FRICO Elztrip EZ300 Heavy Duty Panel Heater Instruction Manual
- June 13, 2024
- FRICO
Table of Contents
FRICO Elztrip EZ300 Heavy Duty Panel Heater
Product Information
- The Elztrip EZ300 is a local space heater designed to provide thermal comfort for people in premises. It is manufactured by Frico and can also be used for technical heating purposes.
- The product is not subject to the Ecodesign Regulation (EU) 2015/1188 when used in installations of a more technical nature, such as engineering/utility rooms, production processes, frost protection, etc.
- It is also not applicable to installations in vehicles, offshore, or outdoors.
Product Usage Instructions
- Before installing the Elztrip EZ300, the installer responsible for the installation should assess whether the Ecodesign Regulation is applicable or not.
- If the installation falls under the Ecodesign Regulation, follow the control solutions listed in the separate table provided in the user manual.
- If the installation does not fall under the Ecodesign Regulation, refer to the separate table for control solutions specifically designed for installations not covered by the regulation.
- Mount the Elztrip EZ300 according to the provided mounting instructions shown in Figure 1. Ensure proper wiring and consider using wires not supplied with the product.
- Follow all safety precautions and guidelines provided in the user manual during installation and usage of the Elztrip EZ300.
- Ecodesign Regulation (EU) 2015/1188 concerning local space heaters does not apply to all application areas.
- The Regulation applies when an installation is intended to provide thermal comfort for people in the premises.
- The Regulation does not apply to heating installations of a more technical nature e.g. in engineering/utility rooms, in production processes, frost protection, etc.
- The Regulation also does not apply to installations in vehicles, offshore or outdoors.
- Many of Frico’s products can be used as both local space heaters (as defined in (EU) 2015/1188) and for technical heating purposes.
- It is up to the installer responsible for the installation to assess whether the Ecodesign Regulation is applicable or not.
- Control solutions for installations not covered by the Ecodesign Regulation are listed in a separate table.
Dimension
- L /A/B
- [mm] [mm] [mm]
- __**EZ336** 1670 1200 235 __
- EZ345 2030 1500 265
Mounting
- Wires (not supplied)
- Ceiling
EZ300 [mm]
A | 120 |
---|---|
B | 250 |
C | 250 |
D | 700 |
E | 1800 |
Controls
Controls for installations not covered by the Ecodesign Regulation (EU) 2015/1188
EZ300 (IP44)
Item number| Type| Heat output| Voltage| Amperage|
Max. surface temperature| Dimensions LxHxW| Weight
---|---|---|---|---|---|---|---
| | [W]| [V]| [A]| [°C]| [mm]| [kg]
11070| EZ336| 3600| 230V3~/400V3N~| 9,0/5,2| 320| 1670x63x420| 19,8
11071| EZ345| 4500| 230V3~/400V3N~| 11,3/6,5| 320| 2030x63x420| 24,2
- Heat output
- Max. surface temperature
- Voltage
- Amperage
- Weight
Wiring diagrams
Control with thermostat and relaybox
Control by thermostat, relaybox and black bulb sensor
Control by relaybox with 3 step output control and presence detector
Control with thermostat, contactor and switch – for installations not covered by the Ecodesign Regulation (EU) 2015/1188