DOMETIC GLO-A400 Area Camp Light Instruction Manual

June 13, 2024
Dometic

DOMETIC GLO-A400 Area Camp Light

Product Information

  • Battery Type: Lithium-Polymer / LiPo
  • Battery Rated Capacity: 7,000 mAh
  • Max. Power Consumption: 7.5 W
  • Input Voltage: 5 Vg, 2 A (USB-C)
  • Output Voltage: 5 Vg, 2 A (USB-A)
  • Operating Temperature: Not specified
  • Charging Temperature: Not specified
  • Color Temperature: Not specified
  • Brightness: 400 lm
  • Radio Frequency: 2.4 GHz
  • Max. Radio Frequency Power: 4 dBm
  • Dimensions (L x W x H): 130 x 90 x 130 mm
  • Weight: 550 g
  • Conformity: Not specified

Product Usage Instructions

Intended Use: The Dometic Interact device is designed for area lighting purposes.

Operation:

  1. Ensure the device is charged by connecting the USB-C input to a power source.
  2. To turn on the area light, press the POWER & CONTROL LIGHT button.
  3. Use the OUTPUT control to adjust the brightness level from 25%to 100%.

Disposal:

  • If the product contains non-replaceable batteries, rechargeable batteries, or light sources, you don’t have to remove them beforedisposal.
  • To dispose of the product, consult your local recycling center or specialist dealer for proper disposal methods in accordance withapplicable regulations.
  • The product can be disposed of free of charge.

Recycling Packaging Material:

Place the packaging material in the appropriate recycling waste bins wherever possible.

Further Product Information:

Additional product information can be accessed via the QR code on the energy label on the product or by visiting eprel.ec.europa.eu.

Legal:

Do not make any changes or modifications to the product that have not been expressly approved by the party responsible for compliance.

Contact Information:

Package Content

Dimension

Using instruction

Indicators

Operating manual

Safety instructions

!WARNING!

  • Do not expose the product to heat or fire. Do not store in direct sunlight or in a vehicle.

  • Do not use or charge the product if it is damaged. In the event of battery fluid leakage,keep away from skin and eyes. Wash any affected area with large amounts of water and seek medical attention.
    Injury hazard

  • Under abusive conditions, liquid may be ejected from the battery; avoid contact. Ifcontact accidentally occurs, flush with water. If liquid contacts eyes, additionally seek medical help. Liquid ejected from the battery may cause irritation or burn.

Intended use

This area light is suitable for:

  • Indoor use

  • Outdoor use
    The area light is not suitable for:

  • Underwater use

  • Use in environments with strong water jets

This product is only suitable for the intended purpose and application in accordance with these instructions. This manual provides information that is necessary for proper installation and/or operation of the product. Poor installation and/or improper operating or maintenance will result in unsatisfactory performance and a possible failure.

The manufacturer accepts no liability for any injury or damage to the product resulting from:

  • Incorrect assembly or connection, including excess voltage
  • Incorrect maintenance or use of spare parts other than original spare parts provided by the manufacturer
  • Alterations to the product without express permission from the manufacturer
  • Use for purposes other than those described in this manual

Dometic reserves the right to change product appearance and product specifications

Operation

Only use the product with Listed/Certified Information Technology (Computer) Equipment, a Listed/Certified ITE Power Supply, or a Listed Class 2 Power Unit. The product needs to be charged before use. Always use the suitable USB cable and refer to the manufacturer’s instructions for proper charging instructions. Only use the product with Listed/Certified Information Technology (Computer) Equipment, a Listed/Certified ITE Power Supply, or a Listed Class 2 Power Unit. End user should choose a UL Class 2 adapter.

Disposal

Recycling packaging material

Place the packaging material in the appropriate recycling waste bins wherever possible.

Recycling products with non-replaceable batteries, rechargeable batteries or light sources

  • If the product contains any non-replaceable batteries, rechargeable batteries or light sources, you don’t have to remove them before disposal.
  • If you wish to finally dispose of the product, ask your local recycling center or specialist dealer for details about how to do this in accordance with the applicable disposal regulations.
  • The product can be disposed free of charge.

Technical data

Further product information can be accessed via QR code on the energy label on the product or via eprel.ec.europa.eu.

  GLO-A400
Type de batterie : Lithium-polymère / LiPo
Puissance nominale de la batterie : 7000 mAh
Consommation électrique max. : 7,5 W
Tension d’entrée : 5 Vg, 2 A (USB-C)
Tension de sortie : 5 Vg, 2 A (USB-A)
Température de fonctionnement : -20 °Cà+45 °C
Température de charge : 0 °C à +40 °C
Température de couleur : 2700 K à 7000 K
Luminosité (« Brightness ») : 400 lm
Fréquence radio : 2,4 GHz
Puissance de fréquence radio max. : 4 dBm
Dimensions (L x l x h) : 130 x 90 x 130 mm
Poids : 550 g
Conformité :

Legal

CAUTION! Injury and material damage Do not make any changes or modifications to the product that have not been expressly approved by the party responsible for compliance.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  • This device may not cause harmful interference.
  • This device must accept any interference received, including interference that may cause undesired operation.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment

FCC

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interferenceto radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:

  • This device may not cause interference.
  • This device must accept any interference, including interference that may cause undesired operation of the device. This Class B digital apparatus complies with Canadian ICES-3(B)/NMB-3(B).

A complete list of Dometic companies, which comprise the Dometic Group, can be found in the public filings of:
DOMETIC GROUP AB

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>