Please Read and Save These Instructions.
GX5A Pro Series Fan Mitigation fan For Extra Suction
DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL SERVICE TO FAN IS LOCKED IN “OFF” POSITION. DISCONNECT POWER BEFORE SERVICING FAN.
-
WARNING! For General Ventilating Use Only. Do Not Use to Exhaust Hazardous, Corrosive or Explosive Materials, Gases or Vapors. See Vapor Intrusion Application Note #AN001 for important information on VI Applications.
RadonAway.com/vapor-intrusion -
NOTE: Fan is suitable for use with solid state speed controls; however, use of speed controls is not generally recommended.
-
WARNING! Check voltage at the fan to insure it corresponds with nameplate.
-
WARNING! Normal operation of this device may affect the combustion airflow needed for safe operation of fuel burning equipment. Check for possible backdraft conditions on all combustion devices after installation.
-
NOTICE! There are no user serviceable parts located inside the fan unit. Do NOT attempt to open. Return unit to the factory. (See Warranty, p. 7, for details.)
-
WARNING! Do not leave fan unit installed on system piping without electrical power for more than 48 hours. Fan failure could result from this non-operational storage.
-
WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. (See p. 7.)
b) Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
c) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire rated construction.
d) Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturers’ guidelines and safety standards such as those published by any National Fire Protection Association, and the American Society for Heating, Refrigerating and Air Conditioning Engineers (ASHRAE), and the local code authorities.
e) When cutting or drilling into a wall or ceiling, do not damage electrical wiring and other hidden utilities.
f) Ducted fans must always be vented to outdoors.
g) If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit.
SYSTEM DESIGN CONSIDERATIONS
1.1 INTRODUCTION
The GX5A Pro Series Radon Fan is intended for use by trained, professional,
certified/licensed radon mitigators. The purpose of these instructions is to
provide additional guidance for the most effective use of GX Pro Series Fans.
These instructions should be considered supplemental to EPA/radon industry
standard practices, state and local building codes and regulations. In the
event of a conflict, those codes, practices and regulations take precedence
over these instructions.
1.2 FAN SEALING
The GX5A Pro Series Fan is factory sealed; no additional caulk or other
materials are required to inhibit air leakage.
1.3 ENVIRONMENTALS
The GX5A Pro Series Fan is designed to perform year-round in all but the
harshest climates without additional concern for temperature or weather. For
installations in an area of severe cold weather, please contact Radon Away for
assistance. When not in operation, the fan should be stored in an area where
the temperature is never less than 32 degrees F or more than 100 degrees F.
1.4 ACOUSTICS
The GX5A Pro Series Fan, when installed properly, operate with little or no
noticeable noise to the building occupants. The velocity of the outgoing air
should be considered in the overall system design. In some cases the “rushing”
sound of the outlet air may be disturbing. In these instances, the use of a
Radon Away Exhaust Muffler is recommended. (To ensure quiet operation of
inline and remote fans, each fan shall be installed using sound attenuation
techniques appropriate for the installation. For bathroom and general
ventilation applications, at least 8 feet of insulated flexible duct shall be
installed between the exhaust or supply grille(s) and the fan(s). The GX5A Pro
Series Fan is not suitable for kitchen range hood remote ventilation
applications.)
1.5 GROUND WATER
In the event that a temporary high water table results in water at or above
slab level, water may be drawn into the riser pipes, thus blocking air flow to
the GX5A Pro Series Fan. The lack of cooling air may result in the fan cycling
on and off as the internal temperature rises above the thermal cutoff. Should
this condition arise, it is recommended that the fan be turned off until the
water recedes, allowing for return to normal operation.
1.6 SLAB COVERAGE
The GX5A Pro Series Fan can provide coverage up to 2000+ sq. ft. per slab
penetration. This will primarily depend on the sub-slab material in any
particular installation. In general, the tighter the material, the smaller the
area covered per penetration. Appropriate selection of the Radon Fan best
suited for the sub-slab material can improve the slab coverage. The GX5A Fan
is best suited for tighter soils where higher suction is needed. Consider
using the RP260 where additional airflow is required, and the RP265 and RP380
for large slab, high airflow applications. Additional suction points can be
added as required. It is recommended that a small pit (5 to 10 gallons in
size) be created below the slab at each suction hole.
1.7 CONDENSATION & DRAINAGE
Condensation is formed in the piping of a mitigation system when the air in
the piping is chilled below its dew point. This can occur at points where the
system piping goes through unheated space such as an attic, garage or outside.
The system design must provide a means for water to drain back to a slab hole
to remove the condensation. The GX5A Pro Series Fan MUST be mounted vertically
plumb and level, with the outlet pointing up for proper drainage through the
fan. Avoid mounting the fan in any orientation that will allow water to
accumulate inside the fan housing. The GX5A Pro Series Fan is NOT suitable for
underground burial.
For GX5A Pro Series Fan piping, the following table provides the minimum
recommended pipe diameter and pitch under several system conditions.
Pipe Diameter | Minimum Rise per Ft of Run* |
---|---|
@25 CFM | @50 CFM |
4″ | 1/8″ |
3″ | 1/4″ |
See p. 6 for detailed specifications.
1.8 SYSTEM MONITOR & LABEL
A System Monitor is required to notify the occupants of a fan system
malfunction. The GX5A Fan requires a U-tube Manometer >5.5” max. (such as P/N
50036). You may choose to also use an audible alarm (P/N 28001-2, 280014,
28421 or 28535). A System Label (provided with Manometers P/N 50036) with
instructions for contacting the installing contractor for service and
identifying the necessity for regular radon tests to be conducted by the
building occupants must be conspicuously placed in a location where the
occupants frequent and can see the label.
1.9 ELECTRICAL WIRING
The GX5A Pro Series Fan operates on standard 120V, 60Hz AC. All wiring must be
performed in accordance with National Fire Protection (NFPA) National
Electrical Code, Standard #70, current edition, for all commercial and
industrial work, and state and local building codes. All wiring must be
performed by a qualified and licensed electrician. Outdoor installations
require the use of a UL Listed watertight conduit. Ensure that all exterior
electrical boxes are outdoor rated and properly sealed to prevent water
penetration into the box. A means, such as a weep hole, is recommended to
drain the box.
INSTALLATION
The GX5A Pro Series Fan can be mounted indoors or outdoors. (It is suggested
that EPA and radon mitigation standards recommendations be followed in
choosing the fan location.) The GX5A Fan may be mounted directly on the system
piping or fastened to a supporting structure by means of an optional mounting
bracket.
The ducting from the fan to the outside of the building has a strong effect on
noise and fan energy use. Use the shortest, straightest duct routing possible
for best performance, and avoid installing the fan with smaller ducts than
recommended. Insulation around
the ducts can reduce energy loss and inhibit mold growth. Fans installed with
existing ducts may not achieve their rated airflow.
2.1 MOUNTING
Mount the GX5A Pro Series Fan vertically with outlet up. Ensure the unit is
plumb and level. When mounting directly on the system piping assure that the
fan does not contact any building surface to avoid vibration noise.
2.2 MOUNTING BRACKET (optional)
The GX5A Pro Series Fan may be optionally secured with the Radon Away P/N
25007 mounting bracket. Foam or rubber grommets may also be used between the
bracket and mounting surface for vibration isolation.
2.3 SYSTEM PIPING
Complete piping run, using flexible couplings as a means of disconnect for
servicing the unit and for vibration isolation. As the fan is typically
outside of the building thermal boundary and is venting to the outside,
installation of insulation around the fan is not required.
2.4 ELECTRICAL CONNECTION
Connect wiring with wire nuts provided, observing proper connections (See
Section 1.9). Note that the fan is not intended for connection to rigid metal
conduit.
2.5 VENT MUFFLER (optional)
Install the muffler assembly in the selected location in the outlet ducting.
Solvent weld all connections. The muffler is normally installed at the end of
the vent pipe.
2.6 OPERATION CHECKS & ANNUAL SYSTEM MAINTENANCE
__ Verify all connections are tight and leak-free.
__ Ensure the GX5A Pro Series Fan and all ducting are secure and
vibration-free.
__ Verify system vacuum pressure with manometer. Ensure vacuum pressure is
within normal operating range and less than the maximum recommended operating
pressure.
(Based on sea-level operation, at higher altitudes reduce by about 4% per 1000
feet)
(Further reduce Maximum Operating Pressure by 10% for High Temperature
environments.)
See Product Specifications. If this is exceeded, increase the number of
suction points.
__ Verify Radon levels by testing to EPA Protocol and applicable testing
standards.
THE FOLLOWING CHARTS SHOW THE PERFORMANCE OF THE GX5A PRO SERIES FAN
GX5A PRO SERIES FAN Product Specifications
Typical CFM Vs. Static Pressure “WC|
---|---
Model| 0″| 0.2″| 1.0″| 2.0″| 3.0″| 4.0″| 5.0″
GX5A| 178| 171| 152| 120| 80| 48| 8
Model| Power Consumption
120VAC, 60Hz, 1.5 Amp Maximum| Maximum Recommended Operation Pressure*
(Sea Level Operation)**
---|---|---
GX5A| 80-180 watts| 5.00″ WC
*Reduce by 10% for High Temperature Operation **Reduce by 4% per 1000 ft. of altitude.
