EC6 Radon and Vapor Intrusion Fan
Instruction Manual EC6 Radon & Vapor Intrusion Fan
Installation Instructions
EC6 Radon & Vapor Intrusion Fan
INSTALLATION & OPERATING INSTRUCTIONS
DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE
ELECTRICAL SERVICE TO FAN IS LOCKED IN “OFF” POSITION. DISCONNECT POWER BEFORE
SERVICING FAN.
- WARNING! For General Ventilating Use Only. Do Not Use to Exhaust Hazardous, Corrosive or Explosive Materials, Gases or Vapors. See Vapor Intrusion Application Note #AN001 for important information on VI Applications. See RadonAway.com/vapor-intrusion.
- NOTE: Fan is not suitable for use with solid state speed controls. Fan has integral speed control.
- WARNING! Check voltage at the fan to insure it corresponds with nameplate.
- WARNING! Normal operation of this device may affect the combustion airflow needed for safe operation of fuel burning equipment. Check for possible backdraft conditions on all combustion devices after installation.
- NOTICE! There are no user serviceable parts located inside the fan unit. Do NOT attempt to open. Return unit to the factory for service.
- WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
b) Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag to the service panel.
c) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire rated construction.
d) Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney)
of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturers’ guidelines and safety standards such as those published by any National Fire Protection Association, and the American Society for Heating, Refrigerating and Air Conditioning Engineers (ASHRAE), and the local code authorities.
e) When cutting or drilling into a wall or ceiling, do not damage electrical wiring and other hidden utilities.
f) Ducted fans must always be vented to outdoors.
g) If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit.
INTRODUCTION
The EC6 Radon & Vapor Intrusion Fan is intended for use by trained,
professional, certified/licensed radon mitigators. The purpose of these
instructions is to provide additional guidance for the most effective use of
an EC6 Radon & Vapor Intrusion Fan. These instructions should be considered
supplemental to EPA/radon industry standard practices, state and local
building codes and regulations.
In the event of a conflict, those codes, practices and regulations take
precedence over these instructions.
MOUNTING
Mount the EC6 Radon & Vapor Intrusion Fan vertically. Ensure the unit is plumb and level. When mounting directly on the system piping assure that the fan does not contact any building surface directly to avoid transitioning motor noise to the structure.
ELECTRICAL WIRING
The EC6 Radon & Vapor Intrusion Fan operate on standard 120V, 60Hz AC. All
wiring must be performed in accordance with National Fire Protection (NFPA)
National Electrical Code, Standard #70 (current edition) for all commercial
and industrial work, and state and local building codes. All wiring must be
performed by a qualified and licensed electrician. Outdoor installations
require the use of a UL Listed watertight conduit. Ensure that all exterior
electrical boxes are outdoor rated and properly sealed to prevent water
penetration into the box.
3.1 ELECTRICAL CONNECTION
Connect wiring with wire nuts provided, observing proper connections (See
Figure 1. Note that the fan is not intended for connection to rigid metal
conduit. Please note that small, capped white fan wire is not used!
3.2 SPEED CONTROLS
The EC6 Radon & Vapor Intrusion Fan is not rated for use with separate
electronic speed control. To increase fan speed turn the speed control knob of
the integrated speed control clockwise. To reduce fan speed turn the speed
control knob counterclockwise. A small screwdriver may also be used to turn
the speed control knob. See Figure 2. 3.3 OPERATION
The EC6 should be operated within the pressure and air flow parameters shown
on Figures 3, 4 and 5. IMPORTANT INSTRUCTIONS TO INSTALLER
Inspect the RadonAway® EC6 Radon & Vapor Intrusion Fan for shipping damage
within 15 days of receipt. Notify RadonAway of any damages immediately.
RadonAway is not responsible for damages incurred during shipping. However,
for your benefit, RadonAway does insure shipments.
There are no user serviceable parts inside the fan. Do not attempt to open the
housing. See Warranty for return/replacement service.
Install the EC6 Radon & Vapor Intrusion Fan in accordance with all EPA,
ANSI/AARST standard practices, and state and local building codes and
regulations.
Provide a copy of this instruction or comparable radon system and testing
information to the building occupants after completing system installation.
WARRANTY
RadonAway® warrants that the EC6 Radon & Vapor Intrusion Fan (the “Fan”) will
be free from defects in materials and workmanship for a period of 12 months
from the date of purchase or 18 months from the date of manufacture, whichever
is sooner (the “Warranty Term”). RadonAway® will replace any fan which fails
due to defects in materials or workmanship during the Warranty Term. This
Warranty is contingent on installation of the Fan in accordance with the
instructions provided. This Warranty does not apply where any repairs or
alterations have been made or attempted by others, or if the unit has been
abused or misused. Warranty does not cover damage in shipment unless the
damage is due to the negligence of RadonAway®.
The Fan must be returned (at Owner’s cost) to the RadonAway® factory. Any Fan
returned to the factory will be discarded unless the Owner provides specific
instructions along with the Fan when it is returned regardless of whether or
not the Fan is actually replaced under this warranty. Proof of purchase must
be supplied upon request for service under this Warranty.
5-YEAR EXTENDED WARRANTY WITH PROFESSIONAL INSTALLATION.
RadonAway® will extend the Warranty Term of the fan to 60 months (5 years)
from date of purchase or 66 months from date of manufacture, whichever is
sooner, provided that the fan is installed by a professional radon mitigation
contractor. Proof of purchase and/or proof of professional installation may be
required for service under this warranty. RadonAway® is not responsible for
installation, removal or delivery costs associated with this Warranty.
LIMITATION OF WARRANTY
EXCEPT AS STATED ABOVE, THE EC6 RADON & VAPOR INTRUSION FAN IS PROVIDED
WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, WITHOUT
LIMITATION, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE. IN NO EVENT SHALL RADONAWAY BE LIABLE FOR ANY DIRECT, INDIRECT,
SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING OUT OF, OR RELATING TO,
THE FAN OR THE PERFORMANCE THEREOF. RADONAWAY’S AGGREGATE LIABILITY HEREUNDER
SHALL NOT IN ANY EVENT EXCEED THE AMOUNT OF THE PURCHASE PRICE OF SAID
PRODUCT. THE SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY SHALL BE THE REPAIR
OR REPLACEMENT OF THE PRODUCT, TO THE EXTENT THE SAME DOES NOT MEET WITH
RADONAWAY’S
WARRANTY AS PROVIDED ABOVE.
For service under this Warranty, contact RadonAway for a Return Material
Authorization (RMA) number and shipping information. No returns can be
accepted without an RMA. If factory return is required, the customer assumes
all shipping costs, including insurance, to and from factory..
RadonAway® 3 Saber Way
Ward Hill, MA 01835 USA TEL
978-521-3703
FAX 978-521-3964
Email to: Returns@RadonAway.com
LISTED Electric Fan
Conforms to UL STD. 507
Certified to CAN/CSA STD.
C22.2 No. 113
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>