Rohnson R-893 Portable Air Conditioner User Manual
- June 13, 2024
- Rohnson
Table of Contents
R-893
Portable Air Conditioner User’s Manual
Introduction
Thank you for choosing this mobile air conditioner to provide you and your
family with all of the “Home Comfort” requirements for your home, cottage or
office. The appliance can be moved from room to room within your home and set-
up in just minutes.
It is a multi-functional room air exchanging, air-processing appliance,
designed to offer you the functions of: Air conditioner, Dehumidifying,
Independent Fan. The external static pressure at which the appliance was
tested 0Mpa.
This manual will provide you with valuable information necessary for the
proper care and maintenance for your new appliance. Please take a few moments
and read the instructions thoroughly. If properly maintained, your appliance
will give you many years of trouble-free operation.
Electrical Specifications
- All wiring must comply with local and national electrical codes and be installed by a qualified electrician. If you have any questions regarding the following instructions, contact a qualified electrician.
- Check available power supply and resolve any wiring problems before installation and operation of this unit.
- For your safety and protection, this unit is grounded through the power cord plug when plugged into a matching wall outlet. If you are not sure whether the wall outlets in your home are properly grounded, please consult an electrician. If supply cord is damaged, it must be replaced by the manufacture, its service agent or similarly qualified person to avoid hazard.
IMPORTANT SAFETY INSTRUCTIONS
To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow these basic precautions:
- Plug into a grounded 3 prong outlet.
- Do not remove ground prong.
- Do not use an adapter.
- Do not use an extension cord.
- Unplug air conditioner before servicing.
- Use two or more people to move and install air conditioner.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capability or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
- Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- If the supply cord is damaged, it must be replaced by the manufact
- The appliance shall be installed in accordance with national wiring regulations.
- The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Young children should be supervised to ensure that they do not place with the appliance.
- Correct Disposal of this product
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection, systems or contact the retailer where the product was purchased. They can take this product for environmentally safe recycling.
-
Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
The appliance shall be stored in a room without continuously operating ignition sources for example: open flames, an operating gas appliance or an operating electric heater.
Beware that refrigerant may not contain an odor. Do NOT pierce or burn. -
When the machine malfunctions, do not repair it yourself. Please contact a professional organization or a professional trained maintenance personnel or a service organization recommended by the supplier for repair!– The maximum refrigerant charge amount: 120g
Identification of part
- Control panel
- Signal Receptor
- Cold Air Outlet
- Remote Controller
- Transport Handle
- Air Outlet Hose
- Evaporator Air Intake
- Primary Drain Port
The
figures in this manual are based on the external view of a standard model.
Consequently, the shape may be different from that of the air conditioner you
have selected.
Control Panel This section explains proper mobile air conditioner
operation. Push buttons
Power button|
---|---
Timer button|
Sleep button|
Automatic, Cool, Dehumidify, Fan|
Speed button|
Mode button|
low. High fan speed|
Timer/ Temperature up button|
Timer/Temperature down button|
Control Panel Operation
⚫ Automatic, Cool, Dehumidify, Fan
-
Turn on the unit
a) Plug in, then the unit beeps once.
b) Press the button, then the unit is turned on.
The LED displays the room temperature.
Press the button again, the unit is turned off. -
Select operating mode
Press the button each time the mode will circle as below, when the mode indicator flash and no further
Press on the button, after several seconds, the operation mode is selected. -
Adjust Temperature
In cool mode only, the temperature can be set within a range of 15℃ to 31℃.
Press “+” or “– “button to increase or decrease the temperature 1℃ by pressing once.
The unit LED shows the target temperature for 5 seconds and then displays the room temperature -
Adjust Fan Speed
Press the “ “button to select a desired fan speed shown as below: -
Power
When you press “ “button again, the unit will beep and stop working.
Notice:
Each mode working principle mode
-
Once the operation is selected, the indoor temperature sensor detects room temperature.
automatically to select the desired operation mode with or -
When the room temperature ≥24℃, the unit will automatically select mode.
-
When the room temperature <24℃, the unit will automatically select mode.
Dehumidify mode
- The up centrifugal fan will run at low speed, and the speed can’t be adjusted.
- The unit adopts constant temperature dehumidifying mode, and the adjustment of temperature is no effective.
Cool mode
1.When the room temperature is higher than set temperature, the compressor starts to run.
2.When the room temperature is lower than set temperature, the compressor stops, and upper fan operates at original set speed.
Fan mode
-
The fan runs at set speed, and the compressor does not run.
-
The adjustment of temperature is no effective.
Time function -
Press “Timer’ button to set Automatically Off time while the unit is running, the timer icon (h) light is on.
-
Press “Timer” button to set Automatically On time while the unit is ready, the timer icon(h)light is on.
-
The time can be adjusted within a range of 1 hour to 24 hours. Press the temp up (+) or temp down (-) button to increase or decrease the time 1 hour by pressing once.
Sleep mode
1.The operation is effective when the unit is under mode.
2.Press the button in mode, then the unit will work under sleep mode and the up centrifugal fan will turn to low speed automatically (the speed icon light remains the previous setting). The set temperature will increase 1℃ after one hour and increase 2℃ after two hours. After six hours the unit will stop running.
Child lock operation
- Press and hold the button for 5seconds, the buttons will be locked.
Press and hold the button for 5seconds again, the buttons will be unlocked. Swing operation
When the swing button is activated, the swing blade swings left and right
automatically.
If you want to stop, press the button again.
Notice: Except the AUTO mode, the appliance has the memory function: when
the appliance is turned on it will return to the working mode before it turned
off in case the appliance has never been unplug form the main source.
Remote controller
The remote controller transmits signals to the system button turn on /off the
appliance
MODE
Select the mode
SPEED
Select the fan speed
and SETTING
Adjust the room temperature and the timer.
SLEEP MODE
Set or cancel Sleep mode operation.
TIMER
Set automatic off and automatic on time.
SWING
Used for automatic swing set.
How to install batteries
- Open the back cover, and take off the isolating film on the batteries.
- Put the batteries inside the slot, with anode and cathode in right directions;
- Put on the back cover.
Notices;
- The anode and cathode of the batteries must be corresponding to the signs of “+” and “-“ on the remote control;
- Do not use new battery cells together with run-down cells.
- For long time no use, take out the batteries
- To prevent environmental pollution, take out the used batteries and dispose safely and appropriately.
HOW TO USE
To operate the air conditioner, point the remote controller at the signal
receptor. The remote controller will operate the air conditioner at distance
of up to 5m when pointing at signal receptor of the air conditioner.
Protection
Operating condition
The protective device may operate and stop the appliance in the cases listed
below.
Cooling | Indoor air temperature is over 43°C |
---|
Room temperature is below 15°C
Features of protector
The protective device will work in the following cases.
- Restarting the unit at once after operation stops or changing mode during
drain eater
Special reminder: there is condensing water recycling hidden within this
unit. The condensing water is partly kept recycling between the condenser and
the water plate. When the water level rises to upper level, the float switch
and water full indicator (E4) lights on to remind draining water.
Please cut off the power supply, move the appliance to a suitable place,
remove the drain plug, and connect the hose (inner diameter 10mm, not
included) to drain water completely. After the drain, re-install the drain
plug, or the appliance may leak and make your room wet. If the appliance is
placed in a position admitting drain water, you also can connect the drain
hose to the drain port to drain water.
Maintenance
Appliance maintenance
Use lukewarm water (below 40°C(104°F ) to clean if the appliance is very
dirty.
Never use volatile substance such as gasoline or polishing powder to clean the
appliance.
Never sprinkle water onto the main unit
Air filter maintenance
It is necessary to clean the air filter after using it for about 100 hours.
Clean it as follows:
Stop the appliance and remove the air filter.
Clean and reinstall the air filter.
If the dirt is conspicuous, wash it with a solution of detergent in lukewarm
water.After cleaning, dry Ss it in a shaded and cool place, then reinstall
it. Clean the air filter every
two weeks if the air conditioner operates in an extremely dusty environment.
Maintanance after using
- If the appliance will not be used for a long time, be sure to Pull out the primary and the secondary rubber plug of the drain port, to drain the water. Re-install the rubber plug after drain.
- Keep the appliance running with fan only for a half day during a sunny day to dry the appliance inside and prevent from going moldy.
- Stop the appliance and pull out the power supply plug, then take out the batteries of remote controller and store appliance properly.
1. Clean the air filter and reinstall it.
2. 5. Remove the air hoses and store them properly, and cover the hole tightly.
Troubleshooting
The following cases may not always be a malfunction, please check suggestions
below before asking for service.
Does not run * If the protector trip or fuse is blown.
- Please wait for 3minutes and start again, protector device may be preventing unit from working.
- If batteries in the remote controller are exhausted.
If the plug is not properly plugged in
Runs for a short while only * If the set temperature is close to room temperature, you can lower the set temperature. - Air outlet is blocked by obstacle. Take the obstacle away.
Runs but not cooling If the door or window is open.
If there is another appliance heat-working like heater or lamp etc. - The air filter is dirty, please clean it.
- Air outlet or intake is blocked.
- Set temperature is too high.
Water leak during moving * Drain the condensate before moving. - To avoid water leakage, please locate the unit on flat ground. * Pull out the rubber plug to drain water.
- If it’s often in this state, please contact qualified service technical.
Before claiming repair, check the machine as follows:
Failures | Causes | Solutions |
---|---|---|
Machine fails to start up. | Power supply failure: |
I. Not plugged
2.Plug or socket damaged
3.Fuse broken| 1. Plug in
2.Replace the power cord or socket; Contact qualified technical service
3.Replace the furse by service provider (specification: 6.3A/250V AC)
Machine automatically stops| TIMING shut down or set temperature reached|
Restart or wait for auto-switch
No cold air under COOLING mode| I. Room temperature lower than set temperature
2. Machine enters into anti-frost protection| I. This is a normal phenomenon,
the machine will auto-switch while the room temperature is higher than the set
temperature
2. The machine will auto switch after anti-frost protection is over
LED displays failure code “E2”| Room temperature sensor fails or damaged|
Replace the room temperature sensor. Contact qualified technical service.
LED displays failure code “E3”| The evaporator oil pipe sensor fails or
damaged| Replace the evaporator coil pipe sensor. Contact qualified technical
service.
LED displays failure code “E4”| Water-full warning| Drain out the water
Installation
Installation accessories
- Air exhaust duct
- Connector of air exhaust duct
- Window exhaust adapter
- Remote control
- Baffle plate
Select the best location
- Beside a window, a door or a French window.
- Keep the required distance from the return air outlet to the wall or other obstacles at least 60cm (19 1/2”)
- Fix one end of the air hose on the air outlet underside the appliance Extend the air hose to ensure that other end of the air hose has clearance between the window,Door, or French window, or wall hole.
- Air outlet or intake cannot be blocked by protective grid or any obstacle.
Install Exhaust Hose and Adapter
How to connect the connectors to the Air exhaust duct.
- Extend the air exhaust duct (A) by drawing out the two ends of the duct.
- Screw the air exhaust duct into the connector of air exhaust duct
- Screw the connector of window into the plastic connectors.
- Connect the connector of air the unit. exhaust duct to
Using Information
Warranty Information
The manufacturer provides 1year warranty starting from the date on which the
appliance arrives at the destination port.
The repair under warranty may only be carried out by an authorized service
center. When making a claim under the warranty, the original bill of purchase
(with purchase date) must be Submitted.
The warranty will not apply in cases of:
- Normal wear and tear
- Incorrect use, e.g., overloading of the appliance, use of non-approved accessories
- Use of force, damage caused by external influences
- Damage caused by non-observance of the user manual, e.g., connection to an unsuitable mains supply or non-compliance with the installation instructions
- Partially or completely dismantled appliances
Cautions
- Keep the unit at least 1meter away from TV or radios to avoid electromagnetic interference.
- Do not expose the unit under direct sun light to avoid surface color fading.
- Do not tilt the unit for more than 35º or upside-down while transporting
- Place the unit on a flat surface with less than 5º inclination
- The unit operates more efficiently in certain room location (see technical specifications)
- Empty the condensed drainage pan before putting the unit in storage to prolong the unit lifetime at the end of the season.
- Do not use chemical solvents (e.g., Benzene, alcohol-glazer) to clean the unit surface to avoid scratching, damaging the surface.
- Make sure to cut off the power before disassembling or installing the air-inlet fence.
- Please empty the water from the water tank if you want to move the machine.
- The battery must be removed from the appliance before it is scrapped
- The battery is to be disposed of safely
- The plug must be removed before cleaning, maintaining, or filling the appliance.
Technical specification
Model | R-893 |
---|---|
Cooling Capacity (W) | 2600W |
Rated Voltage / Frequency (V/Hz) | 220-240V—/50Hz |
Net Weight (kg) | 20Kg |
Dimensions WXDXH | Body(mm) |
Package (mm) | 372x372x850mm |
Refrigerant | R290/120g |
IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH
EC DIRECTIVE 2002/96/EC.
At the end of its working life, the product must not be disposed of as urban
waste.
It must be taken to a special local authority differentiated waste collection
centre or to a dealer providing this service.
Disposing of a household appliance separately avoids possible negative
consequences for the environment and health, deriving form inappropriate
disposal and enables the constituent materials to be recovered to obtain
significant savings in energy and resources. As a reminder of the need to
dispose of household appliances separately, the product is marked with a
crossed-out wheeled dustbin.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>