Tempio Controls HY02B05 WIFI Digital Heating Thermostat User Manual

June 1, 2024
Tempio Controls

HY02B05 WIFI Digital Heating Thermostat

“`html

Specifications

  • Product: WIFI Digital Heating Thermostat

  • Features: WIFI connectivity, program modes, manual mode,
    holiday mode, external NTC sensor, child lock

  • Temperature Range: 18-22 degrees Celsius

  • Model Options: 5+2, 6+1, 7-day models

Product Usage Instructions

Features Overview:

The WIFI Digital Heating Thermostat offers various features
including program modes, manual mode, holiday mode, and more. It
allows you to control your heating system remotely using the
Smartlife app.

Installation and Wiring:

Refer to the provided wiring diagrams for electric heating and
water heating installations. Ensure proper connections are made
according to the instructions to avoid any issues.

Display Icons and Functions:

The thermostat displays various icons indicating program mode,
manual mode, clock, holiday mode, heating status, WIFI connection
status, child lock, and more. Familiarize yourself with these icons
for easy operation.

Operation Keys:

Use the operation keys A, B, C, D, and E for different functions
such as turning the thermostat on/off, switching modes, setting
time, adjusting temperature, and more. Refer to the user manual for
detailed key functions.

Program Mode Setting:

Choose from different model options like 5+2, 6+1, or 7-day
models for programming periods. Long press to enter program mode
setting and adjust settings such as hour, minute, time period, and
data. Ensure to save settings properly.

Advanced Options:

Access advanced options by long-pressing in the power-off state.
Navigate through options A1 to AE to set features like temperature
calibration, temperature difference, child lock settings, and more.
Follow the instructions carefully for configuration.

FAQ (Frequently Asked Questions)

Q: How do I connect the thermostat to WIFI?

A: To connect the thermostat to WIFI, download the Smartlife app
from Google Play or App Store. Turn on the thermostat and activate
WIFI distribution network icon to establish a connection.

Q: What is the optimum comfort temperature range?

A: The optimum comfort temperature range is between 18 to 22
degrees Celsius.

Q: How do I set the thermostat to holiday mode?

A: To set the thermostat to holiday mode, long press the confirm
key for 3-5 seconds and follow the instructions on the display to
set holiday days and temperature.

Q: How can I access advanced options for configuration?

A: In the power-off state, long press for 3-5 seconds to access
advanced options. Navigate through options A1 to AE to configure
settings such as temperature calibration, child lock, and more.

“`

WIFI Digital Heating ThermostatUser Manual

Many thanks for your selection of our products and services, and also for your trust and

support to us.

Search for “Smartlife” from google play or App Turn on the thermostat, press and hold the

store to Download the Wifi App

key combination ” “and” ” Activate

WIFI distribution network icon

Features
(A) Includingbuilt-in sensor and external sensor (B) 0.5°C accuracy keeps temperature within the level you set. (C) Children lockto prevent misoperation by children (D) Data memory when power is off. (E) Holiday mode make you enjoy more comfortable temperature in holiday (F) The temperature of external sensor can be checked Product Specifications Power: 90-240Vac 50/60HzRange of temperature display:1~70°C Display accuracy:0.5°CInsulating condition: Normal environment Probe sensor:NTC(10k)1%Running program: Set per 1 week as a cycle Contact capacity:3A/(WW);16A/(WE)Output: Switch relay Limit temperature range:1~70°CInstallation: recessed type (in the wall) Range of temperature adjustment:5~35°C Size(mm)868627
Wiring Diagram

Electric heating wiring diagram Water heating wiring diagram (do not connect terminal “close 4” of electric valve)
Water heating and gas wall-hung boiler heating, nocontact wiringdiagram,(disconnection when electric valve close) Note:5&6 connect with gas boiler ,3&4 connect with N and L line . If normally closed thermal actuator ,then connect with 1&3,if normally open thermal actuator ,then connect with 2&3

