CASAMBI CBU Master Bus Repeater Instruction Manual

June 13, 2024
CASAMBI

CASAMBI-LOGO

CASAMBI CBU Master Bus Repeater

FEATURES

  • CONVERTER+CASAMBl+BUS
  • REPEATER CASAMBI
  • Input: 230Vac
  • Command: APP CASAMBI
  • Signal converter from Casambi to DALI o DMX, in MASTER Variant
  • Signal repeater, in REPEATER Variant
  • Possibility to control DALI or DMX device, by Casambi APP
  • Extended temperature range
  • 100% Functional test- 5 Years warranty

PRODUCT CODE

CASAMBI-CBU-Master-Bus-Repeater-FIG- \(1\)

PROTECTION

    CBU-MASTER-OALI/DMX REPEATER
OVP Over voltage protection1
IFP Input fuse protection 1

TECHNICAL SPECIFICATION

  CBU MASTER & CBU REPEATER
Nominal Voltage 230Vac
Voltage Range 100…240Vac
Mains Frequency 50/60 Hz
Nominal Power @230V2 3Wmax
Power loss in standby mode <SOOmW
Storage Temperature min: -40 max: +60·c
Ambient Temperature2 min: -25 max: +60 •c
Protection grade IP66
Mechanical dimensions 90x90x65 mm
Casing material Plastic
Weight 88g
  Only for BUS DALI
--- ---
I out (only for DALI) 150mA
V out (only for DALI) 15V
  1. Only control logic protection
  2. Maximum value, dependent on the ventilation conditions.

TECHNICAL NOTE

Installation:

  • Isolate the mains supply before the installation or adjusting the switches. Installation and maintenance must be performed in the absence of AC Voltage.
  • Installation and maintenance must be performed only by qualified personnel in compliance with current regulations.
  • The product must be installed inside an electrical cabinet protected against overvoltages.
  • The external supply must be protected. The product must be protected from Fuse and/or Circuit Breaker with overcurrent protection correctly dimensioned
  • The product must be installed only in a vertical or horizontal position with the cover/ label pointing upwards or vertically; No other positions are allowed. Button-up positive is not permitted (downward label).
  • The use of the product in harsh environments could limit the output power.
  • Keep 23OV circuits {LV) and non-SELV circuits separate from safety extra low voltage {SELV) circuits and from all connections of this product.
    It’s absolutely forbidden to connect for any reason, directly or indirectly, the 23OV mains voltage to the bus or to other parts of the SELV circuit.

Command

  • The length and type of the connection cables at the BUS (DMX512, DALI or other) must comply with the specification of the respective protocols and regulations and they should be isolated from every wiring or parts at voltage not SELV. It is suggested to use double insulated shielded and twisted cables.
  • All the product and the control signal connect at the bus (DMX512, DALI, or other) must be SELV (the devices connected must be SELV or supply a SELV signal)
    WARNING: Do not compromise the correct functioning of the device, the product must not be In any way shielded and/or Installed Inside metal and aluminium boxes.
    As any other Casambl product, should not be placed In a metal enclosure or next to large metal structures. Metal will effectively block all radio signals which are crucial to the operation of the product.

MECHANICAL DIMENSIONS

CASAMBI-CBU-Master-Bus-Repeater-FIG- \(2\)

INSTALLATION

Install the product following the below scheme

CASAMBI-CBU-Master-Bus-Repeater-FIG- \(3\)

CBU-REPEATER-IP SETUP

CASAMBI SIGNAL REPEATER

Characteristics:

  • The CBU-REPEATER-IP is a Casambi Repeater.
  • The device receives a Casambi Bluetooth signal and repeats it.

Status Led:

  • The status of LED is fixed on to indicate the correct power connection to the device.

TYPE OF PROFILE

CASAMBI-CBU-Master-Bus-Repeater-FIG- \(6\)

CBU-MASTER-DALI-IP SETUP

CASAMBI SIGNAL CONVERSION INTO DALI PROTOCOL

CHARACTERISTICS:

  • The CBU-MASTER-DALI-IP is a Casambi to DALI Converter.
  • The device receives a command signal from Casambi APP and converts the signal into a DALI command. Send DT6 and DT8 command. See the following table “ADDRESS MAP – DALI” for reference of Casambi-DALI conversion addresses.

