RadonAway EC6 Radon and Vapor Intrusion Fan Instruction Manual

June 9, 2024
RadonAway

EC6 Radon and Vapor Intrusion Fan
Instruction ManualRadonAway EC6 Radon and Vapor Intrusion
Fan EC6 Radon & Vapor Intrusion Fan
Installation Instructions

EC6 Radon & Vapor Intrusion Fan

INSTALLATION & OPERATING INSTRUCTIONS
DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL SERVICE TO FAN IS LOCKED IN “OFF” POSITION. DISCONNECT POWER BEFORE SERVICING FAN.

  1. WARNING! For General Ventilating Use Only. Do Not Use to Exhaust Hazardous, Corrosive or Explosive Materials, Gases or Vapors. See Vapor Intrusion Application Note #AN001 for important information on VI Applications. See RadonAway.com/vapor-intrusion.
  2. NOTE: Fan is not suitable for use with solid state speed controls. Fan has integral speed control.
  3. WARNING! Check voltage at the fan to insure it corresponds with nameplate.
  4. WARNING! Normal operation of this device may affect the combustion airflow needed for safe operation of fuel burning equipment. Check for possible backdraft conditions on all combustion devices after installation.
  5. NOTICE! There are no user serviceable parts located inside the fan unit. Do NOT attempt to open. Return unit to the factory for service.
  6. WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
    a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
    b) Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag to the service panel.
    c) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire rated construction.
    d) Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney)
    of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturers’ guidelines and safety standards such as those published by any National Fire Protection Association, and the American Society for Heating, Refrigerating and Air Conditioning Engineers (ASHRAE), and the local code authorities.
    e) When cutting or drilling into a wall or ceiling, do not damage electrical wiring and other hidden utilities.
    f) Ducted fans must always be vented to outdoors.
    g) If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit.

INTRODUCTION

The EC6 Radon & Vapor Intrusion Fan is intended for use by trained, professional, certified/licensed radon mitigators. The purpose of these instructions is to provide additional guidance for the most effective use of an EC6 Radon & Vapor Intrusion Fan. These instructions should be considered supplemental to EPA/radon industry standard practices, state and local building codes and regulations.
In the event of a conflict, those codes, practices and regulations take precedence over these instructions.

MOUNTING

Mount the EC6 Radon & Vapor Intrusion Fan vertically. Ensure the unit is plumb and level. When mounting directly on the system piping assure that the fan does not contact any building surface directly to avoid transitioning motor noise to the structure.

ELECTRICAL WIRING

The EC6 Radon & Vapor Intrusion Fan operate on standard 120V, 60Hz AC. All wiring must be performed in accordance with National Fire Protection (NFPA) National Electrical Code, Standard #70 (current edition) for all commercial and industrial work, and state and local building codes. All wiring must be performed by a qualified and licensed electrician. Outdoor installations require the use of a UL Listed watertight conduit. Ensure that all exterior electrical boxes are outdoor rated and properly sealed to prevent water penetration into the box.
3.1 ELECTRICAL CONNECTION
Connect wiring with wire nuts provided, observing proper connections (See Figure 1. Note that the fan is not intended for connection to rigid metal conduit. Please note that small, capped white fan wire is not used!
RadonAway EC6 Radon and Vapor Intrusion Fan - fig 1 3.2 SPEED CONTROLS
The EC6 Radon & Vapor Intrusion Fan is not rated for use with separate electronic speed control. To increase fan speed turn the speed control knob of the integrated speed control clockwise. To reduce fan speed turn the speed control knob counterclockwise. A small screwdriver may also be used to turn the speed control knob. See Figure 2.RadonAway EC6 Radon and Vapor Intrusion
Fan - fig 2 3.3 OPERATION
The EC6 should be operated within the pressure and air flow parameters shown on Figures 3, 4 and 5.    RadonAway EC6 Radon and Vapor Intrusion Fan - fig
3 RadonAway EC6 Radon and Vapor Intrusion Fan -
fig 4IMPORTANT INSTRUCTIONS TO INSTALLER
Inspect the RadonAway® EC6 Radon & Vapor Intrusion Fan for shipping damage within 15 days of receipt. Notify RadonAway of any damages immediately. RadonAway is not responsible for damages incurred during shipping. However, for your benefit, RadonAway does insure shipments.
There are no user serviceable parts inside the fan. Do not attempt to open the housing. See Warranty for return/replacement service.
Install the EC6 Radon & Vapor Intrusion Fan in accordance with all EPA, ANSI/AARST standard practices, and state and local building codes and regulations.
Provide a copy of this instruction or comparable radon system and testing information to the building occupants after completing system installation.

WARRANTY

RadonAway® warrants that the EC6 Radon & Vapor Intrusion Fan (the “Fan”) will be free from defects in materials and workmanship for a period of 12 months from the date of purchase or 18 months from the date of manufacture, whichever is sooner (the “Warranty Term”). RadonAway® will replace any fan which fails due to defects in materials or workmanship during the Warranty Term. This Warranty is contingent on installation of the Fan in accordance with the instructions provided. This Warranty does not apply where any repairs or alterations have been made or attempted by others, or if the unit has been abused or misused. Warranty does not cover damage in shipment unless the damage is due to the negligence of RadonAway®.
The Fan must be returned (at Owner’s cost) to the RadonAway® factory. Any Fan returned to the factory will be discarded unless the Owner provides specific instructions along with the Fan when it is returned regardless of whether or not the Fan is actually replaced under this warranty. Proof of purchase must be supplied upon request for service under this Warranty.
5-YEAR EXTENDED WARRANTY WITH PROFESSIONAL INSTALLATION.
RadonAway® will extend the Warranty Term of the fan to 60 months (5 years) from date of purchase or 66 months from date of manufacture, whichever is sooner, provided  that the fan is installed by a professional radon mitigation contractor. Proof of purchase and/or proof of professional installation may be required for service under this warranty. RadonAway® is not responsible for installation, removal or delivery costs associated with this Warranty.

LIMITATION OF WARRANTY

EXCEPT AS STATED ABOVE, THE EC6 RADON & VAPOR INTRUSION FAN IS PROVIDED WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL RADONAWAY BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING OUT OF, OR RELATING TO, THE FAN OR THE PERFORMANCE THEREOF. RADONAWAY’S AGGREGATE LIABILITY HEREUNDER SHALL NOT IN ANY EVENT EXCEED THE AMOUNT OF THE PURCHASE PRICE OF SAID PRODUCT. THE SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY SHALL BE THE REPAIR OR REPLACEMENT OF THE PRODUCT, TO THE EXTENT THE SAME DOES NOT MEET WITH RADONAWAY’S
WARRANTY AS PROVIDED ABOVE.
For service under this Warranty, contact RadonAway for a Return Material Authorization (RMA) number and shipping information. No returns can be accepted without an RMA. If factory return is required, the customer assumes all shipping costs, including insurance, to and from factory..

RadonAway® 3 Saber Way
Ward Hill, MA 01835 USA TEL 978-521-3703
FAX 978-521-3964
Email to: Returns@RadonAway.com
LISTED Electric Fan
Conforms to UL STD. 507
Certified to CAN/CSA STD.
C22.2 No. 113