Model………….. Vallox Delico KTD A
Document………………… D9520
Type…………………….. A279842-1
Valid from……………….. 01.11.2020
Updated…………………. 03.10.2022
Manual
The Vallox Delico KTD A cooker hood is designed to be used above the cooker
top, or as a general extraction valve in the kitchen.
The hood has a timer damper and a guard function.
VENTILATION CONTROL
The removal of cooking smells can be enhanced by using the adjustment damper
of the hood. Potential-free contact data and 230 V 4 A supply voltage are
provided of the position of the damper.
When Vallox Delico KTD A is connected to the joint extraction system of a
multi-storey building, a Vallox Smoke Limiter must also be installed.
USING THE COOKER HOOD
The cooker hood has a sliding part that can be pulled out of the cooker hood.
Pull the sliding part out of the cooker hood for maximal extraction capacity.
Front panel buttons
The front panel of the cooker hood has two buttons and two signal lights.
Position of the damper
The damper is opened by pressing the damper button (light turns on). The
damper is closed (light turns off) by pressing the damper button or
automatically after one hour (without a timer or 45-120 min when programmed).
In normal circumstances, the damper must be closed (the signal light is off),
which boosts the extract air flow from other premises.
The damper must be open (the signal light is turned on) when the user wants to
increase the extract air flow from the cooker hood e.g.
- when the cooker top or the oven is used for cooking
- when the load in the kitchen is exceptional e.g. due to the use of strong detergents or the presence of a large number of people.
Touch the button on the damper to open it and to start the timer. The damper
will close automatically within 60 minutes.
Cooker hood light
Turn the light on or off by pressing the light switch. The light is dimmable.
Adjust the brightness by pressing the light switch until the brightness is
adequate.
Selection button
The selection button is roughly 3 cm to the left from the damper button. The
selection button is not marked on the front panel.
CAUTION
- Neglecting the cleaning of the grease filter can cause a fire hazard.
- The outer surfaces of the hood can become hot when the cooker or the oven is turned on.
- Flaming is forbidden underneath the cooker hood.
- Always follow the instructions provided on adjusting the efficiency of ventilation.
- Enable a sufficient supply air flow into the room if the cooker hood and non-electric devices are used simultaneously.
Other functions
Guard function
The cooker hood has a guard function that is activated when the temperature of
the cooker hood exceeds +60 °C or after a sudden increase in temperature (> 8
°C/ min). In such a case, the damper of the cooker hood closes and all signal
lights of the cooker hood and the LED light will flash. If this kind of alarm
is noticed before fire damage, it can be acknowledged by pressing any of the
cooker hood buttons.
Pre-selection of light brightness
To modify the pre-selection of light brightness:
- Turn the light on and close the damper.
- Press the selection button for roughly 3 seconds until the setting mode signal light starts to flash.
- Adjust the brightness of the light by pressing the light button until the brightness is adequate.
- To save the setting, press the selection button for roughly 3 seconds until the setting mode signal light stops to flash.
To read about the other functions of the selection button, go to our website,
www.vallox.com.
WARNING
The unit is not intended for use by children under 8 or by persons with
reduced sensory, physical or mental capabilities, or whose lack of knowledge
and experience do not ensure safe operation of the unit.
Such persons can use the unit under supervision, or by following the
instructions of someone who is responsible for their safety. Do not let
children play with the unit or to clean or maintain it without supervision.
MAINTENANCE
Keep the cooker hood clean. Wipe outer surfaces regularly with water
containing a small amount of a mild detergent. Clean off any grease stains
immediately. Do not use abrasive or corrosive detergents or tools.
Keep the grease filter clean to ensure an adequate extract air flow. The
grease filter must be washed with warm water and detergent at least 1-2 times
a month.
Removing and mounting the grease filter Light
The cooker hood has a long-lasting LED lighting module (6.7 W). If the light
is not working, contact a servicing company.
- Pull the sliding part out of the cooker hood.
- Pull the locking device of the grease filter towards the front edge of the cooker hood while pulling the grease filter downwards until it comes off.
- Wash the grease filter and leave to dry.
- Mount the grease filter back in place. Push the front edge of the filter into the pins on the cooker hood, and click the rear edge in place.
NOTE
Ensure that the locking device points downwards.
INSTALLATION
CAUTION
The cooker hood must not be connected to a flue that is used for removing
combustion gases (e.g. from a wood- or gas-burning fireplace, cooker, or
stove).
CAUTION
Regulations on leading extraction air outdoors must be observed.
CAUTION
The power outlet used for the cooker fan must be easy to access.
CAUTION
The minimum distance of the bottom edge of the hood to an electric cooker is
400 mm and to a gas cooker 650 mm.
DIMENSION DIAGRAMS
EXTERNAL ELECTRICAL CONNECTION TO THE VENTILATION UNIT OR A ROOF FAN
CONTACT DATA:
GUARD FUNCTION:
NORMAL SITUATION = OPEN
ACTIVATED = CLOSED
HOUSE AUTOMATION:
NORMAL SITUATION = OPEN
ERROR SITUATION
(HOOD OR VENTILATION UNIT) = CLOSED
ACTIVATED GUARD FUNCTION = FLASHING
POSITION OF THE DAMPER:
DAMPER CLOSED = CONTACT OPEN
DAMPER OPEN = CONTACT CLOSED
TOTAL PRESSURE LOSS AND SOUND VALUES
Total pressure loss with standard ventilation (damper closed)
MEASURING AND ADJUSTING PERFORMANCE VALUES
Standard ventilation
The volume flow rate of
the air inside the cooker hood is measured with the damper closed and, where
required, adjusted based on the static pressure loss and the performance
scheme of the cooker hood.
- Measure the static pressure loss of the cooker hood by pushing the probe through the hole in the damper (see the figure).
- Determine the volume flow rate from the performance scheme based on the measured pressure and the number of open holes in the damper.
Adjustment:
- Cover the required number of holes in the damper with the magnetic strip that is delivered with the cooker hood.
Boost ventilation
The volume flow rate of the
air inside the cooker hood is measured with the damper open based on the
static pressure loss and the performance scheme of the cooker hood.
- Measure the static pressure loss of the cooker hood. The measuring point must be located 2 times the duct diameter above the outlet collar of the cooker hood (see figure).
- Determine the volume air flow based on the measured pressure and the performance scheme (with the damper open).
NOTE
If a Vallox Smoke Limiter has been installed in connection to the Vallox
Delico KTD A cooker hood, air flow adjustment must be completed in accordance
with the manual of the Smoke Limiter.
K VALUES
STANDARD VENTILATION
Adjustment position | Holes of the damper open | K value |
---|---|---|
2 | 2 | 0.5 |
3 | 3 | 0.6 |
4 | 4 | 0.8 |
5 | 5 | 1 |
6 | 6 | 1.1 |
7 | 7 | 1.3 |
8 | 8 | 1.4 |
Damper open | 4.9 |
www.vallox.com
Vallox Oy | Myllykyläntie 9-11
32200 LOIMAA | FINLAND