MATelec AUSTRALIA FPC-35111 Power Distribution Boards Instructions

June 4, 2024
MATELEC AUSTRALIA

AUSTRALIA FPC-35111 Power Distribution Boards
Instructions

FPC-35111 Power Distribution Boards

POWER DISTRIBUTION BOARDS – DELUXEMATelec AUSTRALIA FPC-35111 Power
Distribution Boards 1

HARDWARE FEATURES

Enclosure:

  • IP54 rated, powder coated mild steel enclosure with removable gland plate

Protection

  • Pad-lockable mains power isolator switch
  • Circuit breaker protected low voltage control and input circuitry
  • Circuit breakers for individual pump isolation
  • Din rail-mounted terminal connections

Control & interface: 

  • Indicator lights for system enabled, individual pump run and fault
  • Selector switch for system enable/disable control

Inputs:

  • Single phase (230Vac) or three phases (400Vac) power supply
  • 24Vac digital input for float switch
  • 1 to 4x 24Vac pump run and fault inputs

Outputs:

  • 1 to 4x pump supply outputs
  • Master pump/system enable volt free output
  • BMS volt-free outputs for individual pump run and fault
  • 24Vac output for N.O. solenoid valve (Deluxe+ range only)

Included with the panel:

  • Pre-connected power and control cables for each pump

COMMON APPLICATIONS

  • Pressure pumping systems
  • Irrigation pumping · Building services

MODIFICATION OPTIONS

  • 316 stainless steel enclosure
  • Jockey pump/duty pump configuration
  • Door mount isolator with interlocking handle
  • Tank level meter

FUNCTION FEATURES

  • Provides constant power to variable speed drives
  • Compatible with many brands of motor mount variable speed drives
  • Pump enable/run signal from float switch input
  • The system enable/disable switch allows for control circuit pump isolation
  • In the event of low rainwater, pump fault, or power failure, the controller de-energizes the valve output, opening the valve for mains water use (Deluxe+ range only)

POWER DISTRIBUTION BOARDS – DELUXE RANGE

Code No of Pumps Phase / Voltage kW Rating Options Enclosure Size
FPC-35111 1 1 Phase / 230Vac -1.5 to -2.2 400x300x150mm
FPC-35131 1 3 Phase / 400 Vac -1.5 to -22 400x300x150mm
FPC-35112 2 1 Phase / 230Vac -1.5 to -2.2 400x400x200mm
FPC-35132 2 3 Phase / 400 Vac -1.5 to -22 400x400x200mm
FPC-35113 3 1 Phase / 230Vac -1.5 to -2.2 400x400x200mm
FPC-35133 3 3 Phase / 400 Vac -1.5 to -22 500x500x300mm+
FPC-35114 4 1 Phase / 230Vac -1.5 to -2.2 500x500x300mm
FPC-35134 4 3 Phase / 400 Vac -1.5 to -22 600x600x300mm+

Note: Enclosure sizes will increase as power rating increase
POWER DISTRIBUTION BOARDS – DELUXE+ (RAIN/MAINS) RANGE

Code No of Pumps Phase / Voltage Options Enclosure Size
FPC-35411 1 1 Phase / 230Vac -1.5 to -2.2 400x300x150mm
FPC-35431 1 3 Phase / 400 Vac -1.5 to -22 400x300x150mm
FPC-35412 2 1 Phase / 230Vac -1.5 to -2.2 400x400x200mm
FPC-35432 2 3 Phase / 400 Vac -1.5 to -22 400x400x200mm
FPC-35413 3 1 Phase / 230Vac -1.5 to -2.2 400x400x200mm
FPC-35433 3 3 Phase / 400 Vac -1.5 to -22 500x500x300mm+
FPC-35414 4 1 Phase / 230Vac -1.5 to -2.2 500x500x300mm
FPC-35434 4 3 Phase / 400 Vac -1.5 to -22 600x600x300mm+

Note: Enclosure sizes will increase as power rating increase

KW RATING OPTIONS

Code Suffix Power Rating
-1.5 1.5 kW
-2.2 2.2 kW
-3 3.0 kW
-4 4.0 kW
-5.5 5.5 kW
-7.5 7.5 kW
-11 11.0 kW
-15 15.0 kW
-18.5 18.5 kW
-22 22.0 kW

Additional kW ratings available on request
P: 1800 281 282
F: 1300 281 282
E: [email protected] 
W: www.matelecaustralia.com.au
Specifications are subject to change without notice
Images are a guide only and may differ from the actual product

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

MATELEC AUSTRALIA User Manuals

Related Manuals