LS090HSV5
Single Zone High Efficiency Wall Mounted
Outdoor Unit (ODU) – LSU090HSV5,
Indoor Unit (IDU) – LSN090HSV5
Performance:
Cooling:
Cooling Capacity
(Min~Rated~Max) (Btu/h)| 1,023 ~ 9,000 ~ 12,625
---|---
SEER2| 23.2
EER2| 14.5
SEER – Seasonal Energy Efficiency Ratio| EER – Energy Efficiency Ratio
---|---
Heating:
Heating Capacity
(Min~Rated~Max) (Btu/h)| 1,023 ~ 10,900 ~ 17,061
---|---
HSPF2
Max. Heating @ Indoor 70°F DB| 10.2
Outdoor 19°F DB / 17°F WB| 11,080 (102%)
Outdoor 6°F DB / 5°F WB| 9,570 (88%)
Outdoor -3°F DB / -4°F WB| 8,310 (76%)
HSPF – Heating Seasonal Performance Factor Cooling Nominal Test Conditions:|
Heating Nominal Test Conditions:
---|---
Indoor: 80°F DB / 67°F WB| Indoor: 70°F DB / 60°F WB
Outdoor: 95°F DB / 75°F WB| Outdoor: 47°F DB / 43°F WB
Outdoor Unit:
MOP (A) | 15 |
---|---|
MCA (A) | 10 |
Cooling / Heating Rated Amps (A) | 7.8 / 7.8 |
Compressor (A) | 7 |
Fan Motor (A) | 0.4 |
MOP – Maximum Overcurrent Protection | MCA – Minimum Circuit Ampacity |
--- | --- |
Total Power Input:
Cooling Power Input (kW) | 0.62 |
---|---|
Heating Power Input (kW) | 0.71 |
Piping:
Liquid Line (in., O.D.) | ø1/4 |
---|---|
Vapor Line (in., O.D.) | ø3/8 |
Additional Refrigerant (oz./ft.) | 0.22 |
Min. / Max. Pipe Length (ft.)² | 9.8 / 82 |
Piping Length (no add’l refrig., ft.) | 41 |
Max. Elevation (ft.) | 49.2 |
Controls Features:
• 24-Hour on/off timer
• 4-Way auto swing
• Auto changeover
• Auto restart
• Jet cool/Jet heat
• Built-in low ambient standard, down to 14°F (cooling mode)| • Condensate
Sensor Connection
• Inverter (variable speed compressor)
• IDU compatible with Multi F ODUs
• Smart Diagnosis
• 3M Micro Filter| • Self-cleaning indoor coil
• Sleep mode
• Cooling only function
• Built-in Wi-Fi via ThinQ app
• Built-in base pan heater
---|---|---
Optional Accessories:
- MultiSITE™ CRC1 – PREMTBVC0
- MultiSITE CRC1+ – PREMTBVC1
- MultiSITE Comm. Mgr. – PBACNBTR0A
- PI-485 – PMNFP14A1
- Dry Contact – PDRYCB320
- LonWorks® Gateway – PLNWKB100
- AC Smart IV BACnet® Gateway – PBACNA000
- ACP IV BACnet Gateway – PQNFB17C2 Low Ambient Wind Baffle Kit
- (Cooling to 0°F) – ZLABGP01A
Operating Range:
Outdoor Unit:
Cooling (°F DB) | 14 to 118 |
---|---|
Heating (°F WB) | -4 to 65 |
Indoor Unit:
Cooling (°F WB) | 53 to 75 |
---|---|
Heating (°F DB) | 60 to 86 |
Electrical:
Power Supply (V¹/Hz/Ø) | 208-230 / 60 / 1 |
---|
System Data:
Refrigerant Type | R410A |
---|---|
Refrigerant Control | EEV |
Refrigerant Charge (lbs.) | 2.21 |
ODU Sound Pressure
(Cooling / Heating) (±1 dB[A])³| 47 / 51
IDU Sound Pressure
Cooling (H/M/L/Sleep) (±1 dB[A])³| GoldFin™
Heating (H/M/L) (±1 dB[A])³| 18.3 / 23.4
ODU Net / Shipping Weight (lbs.)| 74.1 / 78.9
IDU Net / Shipping Weight (lbs.)| 41 / 35 / 26
Heat Exchanger Coating| 41 / 35 / 25 / 21
Fan:
ODU Type | Propeller |
---|---|
IDU Type | Cross Flow |
Fan Speeds (Fan/Cool/Heat) | 6/6/2006 |
Quantity (ODU + IDU) | 1 + 1 |
Motor/Drive | Brushless Digitally Controlled/Direct |
ODU Max. Air Flow Rate (CFM) IDU Air Flow | 1,165 |
Cooling, Max/H/M/L (CFM) | 459 / 338 / 317 / 194 |
Heating, Max/H/M/L (CFM) | 2.7 |
Dehumidification (pts./hr.) | 459 / 338 / 317 / 229 |
Notes:
- Acceptable operating voltage: 187V-253V.
- Piping lengths are equivalent.
- Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745.
- All communication / connection (power) cable from the outdoor unit to the indoor unit is field supplied and is to be minimum four-conductor, 14 AWG, stranded, shielded or unshielded (if shielded, it must be grounded to the chassis of the outdoor unit only), and must comply with applicable local and national codes.
- See Engineering Manual for sensible and latent capacities.
- Power wiring cable size must comply with the applicable local and national code.
- The indoor unit comes with a dry helium charge.
- This data is rated 0 ft. above sea level, with 24.6 ft. of refrigerant line and a 0 ft. level difference between outdoor and indoor units.
- Must follow installation instructions in the applicable LG installation manual.
- Multi compatible 18k IDUs include socket adapters for refrigerant pipe connections with Multi F systems.
BACnet® is a registered trademark of ASHRAE. LonWorks® is a trademark of Echelon Corporation.
For a complete list of available accessories, contact your LG representative.
For continual product development, LG reserves the right to change
specifications without notice.
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG
Life’s Good” is a registered trademark of LG Corp. /
www.lghvac.com
Job Name/Location:……………
Date:………………………………….
PO No.:………………………………
Architect:…………………………….
Engr:…………………………………
Rep (Company): …………………
For:
File……………………………………
Resubmit…………………………..
Approval……………………………
Other………………………………..
GC:…………………………………..
Mech:……………………………….
(Project Manager)
SB_SZ_HighEfficiency
LS090HSV5_2022_11_10_122829
www.ahridirectory.org
Documents / Resources
| LG
LSU090HSV5 Single Zone High Efficiency Wall