Hydromaster BX4114-S2 Hot Tub Pump and Motor Owner’s Manual

June 13, 2024
HydroMaster

Hydromaster BX4114-S2 Hot Tub Pump and Motor

Product Information

The High Performance Spa Pump is designed for use in spas and requires a 120V power source. It is important to follow the safety instructions and installation tips provided in this manual to ensure proper usage and prevent any electrical hazards or damage to
the pump.

This pump must be installed by a licensed electrician or qualified spa technician in accordance with the National Electrical Code and all applicable local codes and ordinances. Failure to do so may result in injury, death, or property damage.

The pump must be connected to a grounded circuit, properly bonded, and protected by a Ground-Fault Circuit Interrupter (GFCI) to reduce the risk of electrical shock. Always disconnect power to the pump at the circuit breaker before servicing or inspecting the
pump.

It is essential to confirm the control system pump circuit voltage matches the pump’s voltage (110-120V) before installation. If unsure, consult with a professional.

Pump Wiring

2-Speed Setup:

  1. Turn off power before working on any electrical connections.
  2. Confirm pump circuit voltage matches pump (110-120V).
  3. Supply Red Wire: connect to Terminal H (high speed).
  4. Supply White Wire: connect to Terminal C.
  5. Supply Black Wire: connect to Terminal L (low speed).
  6. Supply Green/Ground Wire: connect with Ground Screw.

Note: Some spas may alternate the use of Red Wire for Low Speed and Black Wire for High Speed. In such cases, simply swap Red and Black wire terminal positions for correct high & low-speed control operation.

1-Speed Setup:

  1. Turn off power before working on any electrical connections.
  2. Confirm pump circuit voltage matches pump (110-120V).
  3. Supply Black Wire: connect to Terminal H.
  4. Supply White Wire: connect to Terminal C.
  5. Supply Green/Ground Wire: connect with Ground Screw.

Installation Tips

  1. Replace failing gasket seals or broken unions.
  2. Loosen the lowest union slightly after installation to bleed air and flood/prime the new pump, then retighten.
  3. Hand-tighten unions only, without a wrench.
  4. After installation is complete, operate the spa for a few minutes and observe for leaks or air locks.

Troubleshooting Tips

Symptom Possible Cause
Motor not running No power to pump
Water not pumping properly Blockage or air lock
High & low speeds reversed Red & black wires function opposite
H and L terminal positions Check for incoming wiring to pump
Circuit breaker on GFCI functioning properly
Pump inlet blockage
Debris in pump housing
Pump priming

IMPORTANT SAFETY INSTRUCTIONS

READ & SAVE THESE DIRECTIONS

  • WARNING: Pump must be installed by a licensed electrician or qualified spa technician in accordance with the National Electrical Code and all applicable local codes & ordinances. Improper installation will create an electrical hazard and risk of shock which could result in injury or death, or damage to property including fire.
  • WARNING: Risk of electrical shock. Must be connected to a grounded circuit, properly bonded, and protected by a Ground -Fault Circuit Interrupter (GFCI). Keep out of the reach of children to reduce the risk of injury.
  • WARNING: Always disconnect power to the pump at the circuit breaker before servicing the pump or making inspections. Failure to do so could result in death or serious injury due to electric shock.
  • ATTENTION!! This pump is designed for 120V operation (110-120 volts). Connecting to a 240V source will destroy motor and void warranty. Confirm control system pump circuit voltage prior to installation. Consult with a professional if in doubt.

PUMP WIRING

2-Speed Setup

  1. Turn off power before working on any electrical connections
  2. CONFIRM pump circuit voltage matches pump (110-120V)
  3. Supply Red Wire: connect to Terminal H (high speed)*
  4. Supply White Wire: connect to Terminal C
  5. Supply Black Wire: connect to Terminal L (low speed)*
  6. Supply Green/Ground Wire: connect with Ground Screw
    *NOTE: Some spas may alternately use Red Wire for Low Speed, and Black Wire for High Speed. In such cases, simply swap Red and Black wire terminal positions for correct high & low speed control operation.

1-Speed Setup

  1. Turn off power before working on any electrical connections
  2. CONFIRM pump circuit voltage matches pump (110-120V)
  3. Supply Black Wire: connect to Terminal H
  4. Supply White Wire: connect to Terminal C
  5. Supply Green/Ground Wire: connect with Ground Screw

INSTALLATION TIPS

  1. Replace failing gasket seals or broken unions
  2. Loosen lowest union slightly after installation to bleed air and flood/prime new pump, then retighten
  3. Hand-tighten unions only, without wrench
  4. After installation is complete, operate spa for a few minutes and observe for leaks or air locks

TROUBLESHOOTING TIPS

TROUBLESHOOTING TIPS

Symptom| Possible Cause| Check For

Motor not running

|

No power to pump

| Incoming wiring to pump
Circuit breaker on
GFCI functioning properly
Water not pumping properly|

Blockage or air lock

| Pump inlet blockage
Debris in pump housing
Pump priming
High & low speeds

function opposite

| Reversed red & black

wires

| H and L terminal positions

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals