Schneider Electric XVS96BMBN Electronic Alarm Instruction Manual

June 13, 2024
Schneider Electric

Schneider-Electric-logo

Schneider Electric XVS96BMBN Electronic Alarm

Schneider-Electric-XVS96BMBN-Electronic-Alarm-product

Product Information

Product Name AQT0470C
Manufacturer Schneider Electric
Country of Origin Indonesia
Year of Production 2021
UK Representative Schneider Electric Limited Stafford Park 5 Telford, TF3 3BL

United Kingdom

Product Usage Instructions

  1. Ensure that the product is connected to a power source.
  2. Refer to the user manual for specific installation instructions.
  3. To turn on the product, locate the power button and press it.
  4. Use the control panel or remote control to navigate the product’s settings.
  5. To adjust the volume, use the volume buttons on the control panel or remote control.
  6. For troubleshooting or additional information, refer to the user manual or visit www.se.com.

Dimension

Schneider-Electric-XVS96BMBN-Electronic-Alarm-fig-
\(1\)

Caution

EQUIPMENT DAMAGE
Turn off the power supply before working on this equipment.

Failure to follow these instructions can result in injury or equipment damage.

PART NAMES

  1. Terminal
  2. Waterproof gasket
  3. Installation screw (4mm/0.16 in thumbscrew)
  4. Installation bracket
  5. Main unit
  6. Front panel
  7. Locking screw hole
  8. Sound select switch
  9. Volume adjustment
  10. Panel door screw hole
  11. Panel door
  12. Terminal cover

Schneider-Electric-XVS96BMBN-Electronic-Alarm-fig-
\(2\)

INSTALLATION

  1. Panel
  2. Waterproof gasket
  3. Bracket
  4. Screw
  • Install the unit, referring to the mounting installation template and the sample drawings
  • After cutting the panel installation hole out, place the unit in the panel and hold it into place with the bracket. Hold the bracket evenly while tightening the mounting screws.
  • Install with the waterproof gasket included to ensure the waterproof protection rating.
  • Mount securely to a solid surface with minimal vibration.
  • Do not switch the power ON and OFF quickly. For a channel replay, allow a one to two second switching interval to prevent a delay in the start of sound.Schneider-Electric-XVS96BMBN-Electronic-Alarm-fig- \(3\)

WIRING

  • C1: Wiring N version XVS 96BMBN and XVS 96BMWN
    • (1) NPN Open Collector, Vc ≥ Rated Voltage, Ic ≥ 10 mA, COM: Negative
  • C2 : Wiring P version XVS 96BMBP and XVS 96BMWP
    • (2) PNP Open Collector, Vc ≥ Rated Voltage, Ic > 10 mA, COM: Positive
    • (3)Don’t connect C connection
    • Following = DC power, connect the different channel to = DC 12 V or 24V
  • C3: Wiring P version XVS 96BMBP and XVS 96BMWP with ~ AC power supply
    • (2) PNP Open Collector, Vc ≥ Rated Voltage, Ic ≥ 10 mA, COM: Positive
    • (4) Add an external – DC power supply:
      Voltage rating: 5…12 V – Minimum Power: 0.2 W
  1. Turn off the power supply when installing and wiring.
  2. Do not connect the signal wires to an external power source (between COM and
  3. Channels 1…4). Use a non-voltage external contact, like a switch or relay.
  4. The fuse is not supplied with the product and must be provided by the customer.
  5. Use UL-recognized fuses and fuse holders when required.
  6. Use IEC60127 fuses and fuse holders when required.
  7. Voltage fluctuation should be no more than 10%.
  8. Do not use it with a power supply that exceeds surge voltage (1kV 1.2 / 50 microseconds) and noise voltage (2kV 5 / 50 ns).

Schneider-Electric-XVS96BMBN-Electronic-Alarm-fig-
\(4\)

OPERATING USE

  • (1) 2.6 × 5 mm / 0.10 x 0.20 in tapping screw for plastic
    After connecting the power, the alarm will sound when an input signal is present. However, in the case of two signals starting simultaneously, the lower channel has first priority.

  • (3) Volume Adjustment :
    Open the front panel to locate the volume adjustment knob, and adjust to the desired level 0…90dB). The level is set for maximum upon shipment. Do not listen closer than 0.2 m at maximum sound level.

  • (4) Sound Group Selection
    Open the front panel to locate the select knob, and select the desired setting. Refer to the Table of Built-in sounds (chapter F) for the available sound group Selections.

    • Sound Group A to O:
      When selected, the bit input function will correspond to the external input signal, and the corresponding alarm will sound. If two signals start simultaneously, the lower channel will take first priority.

    • Sound Group P
      When selected, the input is controlled by a binary-coded decimal; and the corresponding melody/alarm will sound. Refer to the Table of built-in sounds, “Binary Mode” ( chapter F) for the settings.

    • Front Panel Locking Screw Stem :
      After the volume and group have been set, the front panel can be locked to prevent tampering. Close the front panel and use a 2.6 mm/0.10 in locking screw to secure the door ( screw not included).Schneider-Electric-XVS96BMBN-
Electronic-Alarm-fig- 5

CHARACTERISTICS

Model XVS 96BMBN / BP – XVS 96BMWN / WP
Rated Voltage AC/DC12V
Power Consumption 3.5W/3W
Rated Output 2W
Sound Pressure       * 1 ‘6~87d8(1m fian si:eaker, free adµslrrenlfian

Olorraximurn)
Sound Input Control| Bit Input: 4 Channels, Binary Input: 15 Channels
Rated Time| Continuous Operation
Operating Temperature Range| -20°c~50°C
Operating Atmosphere| 35%~85%R.H. (No Condensaion)
Protection Characteristics *2| IP54 (Dust, Water Spray Protection)

Color

| Body: Black

Front Panel, Front Door: Black (XVS96BM8’1<) White (XVS96BMW*)

Product Mass| 0.4Kg

  1. The sound pressure level written is the maximum level recorded. Sound levels may be due to different sounds, fluctuations in voltage, or even weather conditions.
  2. Rating for panel mount installation.

BUILT IN SOUNDS

Bit Mode (For AM Sound Group A to O Function)

Sound Group Channel Number • Melody/Alarm Name
  2
A Ashita ga aru sa
B Doorbell Chime
C Forbidden Play
D Doorbell Chime
E Doorbell Chime
F Doorbell Chime
G Amaryllis
H Doorbell Chime
  Timpani Melody
J Doorbell Chime
K Mary’s Lamb
L Emergency Bell
M Arcade Sound
N Timpani Melody
0 Arcade Sound
p Binary Mode (Refer to Table Below)

Sound Group A is set before shipment.

Binary Mode (For AM Sound Group P Function)

Channel Melody/Alarm Name Starting Sound Number
1 2 3
1 CH Doorbell Chime  
2CH Intermittent Beep
3CH Forbidden Play  
4CH Katiucha
5CH Mary’s Lamb  
6CH Camp Town Races
7CH Amaryllis  
SCH Mozart#40
9CH Timpani Melody  
10CH Arcade Sound
1 1 CH Ashita ga aru sa  
12CH Electrical Parade
13CH Sazae-san  
14CH Touch
15CH Emergency Bell  
  • Indicates when channel input is ‘ ON ‘

www.se.com.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Schneider Electric User Manuals

Related Manuals