DNP XF6 Series Fire Control Panels
Product Information
- Product Name: XF6 Series Fire Control Panels
- Product Type: Addressable fire alarm control panel (FACP)
- Reliability: Proven reliability suitable for commercial and industrial installations
- Zone Expansion: Full range of zone expansion capability
- Communication: Eight communication paths between the panel and monitoring center
- Flash Updatable: Locally over cell or network
- Communication Options: Network communicator or optional cellular communicator
Product Usage Instructions
To use the XF6 Series Fire Control Panels, follow these steps:
- Mount the panel in a suitable location.
- Connect the necessary power supply. The panel comes with a factory-installed 24 VAC at 5.4 amp wire-in transformer.
- If using network monitoring, connect the panel to an Ethernet network using the built-in 10/100 auto-sensing Ethernet connection.
- If using cellular communication, install the optional 263 Series Cellular Communicators. These communicators can be used as the primary path for commercial fire installations.
- Configure the communication paths between the panel and monitoring center. You can set up to eight communication paths, each with its own programming parameters and identification as primary or backup.
- Check the communication function diagnostics from the annunciator to ensure network and cellular communication status and cell signal strength.
- Use the built-in fire graphic touchscreen annunciator to monitor system events and access menu prompts for easy operation.
Note: For further customization and firmware upgrades, refer to the user manual for instructions on remote or on-site firmware upgrade capability.
- Powerful addressable fire alarm control panel (FACP)
- Proven reliability suitable for commercial and industrial installations
- Full range of zone expansion, communication and relay output capability
- Flash updatable — locally over cell or network
- Network communicator or optional cellular communicator
FEATURES
- Six onboard 24 volt class B zones
- Eight communication paths between the panel & monitoring center
- Up to .5 amps 24 VDC smoke auxiliary output with OVC protection (switchable)
- Up to .5 amps 24 VDC smoke auxiliary output with OVC protection (non-switchable)
- Compatible with DMP zone expanders and other existing fire notification devices
- Built-on fire graphic touchscreen annunciator
- Two 2.5 amp NAC circuits
- Built-in remote or on-site firmware upgrade capability
- 12,000 event buffer
- French, Spanish and English menus available
- 12V aux output for compatibility with current zone expanders
Onboard Network
- Onboard 10/100 autosensing Ethernet
- Customizable check-in time and retry time
Models
- XF6-100 (6 onboard zones plus 1-LX Bus for 100 zone expansion)
- XF6-500 (6 onboard zones plus 5-LX Bus for 500 zone expansion)
FIRE CONTROL PANELS
XF6 FIRE PANELS
The XF6 provides fire monitoring for any single site application. The panel is
enhanced by the onboard Ethernet connection that allows the use of network
monitoring. The panel comes fully assembled from the factory with the
following components.
TOUCHSCREEN ANNUNCIATOR
The Fire Command Center mounted in the door displays system events and menu
prompts, making it efficient and easy to use.
TRANSFORMER AND ENCLOSURE
The 24 VAC at 5.4 amp wire-in transformer is factory installed.
FLEXIBLE COMMUNICATION
The commercial fire panels have transitioned from dialer-focused
communications to a true network and cellular communications approach,
providing stronger, multi-layered panel communications that ensure a constant
link between the panel and monitoring center.
NETWORK OR CELLULAR COMMUNICATION
Built-in 10/100 auto-sensing Ethernet connection enhances both standard and
encrypted line security options. Both UDP and TCP are supported. The panels
may be used with the 263 Series Cellular Communicators as the primary path (no
backup required) for commercial fire installations. The check-in and fail time
settings are programmed for five minutes. As the backup path, the 263
communicator provides the security of a communication link that continues to
function, even when landlines are cut or compromised. The communicators can be
used as a stand-alone communicator without the need for a backup. This
interface works over a variety of carriers in the USA and Canada.
EIGHT COMMUNICATION PATHS
Configure up to eight communication paths between the panel and monitoring
center. Each path has its own panel communication programming parameters and
can be identified as either primary or backup. This enables installers to
configure a reliable communication link, offering greater confidence that the
panel will always be connected to the monitoring center.
COMMUNICATION FUNCTION DIAGNOSTICS
The enhanced diagnostic menu enables technicians to check network and cellular
communication status and cell signal strength from the annunciator.
FIRE ZONE PROGRAMMING
Program zones for fire, fire verify, fire retard, presignal, cross zoning or
fire supervisory. This flexibility allows the ability to match individual zone
characteristics to the needs of any area in the fire installation.