Displays

Description of icon

Programmode;run preset program Manual mode

Temporary manual mode Clock

Holiday mode, Holiday days and temperature can be set to run in countdown mode

/ Heating,,icondisappearsto stop heating /

External NTC sensor

WIFI connection, flashing EZ distribution mode Child lock

Wifi status: Disconnection

Cloud icon: flashing AP distribution network mode

:Cooling mode,this icon is always displayed when switching to cooling mode and flashes

when the cooling load is output Operation key NO symbols represent

A

Turn ON/OFF:Short press to turn on/ turn off

B

1 Short press to switch program mode and manual mode

2 Turn on thermostat, long press for 3-5 seconds to enter into programmode setting

3.Turn off thermostat, long press for 3-5 seconds to enter into advancedoption A

C

1 Confirm key: use it with key 2 Only short pressit to set time

3 Turn on thermostat,long press it for 3-5seconds to holiday mode setting. Appear

OFF, press or change to ON,then press to confirm opening holiday mode

4 Turn off thermostat ,long press it for 3-5s to enter into advanced option B

D

1 Decrease key

2 Long press to lock /unlock keys

E

1 Increase key ; 2 Long press to inquire external sensor temperature ( only available for BN item select N3 in the advance option B) 3 In the program model, press

or enter to temporary manual mode

Program mode setting

5+2 (factory default),6+1 and 7 models 6 times period setting for user choose. In the advanced option A choose model of you need, under power on state, long press for 3-5 seconds enter into programming

mode setting, then short press choose: hour,minute, time period, and press and data, finished setting, about 10 seconds will automatic save and exist.

to adjust

Wake up

Leave home Back home Leave home Back home Sleep

600 20 800 15 1130 15 1330 15 1700 15 2200 15

The optimum comfort temperature is 18-22.
Advanced option A

Power off state, long press for 3-5 seconds to access advanced option A.

From A1 to AE, short press to choose the option, and adjust data by , , short press to switch

next option.Remain about 5 seconds after finish setting will quit setting.

NO

Setting Options

Data Setting Function

Factory Default

A1

Measure Temperature Calibration

-9-+9(Displayed as temperature value)

the

corrected

room

-1

Start/stop working

A2 temperature difference 0.5-2.5

1

setting

A3 Child lock setting

0:half lock 1:full lock

0

Power on/off state

0:Thermostat on/off with memory whenel 0

A4

memory after electricity ectrify

cut

1:Thermostat off when electrify

2:Thermostat on when electrify

A5 Backlight show time

5~30s

10

0: 5+2

A6 Program mode type

1: 6+1

0

2: 7

A7

Setting temperature minimum limit

1-10°C

5°C

A8

Setting temperature maximum limit

20-70°C

35°C

A9

Low temperature protection

1-10°C

When setting temp = 10, if press will

5°C

display –, cancel low temperature protection

High temperature AA protection for external
sensor

20°C-70°C

When setting temp =20°C, , if press

will

display — , cancel hightemperature

protection

45°C

AB

High temperature protection temperature

1-9°C

2°C

difference setting

AC

Window function triggers temperature

10-20°C,setting temperature is 10°C,decrease

it ,will display–,then canceled this function

AD

Window function running time

10-20min

10

AE Restore factory defaults Display Ao , long press key to whole show

AF Mode select

0:Heating 1:Cooling

0

Advanced option B

Power off state, long press for 3-5 seconds to access advanced option B. short press to choose the option, and adjust data by , , short press option.Remain about 5 seconds after finish setting will quit setting.

to switch next

NO

Setting Options

Data Setting Function

Factory Default

BN Sensor type

BC

Descaling function

N1:Internal sensor (high temperature

protection close)

N2:External sensor (high temperature

protection close)

N3:Internal sensor control

N1

temperature ,external sensor limit temperature

(external sensor detect the temperature is

higher than highest temperature ofexternal

sensor, thermostat will Closerelay,turn off load)

0:Disable descaling function

1:Enable descaling function

0

Bo Product information

Can’t be changed

Return difference: limit valve of external sensor is 45 for factory default (A6),value of external
sensor control return difference (AB) is 2. when temperature rise to 45,then relay stop working and will remind high temperature production alarm. If temperature decline to 43relay continue to work and heating alarm will be relieved. (itcan be operated ,only when room temperature is lower than setting temperature )
Sensor fault display:please choose correct working way of built-in and external sensor, if choose
wrongly or sensor fault (breakdown), “E1” or “E2” will be displayed on the screen. Thermostat will stop heatinguntil the fault is eliminated Warranty We offer the warranty of 18 months, from the sales day. The products of our company can have lifetimewarranty ,if it is not the quality problems, or beyond the warranty period, we will charge for the after-saleservice.

Installation diagram:

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals