PHILIPS WT120C G2 CoreLine Waterproof
INCLUDED
DIMENSION IN MM
Type | A | B | C | D | Emin | Emax | F | clips |
---|
WT120C G2 LED27S L1200
WT120C G2 LED40S L1200
| | 1215| | | 538| 1062| | 10
WT120C G2 LED34S L1500| 76| | 80| 38| | | 85|
WT120C G2 LED60S L1500| | 1515| | | 838| 1362| | 12
WT120C G2 LED80S L1500| | | | | | | |
INSTALLATION
PSU VERSION
Through wiring
INSTALL CABLE IN OTHER LOCATION (OPTIONAL)
REPLACEMENT OF SILICON PLUG (OPTIONAL)
Microwave Motion Sensor
- Mounting height: 4m max.
- Detecting angle: 150° (wall mounted)
The sensor is designed to connect one load only. Connecting more than one load may damage the sensor.
Hold time (default 5 min.) Refers to the time period the lamp remains at 100%illumination after no motion detected.
DIP Switch settings:
Detection area (default 100%) Detection area can be reduced by selecting the
combination on the DIP switches to fit precisely each application. Detection
radius: 6-8m (mounting height 3m)
Daylight sensor (default disabled)
The sensor can be set to only allow the luminaire to illuminate below a
defined ambient brightness threshold. When set to Disable mode, the daylight
sensor will switch on the luminaire when motion is detected regardless of
ambient light level. 40 lux, 30 lux: twilight operation, 10 lux, 2 lux:
darkness operation only.
| 1| 2| | | | 3| 4| 5| | | | 6| 7| 8| |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
I| ON| ON| 100%| | I| ON| ON| ON| 5 sec| | I| ON| ON| ON| 2 Lux|
II| | ON| 75%| | II| | ON| ON| 30 sec| | II| ON| ON| | 10 Lux|
III| ON| | 50%| | III| ON| | ON| 90 sec| | III| | ON| | 30 Lux|
IV| | | 25%| | IV| | | ON| 5 min| | IV| ON| | | 40 Lux|
| | | | | V| ON| ON| | 20 min| | V| | | | Disable|
10a| | | | | VI| | | | 30 min| | | | | | |
Radiation pattern
- Ceiling mounted height: 4m Sensitivity: 100%/75%/50%/25%
- Ceiling mounted height: 4m(*) Sensitivity:100%
- Horizon mounted height: 2.5m Sensitivity: 100%/75%/50%/25%
Only 100% detection sensitivity is workable when installed at 4m mounting height. 25%/50%/75% sensitivity is not able to detect motion signal.
Initialization:
After power on, the sensor automatically turns on light at 100% brightness.
After 10sec, it turns off the light. During the initialization, the sensor is
not able to detect movement.
Override function: quick switch ON/OFF 3 times within 2 sec to override sensor
function. Light will switch on regardless of motion. Power off and on again to
recover sensor function 10c
SERVICE
Light source (LED) is non-user replaceable. The light source contained in this luminaire shall only be replaced by the manufacturer or his agent or a similar qualified person. Do not touch electronic components! Electronic components maybe under high voltage.
Caution, risk of electric shock
DRIVER REPLACEMENT
OPEN LUMINAIRE
The batteries have a life time expectancy of 4 years. Do not touch electronic components! Electronic components may be under high voltage.
LED27S | LED34S | LED40S | LED60S | |
---|---|---|---|---|
Driver type | PSU | PSU | PSU | PSU |
lpeak [A] | 3,58 | 5,16 | 5,16 | 5,56 |
Tref [µs] | 40 | 47 | 47 | 47 |
Max. Nr of products
Drivers / MCB 16A type B [max.]| 80| 60| 60| 45
Drivers / MCB 10A type B [max.]| 50| 37| 37| 28
Drivers / MCB 16A type C [max.]| 136| 102| 102| 76
Drivers / MCB 10A type C [max.]| 80| 62| 62| 46
Light intensity distribution curves Emergency mode
- Do not stare into LED light beam.
- The luminaire shall be installed by a qualified electrician and wired in accordance with the latest IEE electrical regulations or the national requirements.
FUNCTIONAL NOTICE FOR EMERGENCY LIGHTING
Automatic emergency time selection
After installation and power up the driver will detect the battery and start the automatic detection process.
- During automatic detection, the indicator LED will light up with short green
- Between minimum 6 and maximum 30 seconds the Trust Sight driver will set the battery type (number of cells) and will set the emergency output power
After that, the system is defined and fully operational. The battery type definition has influence on the performance during the self-test and on the battery charge method. When the automatic battery detection process is disrupted, e.g. by switching off the permanent mains, the detection process is stopped and the Trust Sight emergency driver will go into emergency mode with the lowest output power. At a next power up, the automatic detection process will start again.
Periodic testing
Periodic tests of emergency lighting luminaires must be performed according to
EN50172 clause 7.2.3 and 7.2.4. Switch on in the emergency mode each month by
simulation of a failure of the supply to the normal lighting for a period
sufficient to ensure that each lamp is illuminated. Twice per year, each
luminaire shall be tested for its full rated duration (at least 3hrs).
For more information please consult the Trust Sight Gen 3 Design in guide. The
latest version is available online.
LED INDICATOR STATUS
Disconnect before servicing
Luminaire has basic insulation between Low Voltage supply and control conductors. The light source and/or control gear and/or the external flexible cable contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person. Storage, installation, use, operation and maintenance of the products needs to be performed exactly according the instructions in this manual and/or other instructions as may be provided by us to guarantee safe use of the product over its entire lifetime. Failure to adhere to these instructions will invalidate your entitlement to warranty. Bolts with indication of torque strength on the drawing need to be tightened using a calibrated torque wrench. Pre-assembled bolts need to be retightened again to the required torque specification to assure maximum strength over lifetime.
Zhaga-D4i and SR certified compatibility
For Zhaga-D4i/SR-Certified based luminaires only Zhaga-D4i/SR-Certified components/sensors are to be used (see also: https://www.zhagastandard.org/products / https://www.lighting.philips.co.uk /oem-emea/products/driving-connected-lighting). The functional compatibility of two SR-certified and/or Zhaga-D4i controllers/sensors to be used in combination, as well as the override possibility of any line-switch function used in an SR-based/Zhaga-D4i luminaire, is to be released by the master controller/sensor supplier. If using a NEMA 7-pin socket on an SR-based luminaire, a full system verification is required. Not following this advice can/will cause risk of damage and non-compliance for which Signify cannot take any responsibility.