exodraft RS009-4-1 Smoke Extractor RS User Guide

June 13, 2024
exodraft

Exhaust fan/smoke extractor

 RS009-4-1 Smoke Extractor RS

exodraft RS009-4-1 Smoke Extractor RS

The Exodraft RS exhaust fan is a specially designed one Exhaust fan with a horizontal discharge. The exhaust fan is mounted on top of the chimney a negative pressure in the flue gas pipe and in the chimney. With its axial wheel it is particularly suitable for all types of exhaust gases or hotter Air. Thus is the Exhaust fan RS from Exodraft for all species from fuels suitable. Exodraft’s exhaust fans are designed for temperatures up to 250 °C in continuous operation made from cast aluminum. All screws and bolts are made of stainless steel.
The motor is a temperature-resistant, encapsulated asynchronous motor with closed and maintenance-free Ball bearings. It sits outside the air volume flow. A special cooling wing and cooling air slots ensure constant cooling of the engine. The cable is heat-resistant, strain-relieved and protected on the outside with an armored hose.
These measures lend to that Exhaust fan a high Operational reliability and a long service life Lifespan. The exhaust fan can be opened so that the chimney sweep can easily clean the chimney can. The discharge opening is equipped with a stainless steel grille as finger and bird protection.

Technical data

1. Connection cable 5. Cooling plate
2. Top 6. Support plate
3. Engine 7. Hinges
4. Axial wing 8. Locking screws
Typ rpm
--- ---
RS009-4-1 1400
RS012-4-1 1400
RS014-4-1 1400
RS016-4-1 1400
RS255-4-1 1400
RS285-4-1 1400

*Power consumption at an ambient temperature of 20°C The exhaust fan is continuously adjustable in all versions.
Protection class IP 54, insulation class F

Performance charts

RS009 bis RS016

exodraft RS009-4-1 Smoke Extractor RS - Dimension

RS255 und RS285

exodraft RS009-4-1 Smoke Extractor RS - Dimension 3

Sound data

Lw (dB)

| 125 Hz| 250 Hz| 500 Hz| 1000 Hz| 2000 Hz| 4000 Hz| 8000 Hz| Lp dB (A)
---|---|---|---|---|---|---|---|---
Typ
RS009-4-1| 54| 50| 47| 43| 38| 31| 25| 21
RS012-4-1| 64| 60| 55| 52| 48| 42| 34| 30
RS014-4-1| 75| 69| 65| 62| 57| 51| 44| 41
RS016-4-1| 81| 76| 72| 69| 64| 58| 52| 47

Tolerance +/- 3 dB
Lw = sound power level dB (reference: 1 pW)
Lp = sound pressure level dB (A) at a distance of 10 m from the fan with hemispherical sound distribution
Lp (5m) = Lp (10m) + 6dB
Lp (20m) = Lp (10m) – 6dB