidifier, D4212B, Portable Dehumidifier, Dehumidifier
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>