Failure to adhere to these instructions may result in water ingress, luminaire failure and void the Halcyon 5 year warranty. Please read carefully.

DIMENSION

  • Front cover

  • Reflector

  • Cable gland

  • Tempered glass

  • Housing Power

  • cable

  • Colour Temperature: 2700k

  • Input Voltage: 24V DC Constant Voltage (wire in parallel)

  • Ingress Protection Rating: IP67

  • To prevent voltage drop over a circuit total luminaire wattage plus voltage drop over the length of a cable run and cable gauge must be taken into account.

  • Always try to use a Constant Voltage Driver which is double the total circuit wattage.

  • Multistrand UV protected flex should be utilised for all exterior 24V DC CV circuits.

  • Luminaire front faces are all electropolished 316 grade Stainless Steel.

  • Applicable environment temperature: -20°C …. +40°C

  • All installation work must be carried out by a registered electrician.

OPTION A

Conduit Drainage
Install over a drained substrate and install conduit drains to effectively dissipate all water from base of housing (50mm+ conduit, see diagram). Conduit drains must be set with appropriate fall so water drains effectively. Drains should have exposed ends so water e.g. drain into nearby garden. After concrete has been poured ensure drains are free of debris, fill with water to test effectiveness of drainage.

DO NOT relv on iust the cable entry/exit conduit as a drainage point, this will only cause problems at the lowest lying luminaire.

OPTION B

  • Drained Substrate with Drain coil When install environment does not allow for conduit drainage system, install inground housing over a drained substrate (e.g. scoria) with drain coil underneath (see diagram below).
  • DO NOT install housing directly over compacted fine grade gravel or clay/dirt, this will result in poor drainage and the inground housing will flood with water.

HALCYON-EX330-USTSL2-18W-Exterior-Inground-Extra-Large-
FIG-4

INSTALL TIPS

There are two basic rules for a successful inground installation.

  1. Prevent water coming into the top of the housing with good seal between housing and base.
  2. Allow for water to effectively drain outwards from base of the housing with pre-prepared drainage.
    If you fail to address one or both of these points, you will have water pooling in the base of the housing and the luminaire/cable joins may be constantly submersed. Inground luminaires are rated to IP67 so are only protected for short periods of immersion in water, constant immersion will cause water ingress and luminaire failure.

Take extra care when setting heights of install housing, top lip of housing should sit perfectly flush with finished concrete level.
This way, when luminaire is installed the underside of the front trim will seal effectively against the housing and prevent excess water entering the housing. If the housing sits slightly under concrete finished level, when inground is installed the rim will not seal against the housing and water will ingress through the gap between underside of rim and inground housing. A poor seal will generally allow a greater volume of water than the drainage under the housing can dissipate, resulting in constant submersion and failure. Ensure clear communication with concrete layers / site manager to avoid them compromising your set up work during concrete pour.

HALCYON-EX330-USTSL2-18W-Exterior-Inground-Extra-Large-
FIG-5

CABLE JOINS
Always use IP68 resin joins or IP67 connectors. For joins which are not IP68/67 or have exposed junctions moisture may enter the luminaire tracking up the cable as the fitting heats and cools. DO NOT use heat shrink to seal an in-line 3-way join. Water will ingress the join in-between the two parallel cables.

HALCYON-EX330-USTSL2-18W-Exterior-Inground-Extra-Large-
FIG-6

Example of wiring:

HALCYON-EX330-USTSL2-18W-Exterior-Inground-Extra-Large-
FIG-7

24VDC: circuit of product

HALCYON-EX330-USTSL2-18W-Exterior-Inground-Extra-Large-
FIG-8

Material specifications

  • Housing: 12# die-casting grey powder coated aluminium,
    T=60-80um. adhesion of ISO class 1/ASTM class 4B

  • Front cover: Stainless steel 316L#

  • Glass: Tempered glass. (T=8mm)

  • Reflector: Optional lens, efficiency>=90%

  • Power cable: H05RN-F2x1.0mm? L=0.6M(low voltage/single color)

  • Mounting sleeve: B12

  • Cable gland: IP68 PG-9 PVC

  • Glass pressure capacity: Full area = 2578kgs

  • Driver: Constant current output

  • LED: Multi chip on board LED

Electrical parameters

Item No.

|

Light source

|

Reflector

|

Degree(0

)

|

Input voltage(V)

|

Typical

operating current(mA)

|

Typical comsumption(w)

|

Typical luminance(lm)

|

IK rate

---|---|---|---|---|---|---|---|---

EX330-USTSL2

| lx6W

COB LED

|

RS

|

40

|

24VDC

|

270

|

6.5

| Cool white=626 Warm white=458|

09