STATUS LED:

  • When the status of the LED is steady on, the Casambi module is configuring and addressing the SLAVE DALI devices connected to the bus.
  • When the LED status flashes quickly, the Casambi module is sending the command set via the Casambi APP to the SLAVE DALI devices connected to the bus.
  • When the LED status flashes slowly, it means the DALI bus is shorted.
  • When the LED status is off there is no communication in the DALI bus.

AUTOMATIC DETECTION OF SHORT CIRCUITS IN THE DALI BUS:

When the device detects a short circuit on the DALI bus, it automatically switches off the power of bus and the LED signal flashes slowly.
At 15 seconds after the detection of the short circuit, CSU-MASTER-DALI tries to reactivate the power supply of the bus. If the short circuit has been solved, the system returns to work correctly, otherwise the bus remains unpowered and cyclically, every 15 seconds, the device tries again to reactivate the power supply of bus.

NOTE: CSU-MASTER-DAU-IP do not need a DALI Bus power Supply.
At switching on, all channels are set at same value 254.

TYPE OF PROFILE

CASAMBI-CBU-Master-Bus-Repeater-FIG- \(7\) CASAMBI-
CBU-Master-Bus-Repeater-FIG- \(8\) CASAMBI-
CBU-Master-Bus-Repeater-FIG- \(9\)

CASAMBI-CBU-Master-Bus-Repeater-FIG- \(10\)

CASAMBI-CBU-Master-Bus-Repeater-FIG- \(11\)

CASAMBI-CBU-Master-Bus-Repeater-FIG- \(12\)

ADDRESSES MAP- DAU

FIXTURE AUTOMATIC
The Fixture “AUTOMATIC” of the CBU-MASTER-DALI-IP addressing automatically the devices connected to the DALI BUS.

CASAMBI-CBU-Master-Bus-Repeater-FIG- \(13\) CASAMBI-
CBU-Master-Bus-Repeater-FIG- \(14\) CASAMBI-
CBU-Master-Bus-Repeater-FIG- \(15\)

FIXTlJRE GROUP

With “Group” Fixture the CSU-MASTER-DALI-IP sends group commands. The SLAVE devices to be controlled correctly by these Fixture must be previously addressed and assigned to the desired group through a Master DALI.

CASAMBI-CBU-Master-Bus-Repeater-FIG- \(16\)

CASAMBI-CBU-Master-Bus-Repeater-FIG- \(17\)

The 8xW GROUP SPECIAL profile send SET POWER ON LEVEL and SET SYSTEM FAILURE LEVEL command at 255 (MASK). These commands are sent at the DALI bus when you change the profile, by Casambi APP. For Control Gear to receive these commands correctly, they must be connected to the DALI bus before changing profile.

CASAMBI-CBU-Master-Bus-Repeater-FIG- \(18\)

CBU-MASTER-DMX-IP SETUP

CASAMBI SIGNAL CONVERSION INTO DMX PROTOCOL

Characteristics:

  • The CBU-MASTER-DMX-IP is a Casambi to DMX Converter.
  • The device receives the command signal from Casambi APP and convert it into a DMX command.
  • See the following “CHANNELS MAP- DMX” table for the reference of the Casambi-DMX conversion addresses.

Status Led:

  • Status LED is fixed on when the Casambi command is right transmitted.
  • Status LED slowly flashes (1 flash per second), when the device is powered.

TYPE OF PROFILE

CASAMBI-CBU-Master-Bus-Repeater-FIG- \(19\)

CHANNEL MAP – OMX

CASAMBI-CBU-Master-Bus-Repeater-FIG- \(20\) CASAMBI-
CBU-Master-Bus-Repeater-FIG- \(21\) CASAMBI-
CBU-Master-Bus-Repeater-FIG- \(22\)Strobe Rate execute the functions of the strobe address of the control unit connected to the CBU-MASTER-DMX-IP. For example, if you connect the CBU-MASTER-DMX-IP to the DLD1248-4CV-DMX control unit, which is also set with the MRGB+ or MRGBW+ map, the Strobe Rate address has the following characteristics:

CASAMBI-CBU-Master-Bus-Repeater-FIG- \(23\)

For other devices check the behaviour of the device at the respective channel 6 of the DMX.

BLUETOOTH RANGE
The range depends a lot on the surroundings and materials or building obstacles, see the technical notes on page 3.

DISTRIBUTED BY Wired 4 Signs USA
+1 (865) 339 4956
info@w4susa.com

www.w4susa.com
7669 Clinton Highway, Powell, Tennessee, 37849

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals