Hydromaster BX4114-S2 Hot Tub Pump and Motor Owner’s Manual
- June 13, 2024
- HydroMaster
Table of Contents
Hydromaster BX4114-S2 Hot Tub Pump and Motor
Product Information
The High Performance Spa Pump is designed for use in spas and requires a 120V
power source. It is important to follow the safety instructions and
installation tips provided in this manual to ensure proper usage and prevent
any electrical hazards or damage to
the pump.
This pump must be installed by a licensed electrician or qualified spa technician in accordance with the National Electrical Code and all applicable local codes and ordinances. Failure to do so may result in injury, death, or property damage.
The pump must be connected to a grounded circuit, properly bonded, and
protected by a Ground-Fault Circuit Interrupter (GFCI) to reduce the risk of
electrical shock. Always disconnect power to the pump at the circuit breaker
before servicing or inspecting the
pump.
It is essential to confirm the control system pump circuit voltage matches the pump’s voltage (110-120V) before installation. If unsure, consult with a professional.
Pump Wiring
2-Speed Setup:
- Turn off power before working on any electrical connections.
- Confirm pump circuit voltage matches pump (110-120V).
- Supply Red Wire: connect to Terminal H (high speed).
- Supply White Wire: connect to Terminal C.
- Supply Black Wire: connect to Terminal L (low speed).
- Supply Green/Ground Wire: connect with Ground Screw.
Note: Some spas may alternate the use of Red Wire for Low Speed and Black Wire for High Speed. In such cases, simply swap Red and Black wire terminal positions for correct high & low-speed control operation.
1-Speed Setup:
- Turn off power before working on any electrical connections.
- Confirm pump circuit voltage matches pump (110-120V).
- Supply Black Wire: connect to Terminal H.
- Supply White Wire: connect to Terminal C.
- Supply Green/Ground Wire: connect with Ground Screw.
Installation Tips
- Replace failing gasket seals or broken unions.
- Loosen the lowest union slightly after installation to bleed air and flood/prime the new pump, then retighten.
- Hand-tighten unions only, without a wrench.
- After installation is complete, operate the spa for a few minutes and observe for leaks or air locks.
Troubleshooting Tips
Symptom | Possible Cause |
---|---|
Motor not running | No power to pump |
Water not pumping properly | Blockage or air lock |
High & low speeds reversed | Red & black wires function opposite |
H and L terminal positions | Check for incoming wiring to pump |
Circuit breaker on GFCI functioning properly | |
Pump inlet blockage | |
Debris in pump housing | |
Pump priming |
IMPORTANT SAFETY INSTRUCTIONS
READ & SAVE THESE DIRECTIONS
- WARNING: Pump must be installed by a licensed electrician or qualified spa technician in accordance with the National Electrical Code and all applicable local codes & ordinances. Improper installation will create an electrical hazard and risk of shock which could result in injury or death, or damage to property including fire.
- WARNING: Risk of electrical shock. Must be connected to a grounded circuit, properly bonded, and protected by a Ground -Fault Circuit Interrupter (GFCI). Keep out of the reach of children to reduce the risk of injury.
- WARNING: Always disconnect power to the pump at the circuit breaker before servicing the pump or making inspections. Failure to do so could result in death or serious injury due to electric shock.
- ATTENTION!! This pump is designed for 120V operation (110-120 volts). Connecting to a 240V source will destroy motor and void warranty. Confirm control system pump circuit voltage prior to installation. Consult with a professional if in doubt.
PUMP WIRING
2-Speed Setup
- Turn off power before working on any electrical connections
- CONFIRM pump circuit voltage matches pump (110-120V)
- Supply Red Wire: connect to Terminal H (high speed)*
- Supply White Wire: connect to Terminal C
- Supply Black Wire: connect to Terminal L (low speed)*
- Supply Green/Ground Wire: connect with Ground Screw
*NOTE: Some spas may alternately use Red Wire for Low Speed, and Black Wire for High Speed. In such cases, simply swap Red and Black wire terminal positions for correct high & low speed control operation.
1-Speed Setup
- Turn off power before working on any electrical connections
- CONFIRM pump circuit voltage matches pump (110-120V)
- Supply Black Wire: connect to Terminal H
- Supply White Wire: connect to Terminal C
- Supply Green/Ground Wire: connect with Ground Screw
INSTALLATION TIPS
- Replace failing gasket seals or broken unions
- Loosen lowest union slightly after installation to bleed air and flood/prime new pump, then retighten
- Hand-tighten unions only, without wrench
- After installation is complete, operate spa for a few minutes and observe for leaks or air locks
TROUBLESHOOTING TIPS
TROUBLESHOOTING TIPS
Symptom| Possible Cause| Check For
Motor not running
|
No power to pump
| Incoming wiring to pump
Circuit breaker on
GFCI functioning properly
Water not pumping properly|
Blockage or air lock
| Pump inlet blockage
Debris in pump housing
Pump priming
High & low speeds
function opposite
| Reversed red & black
wires
| H and L terminal positions
References
- SpaDepot.com | America's Favorite Hot Tub Supply Store
- SpaDepot.com | America's Favorite Hot Tub Supply Store