Overview

This series are (PoE) Ethernet switches with 4 / 8 / 16 port Gigabit Ethernet

  • 2 port 1000Mbps SFP (PoE version available) with console port. The Ethernet switch uses the Layer 2 protocol, which is required in the industry to ensure the stability of the communication network. The switches in this series have low power consumption and a fanless design, so there is no noise. They support a wide operating temperature range of -40~80°C and offer good electromagnetic compatibility (EMC) to ensure stable operation in harsh industrial environments and quickly cater to industrial applications such as factory automation, intelligent transportation and video surveillance. A stable network terminal provides a secure and reliable solution.

Features

  • Data control: support 802.3X full-duplex flow control, support network storm suppression
  • Redundant network: support STP/RSTP/MSTP, support ERPS (self-healing time <20ms)
  • Multicast management: support IGMP Snooping V1/V2/V3
  • VLAN: Support IEEE 802.1Q VLAN, effectively isolate the broadcast domain
  • Link aggregation: support link static/dynamic aggregation, providing perfect bandwidth utilization
  • QOS: Support COS\DSCP, 4 queues, support WRR\SP scheduling mode
  • Security management: support ACL access control list, support 802.1X
  • Management function: support WEB, CLI, SNMP management methods
  • Monitoring and maintenance: support port mirroring, interface status monitoring, log management
  • IP40 protection grade

Specification

standard
IEEE802.3i-10BaseT, IEEE802.3u-100BaseTX/100Base-FX, IEEE802.3x-Flow Control, IEEE802.3af, IEEE802.3at IEEE802.3z-1000BaseLX, IEEE802.3ab-1000BaseTX, IEEE802.1ab, IEEE802.1D-Spanning Tree Protocol, IEEE802.1w-Rapid Spanning Tree Protocol, IEEE802.1Q -VLAN Tagging, IEEE802.1p -Class of Service, IEEE802.1X- Port Based Network Access Control etc.

Interface

DN-651154 / DN-651155 (PoE)
4 Port Gigabit RJ45+2 Port Gigabit SFP

DN-651156 / DN-651157 (PoE)
8 Port Gigabit RJ45+2 Port Gigabit SFP

DN-651158 / DN-651159 (PoE)
16 Port Gigabit RJ45+2 Port Gigabit SFP

Work environment

  • Work environment: -40~80 °C
  • storage temperature: -40~85 °C
  • relative humidity: 5%~95% (no condensation)

Power supply

  • input voltage: DC12-48V
  • Input voltage: DC48-57V (PoE Version) (Two-way power redundancy backup)
  • Access terminal: Terminal block
  • Support dual power redundancy
  • Support reverse connection protection

Mechanical characteristic

  • IP40 aluminum housing
  • DIN rail installation
  • Natural colling / No fan.

Industrial standard

  • FCC CFR47 Part 15, EN55032, Class A
  • IEC61000-4-2 (ESD): ±8kV (contact), ±12kV (air)
  • IEC61000-4-3 (RS): 10V/m (80~1000MHz)
  • IEC61000-4-4 (EFT): Power Port: ±2kV; Data Port: ±1kV
  • IEC61000-4-5 (Surge): Power Port: ±2kV/CM, ±1kV/DC;
  • Data Port: ±4kV/CM, ±2kV/DM
  • IEC61000-4-6 (CS): 3V (10kHz-150kHz); 10V (150kHz-80MHz) IEC61000-4-16 (Common mode conduction): 30V (cont.), 300V (1s) Frequency range:150kHz-80MHz
  • Impact: IEC 60068-2-27; Free Fall: IEC 60068-2-32
  • Vibration: IEC 60068-2-6

Spec table

Model No DN-651154 DN-651155
Network port 4 x 1000Mbps
SFP slot 2 x 1000Mbps
PoE Spec. NA IEEE802.3af

IEEE802.3at

Power Pin

Assignment

| NA| 1/2+;3/6-
Bandwidth| 20 Gbps
Packet Buffer

Memory

| 4.1 Mbit
Forwarding rate| 15 Mpps
Mac address table| 4 K
Max. Frame Size| 10240 bytes
Power

consumption

| < 5 watts
ESD protection| contact 8KV, air 12KV
Surge protection| CM±4KV, DM±2KV
Enclosure| IP40
Power Supply| DC12-48V| DC48-57V
MTBF| 300,000 hours
Working Temp.| -40 to 80C
Dimension (mm)| 143.710447.7
Weight (kg)| 0.7
Model No| DN-651156| DN-651157
---|---|---
Network port| 8 x 1000Mbps
SFP slot| 2 x 1000Mbps
PoE Spec.| NA| IEEE802.3af

IEEE802.3at

Power Pin

Assignment

| NA| 1/2+;3/6-
Bandwidth| 20 Gbps
Packet Buffer

Memory

| 4.1 Mbit
Forwarding rate| 15 Mpps
Mac address table| 4 K
Max. Frame Size| 10240 bytes
Power

consumption

| < 10 watts
ESD protection| contact 8KV, air 12KV
Surge protection| CM±4KV, DM±2KV
Enclosure| IP40
Power Supply| DC12-48V| DC48-57V
MTBF| 300,000 hours
Working Temp.| -40 to 80C
Dimension (mm)| 143.712547.7
Weight (kg)| 0.7
Model No| DN-651158| DN-651159
---|---|---
Network port| 16 x 1000Mbps
SFP slot| 2 x 1000Mbps
PoE Spec.| NA| IEEE802.3af

IEEE802.3at

Power Pin

Assignment

| NA| 1/2+;3/6-
Bandwidth| 56 Gbps
Packet Buffer

Memory

| 4.1 Mbit
Forwarding rate| 42 Mpps
Mac address table| 8 K
Max. Frame Size| 10240 bytes
Power

consumption

| < 15 watts
ESD protection| contact 8KV, air 12KV
Surge protection| CM±4KV, DM±2KV
Enclosure| IP40
Power Supply| DC12-48V| DC48-57V
MTBF| 300,000 hours
Working Temp.| -40 to 80C
Dimension (mm)| 175.613545.5
Weight (kg)| 1.2

Package

  • Industrial switch 1pcs
  • User manual 1pcs
  • Terminal block 1pcs

Switch Panel

Side panel: P1 and P2 are the number of connecting terminals, P+1 and P-1 are respectively to the positive and negative poles to be connected; Earthing screw used for earthing equipment.

  • DN-651154 / DN-651155 4+2 port

  • DN-651156 / DN-651157 8+2 port

  • DN-651158 / DN-651159 16+2port

Front panel: the yellow light on RJ45 port is the link light, it is on when the connection is established, and the transmission data is flashing; the green light on RJ45 port is the POE light, which is only on when the switch port supplies power to the downlink PD; green LED on is for system operation. the power indicator “POW” shows Whether the current device is received power in normal. The green LED for optical link

Switch size(mm)

  • DN-651154/DN-651155 4port: 143.710447.7mm
  • DN-651156/DN-651157 8port: 143.712547.7mm
  • DN-651158 / DN-651159 16port: 175.613545.5mm

LED Indicator

LED Indicator Status Definition

Power

| LED on| Power work in normal
LED off| No power or power in

trouble




RJ45 LED

| Yellow LED on| Ethernet work in normal
Yellow LED flashing| Link communication in

normal

Green LED on| PoE feeding to PD

device in normal

Green LED off| No PoE work
RUN| Green LED slowing

flashing

| System run in normal
Optical LED| Green LED on| Optical work in normal

Installation Caution

Installation precautions
In order to avoid damage to equipment and personal injury caused by improper use, please follow the following precautions:

  • In order to avoid damage caused by falling of the equipment, please put the equipment in a stable environment.
  • When supplying power to the equipment, pay attention to confirm the range of power supply voltage, as well as the positive and negative poles of the power supply, so as not to damage the equipment by wrong operation.
  • In order to reduce the risk of electric shock, ensure that the equipment is well grounded in the working environment.
  • No matter when, please do not arbitrarily remove the equipment shell.
  • When placing the switch, please avoid the area with dust and strong electromagnetic interference

Din rail installation
The first step is to check the grounding and stability of the guide rail: the guide rail slot of the switch is clamped into the guide rail; The second step: from the center to both sides of the guide rail positioning screws in order. Step 3: Use screws to fix the mounting rail card slot on the fixed guide groove at both ends of the guide rail to ensure that the guide rail and the switch are fixed on the guide rail vertically and stably.

grounding
Fix the grounding wire to the grounding screw above the switch, and ensure good reliable connection of the grounding system.

Power Connection
Insert the power cord into the specified position of the 6-core terminal, and insert the terminal into the standard power supply inlet (P+1 and P-1 input corresponding to the first power supply P1, and P+2 and P-2 input corresponding to the second power supply P2). The available voltage standard of the power supply is supported from 48V DC to 57V DCDIGITUS-DN-651154-L2
-Managed-Switch-fig-7

Management system Login

This series of Managed ethernet switches provides a serial port-based management system program debugging port. Located at the front of panel to log in to the command line via a standard line.DIGITUS-DN-651154-L2-Managed-
Switch-fig-8

  • Console port: baud rate 115200
  • Web IP: 192.168.10.12
  • User name: admin Password: admin
    For detail Web User Instruction, which is available on www.assmann.com

This is a Class A product. In home environment, this product may cause radio interference. In this case, the user may be required to take appropriate measures. Hereby Assmann Electronic GmbH, declares that the Declaration of Conformity is part of the shipping content. If the Declaration of Conformity is missing, you can request it by post under the below mentioned manufacturer address

  • www.assmann.com ASSMANN Electronic GmbH Auf dem Schüffel 3 58513 Lüdenscheid, Germany

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals