milwaukee L4 FMLED USB Rechargeable 800L Fixed Flashlight Instruction Manual

June 13, 2024
Milwaukee

Nothing but HEAVY DUTY

L4 FMLED USB Rechargeable 800L Fixed Flashlight

L4 FMLED
Original instructions

Picture section with operating description and functional description
Text section with Technical Data, important Safety and Working Hints and description of Symbols

milwaukee L4 FMLED USB Rechargeable 800L Fixed Flashlight -
fig

milwaukee L4 FMLED USB Rechargeable 800L Fixed Flashlight - fig
1milwaukee L4 FMLED USB
Rechargeable 800L Fixed Flashlight - fig 2

Dual function power button
Press firmly (click) -> on/off
Press firmly for 1.5 sec. -> cycle through the modes

TECHNICAL DATA

| L4 FMLED
---|---
Type| 10 W
Rated power input| 4 V
Battery voltage| Battery-Lamp
Luminous flux
High
Low| 800 lm
100 lm
Lighting time
High
Low| 2,0 h
10,0 h
Charging time| 120 min
Colour rendering index (CRI)| 80
Colour temperature| 4000 K
USB input| 5 V DC; 0,1 A – 2,1 A
Protection class|  IP67
Weight| 0,2 kg
Recommended ambient operating temperature| -18°C … +50 °C
Recommended ambient charging temperature| +5°C … +40 °C
Recommended battery types| L4B2, L4B3

WARNING! Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.

SAFETY INSTRUCTIONS BATTERY-LAMP

Warning: Do not direct the light beam at persons or animals and do not stare into the light beam yourself (not even from a distance). Staring into the light beam may result in serious injury or vision loss.
Don‘t use this tool in wet areas .
The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced.
SAFETY INSTRUCTIONS BATTERY
Only use Milwaukee Type L4B2, L4B3 rechargeable batteries. Remove the battery pack before starting any work on the appliance.
Do not dispose of used battery packs in the household refuse or by burning them. Milwaukee Distributors offer to retrieve old batteries to protect our environment.
Do not store the battery pack together with metal objects (short circuit risk).
Battery acid may leak from damaged batteries under extreme load or extreme temperatures. In case of contact with battery acid wash it off immediately with soap and water. In case of eye contact rinse thoroughly for at least 10 minutes and immediately
seek medical attention.
Warning! To reduce the risk of fire, personal injury, and product damage due to a short circuit, never immerse your tool, battery pack or charger in fluid or allow a fluid to flow inside them.
Corrosive or conductive fluids, such as seawater, certain industrial chemicals, and bleach or bleach containing products, etc., can cause a short circuit.

SPECIFIED CONDITIONS OF USE

The battery lamp can be used as lighting independently of a mains power supply.
Do not use this product in any other way as stated for normal use.

NOTES FOR LI-ION BATTERIES

Use of Li-Ion batteries
Batteries which have not been used for some time should be recharged before use.
Temperatures in excess of 50°C (122°F) reduce the performance of the battery. Avoid extended exposure to heat or sunshine (risk of overheating).
The contacts of chargers and batteries must be kept clean. For an optimum life-time, the batteries have to be fully charged, after used.
To obtain the longest possible battery life remove the battery pack from the charger once it is fully charged.
For battery storage longer than 30 days:
Store the battery where the temperature is below 27°C and away from moisture
Store the battery in a 30% – 50% charged condition Every six months of storage, charge the battery as normal. Transport of Li-Ion batteries
Lithium-ion batteries are subject to the Dangerous Goods Legislation requirements.
Transportation of those batteries has to be done in accordance with local, national and international provisions and regulations.

  • The user can transport the batteries by road without further requirements.
  • Commercial transport of Lithium-Ion batteries by third parties is subject to Dangerous Goods regulations. Transport preparation and transport are exclusively to be carried out by appropriately trained persons and the process has to be accompanied by
    corresponding experts.

When transporting batteries:

  • Ensure that battery contact terminals are protected and insulated to prevent short circuit.
  • Ensure that battery pack is secured against movement within packaging.
  • Do not transport batteries that are cracked or leak.
    Check with forwarding company for further advice

CHARGING

Plug your USB cable into a power source such as an AC wall adaptor, computer or car port.
The indicator light will display the charging status:
Red flashing: charging, 0-49% charged Orange flashing: charging 50-99% charged Green solid: 100% charged
Red/Green flashing: damaged or faulty battery  If the light indicator flashes red and green, check that the battery is fully seated into the bay. Remove the battery and reinsert. If the light continues to flash red and green, the battery may be extremely hot or cold, or wet. Allow the battery to cool down, warm up, or dry out and then reinsert. If the problem persists, contact a MILWAUKEE service facility.

FUEL GAUGE

The fuel gauge will display the battery life:
Red flashing: 0-3% remaining
Red solid: 3-10% remaining
Orange solid: 11-49% remaining
Green solid: 50-100% remaining

MAINTENANCE

Use only Milwaukee accessories and Milwaukee spare parts.
Should components need to be replaced which have not been described, please contact one of our Milwaukee service agents (see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered. Please state the machine type printed as well as the six-digit No. on the label and order the drawing at your local service agents or directly at: Techtronic Industries GmbH, Max-Eyth-Straße 10, 71364 Winnenden, Germany.

SYMBOLS

| Please read the instructions carefully before starting the machine.
---|---
**| CAUTION! WARNING! DANGER!)
| Do not stare at the operating light source.)
| Warning! Hot Surface! Do not touch!
| Class III electrical protection.
IP67| Protection class
| This tool is only suitable for indoor use. Never
expose tool to rain.
**
| Do not dispose of waste batteries, waste electrical and electronic equipment as unsorted municipal waste. Waste batteries and waste electrical and electronic equipment must be collected separately. Waste batteries, waste accumulators and light
sources have to be removed from equipment. Check with your local authority or retailer for recycling advice and collection point.
According to local regulations retailers may have an obligation to take back waste batteries and Waste electrical and electronic equipment free of charge. Your contribution to re-use and recycling of waste batteries and waste electrical and electronic
equipment helps to reduce the demand of raw materials.
Waste batteries, in particular containing lithium and waste Electrical and electronic equipment contain valuable, recyclable materials, which can adversely impact the environment and the human health, if not disposed of in an environmentally compatible manner. Delete personal data from waste equipment, if any.
| European Conformity Mark
| UK Conformity Mark
| Ukraine Conformity Mark
****| EurAsian Conformity Mark

Copyright 2023
Techtronic Industries GmbH Max-Eyth-Str. 10
71364 Winnenden
Germany
+49 (0) 7195-12-0
www.milwaukeetool.eu
Techtronic Industries (UK) Ltd
Parkway
Marlow SL7 1YL UK
(04.23)
4931 4708 46

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Milwaukee User Manuals

Related Manuals