ZONE EXPANSION
The system provides Class B powered zones. Up to 100 12V zones are available
on each built-in LX-Bus™ using expansion modules.
FIRE DRILL AND WALK TEST
Users can test fire notification bells using the Fire Drill feature. A special
code is also available for installers to test the system. The Walk Test allows
a single technician to check the panel response to fire, CO and supervisory
zones.
FLASH UPDATABLE
The XF6 Series panels accept software updates using Dealer Admin™. This makes
it easy to perform the flash update remotely any time new panel feature
updates release.
COMMERCIAL WIRELESS FIRE DEVICES
The list of DMP wireless devices that have earned the UL Commercial Fire
Listing include:
- 1103 Universal Transmitter: Offers the same look and features as the 1101 transmitter with the addition of a 470K end-of-line resistor, wall tamper switch and commercial fire listing.
- 1100R Wireless Repeater: Extends the communication range of DMP receivers, enabling physically larger, more reliable wireless security systems.
- 1100X Wireless Receiver: Supports up to 500 transmitters and satisfies all wireless applications.
- 1100XH High Power Wireless Receiver: Provides additional transmit and receive amplification for improved performance at greater distance or in harsh building environments.
- Commercial Smoke Detectors: The 1164 includes synchronized sounders and a tamper switch. The 1164NS is for applications with existing sounder/notification devices.
- 1183 Wireless Heat Detector: A reliable, ceiling-mount heat sensor available in two versions. The 1183-135F responds if the temperature exceeds 135°. The 1183-135R adds a rate-of-rise feature that responds if the temperature increases by 15°F per minute or more.
- 1184 Carbon Monoxide Detector: The ideal choice for difficult-to- wire locations, applications where room aesthetics are critical or where hazardous materials are present. The sensor provides an early alert of potentially harmful levels of carbon monoxide in residential or commercial installations. In addition, it also transmits trouble, tamper and low-battery messages to the panel.
COMPATIBILITY REFERENCE SHEET
Annunciators
- 630F LCD Remote Fire Command
- 7830F Graphic Touchscreen Annunciators
Expansion Modules
- 711 Single Zone Expansion
- 711S Zone Expansion Module
- 714 Four-Zone Class B Expansion
- 714-8 Eight-Zone Class B Expansion
- 714-16 16-Zone Class B Expansion
- 715 Four-Zone Two-Wire Smoke Expansion
- 715-8 Eight-Zone Two-Wire Smoke Expansion
- 715-16 16-Zone Two-Wire Smoke Expansion
- 716 Output Expansion, four Form C relays, four open collector outputs
Cellular Communicators
- 263LTE-V/381-2 LTE Communicator, Verizon
- 263LTE-A/381-2 LTE Communicator, AT&T
Auxiliary Modules
- 860 Relay Output Module
- 865 Style W/X Notification Circuit Module
- 866 Style W Notification Circuit Module
- 867 LX-Bus Notification Circuit Module
Smoke/Heat Detectors
- 2W-BLX Conventional Smoke
- 2WT-BLX Conventional Smoke/Heat
Monitoring Center Receivers
- SCS-1R Security Control Receiver
- SCS-VR (Virtual Receiver) Software-only solution that runs on a server for network IP and cellular communications
DMP Wireless
- 1100X Receiver
- 1100XH High Power Receiver
- 1100R Repeater
- 1103 Universal Transmitter, External Contact
- 1164 Smoke Detector with Synchronized Sounder
- 1164NS Smoke Detector with No Sounder
- 1166 Smoke Detector Ring
- 1168 Smoke/CO/Low Temp Detector
- 1183-135F Heat Detector (Fixed)
- 1183-135R Heat Detector (Rate of Rise)
- 1184 Carbon Monoxide Detector
Accessories
- 300 Four-Wire Harness
- 305 Plug-In Output Relay
- 431 Output Harness
Dealer Management
Dealer Admin
End User Management
Virtual Keypad
VirtualKeypad.com
800-641-4282 |
DMP.com
2500 N. Partnership Blvd, Springfield, MO 65803
Designed, engineered & manufactured in Springfield, MO using U.S. & global
components
LIMITED WARRANTY: DMP warrants that the products manufactured by DMP and
described herein shall be free from defects of manufacture, labeling, and
packaging for a period of three (3) years from the invoice date to the
original Buyer, provided that representative samples of the defective products
are returned to DMP for inspection…To read the full DMP Limited Warranty, go
to DMP.com/Warranty or check the DMP Price List or
Catalog.
© 2023 Digital Monitoring Products, Inc. | LT-5049
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>