Model | Size | Weight | Inlet/Outlet | L.2 |
---|---|---|---|---|
GX5A | 11.1″H x 11.9″ Dia. | 9 lbs | 4.5″OD (4.0″ PVC Sched 40 size compatible) |
25
L.2 = Estimated Equivalent Length of Rigid Metal Ducting resulting in .2” WC pressure loss for Duct Size listed. Longer Equivalent Lengths can be accommodated at Flows Lower than that at .2” WC pressure loss (see CFM Vs Static Pressure “WC Table).
GX5A Pro Series Fan Additional Specifications
Model| Recommended Duct| PVC Pipe Mounting| Thermal
Cutout| Insulation Class
---|---|---|---|---
GX5A| 3″ or 4″ Schedule
20/40 PVC| Mount on the duct pipe or with optional mounting bracket.
For Ventilation: 4″, 6″ or 8″ Rigid or Flexible Ducting.| 150°C/302°F| Class F
Insulation
Continuous Duty
3000 RPM
Thermally Protected
Residential and Commercial
Rated for Indoor or Outdoor Use
IMPORTANT INSTRUCTIONS TO INSTALLER
Inspect the Radon Away® GX5A Pro Series Fan for shipping damage within 15 days
of receipt. Notify Radon Away of any damages immediately. Radon Away is not
responsible for damages incurred during shipping. However, for your benefit,
Radon Away does insure shipments.
There are no user serviceable parts inside the fan. Do not attempt to open the
housing. Return unit to factory. (See Warranty below).
Install the GX Pro Series Fan in accordance with all EPA, ANSI/AARST standard
practices, and state and local building codes and regulations.
Provide a copy of this instruction or comparable radon system and testing
information to the building occupants after completing system installation.
Warranty
Radon Away® warrants that the GX5A Pro Series Fan (the “Fan”) will be free
from defects in materials and workmanship for a period of 12 months from the
date of purchase or 18 months from the date of manufacture, whichever is
sooner (the “Warranty Term”).
Radon Away® will replace any fan which fails due to defects in materials or
workmanship during the Warranty Term. This Warranty is contingent on
installation of the Fan in accordance with the instructions provided. This
Warranty does not apply where any repairs or alterations have been made or
attempted by others, or if the unit has been abused or misused. Warranty does
not cover damage in shipment unless the damage is due to the negligence of
Radon Away®.
The Fan must be returned (at Owner’s cost) to the Radon Away® factory. Any Fan
returned to the factory will be discarded unless the Owner provides specific
instructions along with the Fan when it is returned regardless of whether or
not the Fan is actually replaced under this warranty. Proof of purchase must
be supplied upon request for service under this Warranty.
5-YEAR EXTENDED WARRANTY WITH PROFESSIONAL INSTALLATION.
Radon Away® will extend the Warranty Term of the fan to 60 months (5 years)
from date of purchase or 66 months from date of manufacture, whichever is
sooner, provided that the fan is installed by a professional radon mitigation
contractor. Proof of purchase
and/or proof of professional installation may be required for service under
this warranty. No extended warranty is offered outside the Continental United
States and Canada beyond the standard 12 months from the date of purchase or18
months from the date of
manufacture, whichever is sooner.
Radon Away® is not responsible for installation, removal or delivery costs
associated with this Warranty.
LIMITATION OF WARRANTY
EXCEPT AS STATED ABOVE, THE GX5A PRO SERIES FAN IS PROVIDED WITHOUT WARRANTY
OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULARPURPOSE.
IN NO EVENT SHALL RADONAWAY BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL,
INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING OUT OF, OR RELATING TO, THE FAN
OR THE PERFORMANCE THEREOF. RADONAWAY’S AGGREGATE LIABILITY HEREUNDER SHALL
NOT IN ANY EVENT EXCEED THE AMOUNT OF THE PURCHASE PRICE OF SAID PRODUCT. THE
SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY SHALL BE THE REPAIR OR
REPLACEMENT OF THE PRODUCT, TO THE EXTENT THE SAME DOES NOT MEET WITH
RADONAWAY’S WARRANTY AS PROVIDED ABOVE.
For service under this Warranty, contact Radon Away for a Return Material
Authorization (RMA) number and shipping information. No returns can be
accepted without an RMA. If factory return is required, the customer assumes
all shipping costs, including insurance, to and from factory.
Radon Away®
3 Saber Way, Ward Hill, MA 01835 USA
TEL 978-521-3703 FAX
978-521-3964
Email to: Returns@RadonAway.com
Record the following information for your records:
Serial Number:
Purchase Date:
IN097 Rev C 0223
3 Saber Way, Ward Hill, MA 01835 | radonaway.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>