Introduction
Congratulations on the purchase of your new device. With it, you have chosen a
high quality product.
During production, this equipment has been checked for quality and subjected
to a final inspection. The functionality of your equipment is therefore
guaranteed.
In some cases, residual amounts of water may therefore be present on or in the
device or in hose lines. This is not a fl aw or a defect and is no cause for
concern.
The operating instructions constitute part of this product. They contain
important information on safety, use and disposal.
Before using the product, familiarize yourself with all of the operating and
safety instructions. Use the product only as described and for the
applications specific ed. Keep this manual safely and in the event that the
product is passed on, hand over all documents to the third party.
Areas of Application
The rain barrel pump is designed for pumping water from a rain barrel or rain
collection tank. It is particularly suitable for garden irrigation. The device
is designed exclusively for the supply of clarifi ed water and rain water up
to a temperature of max. 35°C.
Any other use that is not expressly permitted in this instruction manual (e.g.
supply of food, salt water, motor fuels, chemical products or water with
abrasive substances) may result in damage to the device and pose a serious
hazard to the user. The device is not suitable for continuous operation.
Continuous operation will short en its service life and void the warranty.
This device is not suitable for commercial use. The warranty is void in the
case of commercial use.
The operator or user is responsible for any accidents or personal injury
and/or material damage to third parties or their property.
The manufacturer is not liable for damage caused by improper use or incorrect
operation.
General Description
An illustration of the most important functional components can be found on the fold-out pages.
Scope of Delivery
Carefully unpack the appliance and check that it is complete. Dispose of the packaging material correctly.
- Water Barrel Pump
- 2x Aluminium pipe
- Flexible pipe
- 5x Sealing ring
- Pipe holder
- Plastic hook with screw and wing nut
- Connector
- 3/4 & 5/8 Adapter
- Instructional manual
Overview
Pump
-
Float switch
-
Carrying handle
-
Pump housing
-
Suction foot
-
Cable
-
Fastening
Accessories -
Plastic hook
-
Wing nut
-
Screw
-
Connector
-
Adapter
-
Pipe holder
-
Small sealing ring
-
Medium-sized sealing ring
-
Large sealing ring
-
Shut-off valve
-
Flexible pipe
-
Screw sleeve
-
Lower/Upper aluminum pipe
-
Screw sleeves
A: 21 Pressure connection
B: 22 Filter cover
C: 23 Filter
Functional description
The pump is equipped with a fl oat switch that automatically switches the pump
on or off depending on the water level. In case of overload, the pump is
switched off by the built-in thermal protection switch. After cooling down,
the motor starts up again by itself.
A height-adjustable plastic hook on the aluminum pipe can be hooked into the
rain barrel and enables convenient water extraction via a water hose. The
shut-off valve has the function of a water tap
Technical Data
Water Barrel Pump ………………PRP 400 B1
Input voltage (U) ………….. 230 V~; 50 Hz
Power consumption (P) ………………400 W
Safety class …………………………………… I
Degree of protection …………………….IPX8Max. discharge rate
(Qmax) ……………………approx. 4000 l/h
Max. discharge head (Hmax) ………..13 m
Max. depth of immersion ……………….7 m
Max. foreign body size ………………. 3 mm
Max. water temperature (Tmax) ……..35°C
Mains cable ……………………………..10 m
Performance data
discharge rate Q (l/h)
Notes on Safety
Follow all safety instructions when using the machine.
Explanation of symbols Symbols on the device
Before beginning work, familiarise yourself thoroughly with all the operating
elements, particularly with how
they function and operate.
Ask a specialist if necessary.
Read and follow the operating instructions provided for the device
Do not use for pure sand water!
Max. immersion depth
Open and close the shut-off valve
Attention: Remove the plug from the socket as soon as the power lead is damage dor cut.
Electric appliances should not be disposed of in the domestic garbage.
Symbols in the manual
Warning symbols with information on damage and injury prevention
Hazard symbol with information on the prevention of personal injury caused by electric shock
Instruction symbols with information on preventing damage
Remove the mains plug!
Help symbols with information on improving tool handling
General notes on safety
Working with the equipment:
Caution: to avoid accidents and injuries:
-
This device is not intended for use by children, individuals with limited physical, sensory or mental capabilities, those with insofar client experience or knowledge or individuals who are not familiar with the instructions.
Children should be supervised to ensure that they do not play with the device.
Cleaning and maintenance must not be carried out by children. -
The machine must not be used at altitudes over 2000 m.
-
Never let children or persons who are not familiar with these instructions use the machine. Local regulations may restrict the age of the operator.
-
This device can be used by children aged 8 years and up as well as individuals with reduced physical, sensory or mental abilities or a lack of experience and knowledge if they are supervised or have been instructed in the safe use of the device and understand the resulting hazards. Children must never play with the device. Cleaning and user maintenance must not be carried out by children if the are not supervised.
-
Wear sturdy footwear to protect against electric shock.
-
Should there be people in the water, do not operate the equipment. Risk of electric shock!
-
Take appropriate measures to keep children away from the equipment whilst it is running. There is a risk of injury!
-
Do not use the equipment in the vicinity of fl ammable liquids or gases. Non-observance will result in a risk of fi re or explosion.
-
The transfer of aggressive, abrasive (grinding effect), corrosive, combustible (e.g. motor fuels) or explosive liquids, salt water, cleaning agents and foodstuffs is not permitted. The temperature of the liquid being transported must not exceed 35 °C.
-
Store the equipment in a dry place and out of reach of children.
Caution! To avoid damage to the equipment and any possible person injury resulting from this : -
Do not work with damaged or incomplete equipment, or with equipment that has been converted without the approval of the manufacturer. Before initial operation, have a specialist check that the required electrical protection measures are in place.
-
Monitor the equipment during operation (particularly in residential spaces, in order to detect automatic switching off or dry running of the pumps in time. Regularly check the function of the fl oat switch (see chapter “Operational start-up“). Non-observance will invalidate all guarantee and liability claims.
-
The pump is not suitable for continuous operation (e.g. for water features in garden ponds). Check the equipment regularly for correct functioning.
-
Note that the lubricants used in the equipment may cause dam-age or contamination if they escape. Do not use the pump in garden ponds with fi sh stocks or valuable plants.
-
Do not carry or fi x the equipment by the cable or pressure line.
-
Protect the equipment from frost and from running dry.
-
Use only original accessories and do not carry out conversion work on the equipment.
-
Please read the notes in the operating instructions on the topic of “Maintenance and Cleaning” and “Storage”. Any measures above and beyond these, particularly opening the equipment, are to be carried out by an electrician. In the case of repairs, always contact our service centre.
Electrical safety:
Caution: to avoid accidents and injuries from electric shocks:
- If there are people in the water, the device must not be operated. Risk of electric shock!
- After installation, the mains plug must be freely accessible when the equipment is in operation.
- Before operating your new pump, have a specialist check:
- The earthing, the protective multiple earthing; the residual current circuit breaking must be compliant with the safety regulations of the energy supply company and function without fault,
- The protection of the electri-cal plug connections from the wet.
- If there is a risk of flooding, fi x the plug connections in an area that is safe from flooding. Risk of electric shock.
- Ensure that the mains voltage matches the specifi cations on the rating plate.
- The electrical installation shall be according to national wiring rules.
- Connect the appliance only toa power socket with a residual current circuit breaker of rated residual current no more than 30 mA; fuse min. 6 ampere.
- Check the device, power connection cable and plug for damage before each use. Defective mains connection cables must not be repaired. They must be replaced wit new ones. Ensure that damage to your device is repaired by an authorised specialist.
- Do not use the mains connection cable to pull the plug out of the socket. Protect the mains connection cable from heat, oil and sharp edges.
- Use only extension cables that are splash-proof and designed for outdoor use. Always roll out the cable drum completely before use. Check the extension cable for damage.
- Remove the plug from the mains socket before carrying out work on the device, if there is a leak in the water system, during work breaks and when not in use.
- Mains connection cables must not have a cross-section that is smaller than those of rubber hoses with the designation H07RN8-F. The cable length must total 10 m. The wire cross section of the extension cable must be at least 2.5 mm2 .
- Protect mains cables and electrical connections from moisture. Make sure that mains connection cables and electrical connections are located in a fl oodproof area.
- If the cord of this device is damaged, it must be replaced by the manufacturer or their customer service or by a similarly qualifi ed person in order to avoid hazards.
Operational start-up
Assembly
Fitting the lower aluminium pipe
- Insert the large sealing ring (15) into the adapter (11) of the pressure connection.
- Screw the adapter (11) to the pressure connection (21) of the pump.
- Clip the pipe holder (12) with the middle holder to the aluminium pipe. The mounting rail of the pipe holder (12) must point downwards.
- Insert one of the two medium-sized sealing rings (14) into the screw sleeve (20).
- Place an aluminium pipe (19) onto the adapter (11) and screw it with the screw sleeve (20).
- Push the pipe holder (12) onto the aluminium pipe downwards until it engages in the recess on the device.
Fitting the upper aluminium pipe
- Connect the lower and upper aluminum pipe (19) using the connector (10). Place one of the small sealing rings (13) between the connector (10) and each of the two screw sleeves (18)
Fitting the plastic hook
- Loosen the wing nut (8) on the plastic hook (7).
- Remove the screw (9) from the plastic handle.
- Clip the plastic hook (7) onto the upper aluminium pipe (19).
- Fix the plastic hook (7) with the screw (9) and wing nut (8).
Fitting the fl exible pipe
- Insert the medium-sized sealing ring (14) into the screw sleeve (20).
- Push the fl exible pipe (17) onto the upper aluminium pipe (19) and screw it with the screw sleeve (20)
Immersing the pump
Be careful not to hold or hang the unit by the mains connection cable. There is a risk of electric shock due to damaged mains connection cables.
When immersing the pump, make sure that the shut-off valve(16) is open to ensure that the pump is vented.
- Use the plastic hook (7) or attach a rope to the pump‘s carrying handle (2) to immerse or raise the pump. Never hang the unit directly from the bent pipe or water hose
- You can adjust the height of the plastic hook after loosening the wing nut (8). This way you can hang the pump in a rain barrel without it touching the ground and sucking in possible sediment.
- When the water level is low, you can also place the pump in the rain barrel. The shut-off valve must protrude overthe edge of the container.
Beware of dirt and sand accumulating at the bottom of the barrel over time, which could damage the pump. We recommend placing the pump on a brick.
Mains connection
The pump you have purchased is already equipped with a safety plug. The pump is intended for connection to an earthed socket with residual current circuit breaker (RCCB) with 230 V ~ 50 Hz.
Operation
The minimum water level on initial start-up must be 60 mm
Adjusting the fl oat switch
Automatic operation
The on or off switching point of the fl oat switch (1) can be adjusted continuously.
- Disconnect the cable (5) of the fl oat switch (1) from the fastening, if necessary (6).
- Press the cable (5) in the desired position into the fastening (6).
Check the fl oat switch (1). It must be positioned so that it can rise and fall freely. The switching point height „On“ and the switching point height „Off“ must be easily reached.
**** There is a risk of dry running if the cable (5) of the fl oat switch is chosen too long, especially if the cable (5) is not hooked into the fastening (6) .
Manual operation
The pump runs continuously in manual operation. Position the fl oat switch (1), as shown, directly vertically in the fastening (6).
Switching on and off
- Open the shut-off valve (16). → Turn in + direction Use the shut-off valve to regulate the amount of water that fl ows into the connected water hose.
- Fully immerse the pump.
- Insert the mains plug in the socket. The pump starts immediately.
- To switch off, pull the plug out of the socket. The pump switches off.
If the water level is too low, the fl oat switch will automatically switch off the pump.
Supervise the appliance while it is in operation in order to be immediately aware if the automatic cut-out operates or the pump runs dry, to limit any damage to a minimum.
Maintenance/ Cleaning/ Storage
Clean and maintain your equipment regularly. This will guarantee its performance and long durability
Ask our service centre to carry out any work that is not described in these instructions. Use only original parts. There is a risk of injury!
Pull out the power plug before every maintenance operation. There is a risk of electrocution or of injury from moving parts.
General cleaning instructions
- Clean the pump with clean water after each use.
- Remove any fl uff and fi brous particles that may have become trapped on and under the pump housing (3) with a water jet.
- Clean the fl oat switch (1) and the suction foot (4) of deposits with clear water.
Cleaning the fi lter
The pump has a removable fi lter in the suction foot that protects it from contamination. Depending on the degree of contamination of the water, it should be checked occasionally and cleaned if necessary:
- Unplug the mains plug.
- Turn the fi lter cover (22) a ¼ turn clockwise.
- Remove the fi lter cover (22).
- Clean the fi lter (23) under running water.
- Install the fi lter (23) and fi lter cover (22) in reverse order.
The pump must not be operated with the fi lter (23).
Flushing the pump
After pumping heavily polluted water, the pump must be fl ushed to prevent deposits in the pump.
- Pump lukewarm water (max. 35 °C) until the pumped water is clear.
Storage
- Clean the pump before storage.
- Store the appliance in a dry, frost-free place, and where children cannot gain access to it.
- When the pump is not to be used for a longer period, it must be thoroughly cleaned after its last use, and before it is next used. Otherwise there may be problems in starting the pump, caused by deposits and residues.
Space-saving storage
- Dismantle the fl exible pipe (17) and the upper aluminium pipe (19).
- Clip the fl exible pipe (17) and the upper aluminium pipe (19) right and leftinto the pipe holder (12).
Keep the sealing rings (13/14) in a safe place.
All other measures, particularly opening the pump must be carried out by a qualifi ed electrician. Always contact the Service Centre if repairs are needed.
Waste Disposal and Environmental Protection
Be environmentally friendly. Return the tool, accessories and packaging to a recycling centre when you have fi nished with them.
Electric appliances should not be disposed of in the domestic garbage.
- Hand the tool in at a recycling centre. The plastics and metal parts can be separated and recycled. Ask your Service Center about this.
- Defective units returned to us will be disposed of for free.
Replacement parts/ Accessories
Spare parts and accessories can be obtained at
www.grizzlytools.shop
If you have issues ordering, please use the contact form. If you have any other questions, contactthe ”Service-Center” (see page 29).
7 | Plastic hook | 91105969 |
---|---|---|
10 | Connector | |
11 | Adapter | |
13-15 | 5x Sealing ring | |
17 | Flexible pipe | |
19 | 2x Aluminium pipe |
Troubleshooting
Faults | Causes | Remedies |
---|---|---|
**** Pump does not start | **** Mains voltage is not applied | Check plug |
socket, cable, line and plug, where appropriate, have re- paired through
electrical specialist
Float switch (1) does not switch| Check the position of the float switch
**** Pumps has no discharge| Water level too low during com-
missioning| Immerse pump deeper
Thermal protection switch has switched off| Wait until the motor
switches on again after cooling downPull out the mains plug and clean the
suction foot/impeller
Filter cover ( 22) / Filter ( 23) blocked| Clean the
filter cover/filter
Pump oper- ating but not pumping| Pressure line closed| Open the shut-
off valve (16) on the dis- tributor or other taps, nozzles, etc.
**** Flow rateinsufficient| Pump performance reduced due to
heavy dirt contamination or abrasive water impurities| Pull out the mains plug
and clean the pump, replace consumable parts if necessary (see “Cleaning,
mainte- nance and storage”)
Float switch (1) cannot sink| Check the position of the float switch
Filter cover ( 22) / Filter ( 23) blocked| Clean the filter
cover/filter
Pumping capacity reduced due to very dirty and abrasive ad- mixtures of
water| Pull out the mains plug and clean the pump, replace consumable parts if
necessary (see “Cleaning, mainte- nance and storage”)
Pump switch- es off after a short period| Motor contactor disconnects
the pumps because of water pollu- tion that is too severe| **** Pull out the
mains plug and clean.
Water temperature too high, mo- tor contactor breaks| Note maximum water
temperature of35°C!
Guarantee
Dear Customer,
This equipment is provided with a 3-year guarantee from the date of purchase.
In case of defects, you have statutory rights against the seller of the
product. These statutory rights are not restricted by our guarantee presented
below.
Terms of Guarantee
The term of the guarantee begins on thedate of purchase. Please retain the original receipt. This document is required as proof of purchase. If a material or manufacturing defect occurs within three years of the date of purchase of this product, we will repair or replace – at our choice – the product for you free of charge. This guarantee requires the defective equipment and proof of purchase to be presented within the three-year period with a brief written description of what constitutes the defect and when it occurred. If the defect is covered by our guarantee, you will receive either the repaired product or a new product. No new guarantee period begins on repair or replacement of the product.
Guarantee Period and Statutory Claims for Defects
The guarantee period is not extended by the guarantee service. This also applies for replaced or repaired parts. Any damages and defects already present at the time of purchase must be reported immediately after unpacking. Repairs arising after expiry of the guarantee period are chargeable.
Guarantee Cover
The equipment has been carefully produced in accordance with strict quality
guidelines and conscientiously checked prior to delivery.
The guarantee applies for all material and manufacturing defects. This
guarantee does not extend to cover product parts that are subject to normal
wear and may therefore be considered as wearing parts (e.g. backfl ow stop,
sealing ring) or to cover damage to breakable parts (e.g. switches). This
guarantee shall be invalid if the product has been damaged, used incorrectly
or not maintained. Precise adherence to all of the instructions specifi ed in
the operating manual is required for proper use of the product. Intended uses
and actions against which the operating manual advises or warns must be
categorically avoided. The product is designed only for private and not
commercial use. The guarantee will be invalidated in case of misuse or
improper handling, use of force, or interventions not undertaken by our
authorised service branch. In particular, there is no warranty claimwhen
pumping abrasive materials (sand, stones) or aggressive liquids, as this may
damage seals, impeller, motor or other parts.
Caution: The rain barrel pump is not suitable as a continuous running
pump (e.g. for streams or pond fountains). The warranty claim will expire in
case of misuse. The warranty claim will also become void if the rain barrel
pump is used without a baseplate or in the event of damage caused by holding
or hanging on to the mains connection cable. The rain barrel pump must not run
dry or be exposed to frost.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>