PSA Products 6000THL Lifesaver Smoke Alarm Remote Control User Guide

June 13, 2024
PSA Products

PSA Products 6000THL Lifesaver Smoke Alarm Remote Control

Thank you

Thank you for purchasing this PSA Lifesaver Smoke Alarm Remote Control
NOTE: Please thoroughly read this User Guide and save the document for future reference and to pass on to any subsequent owner.
Important: Please read this user guide before installation.

Introduction

The Smoke Alarm Remote Control model 6000 THL allows compatible Lifesaver Smoke Alarms to be conveniently tested, hushed and located. It has a memory feature and status indication. This controller is wireless and will provide home owners with a more convenient method to identify which smoke alarm has activated, easily silence alarms and also promote regular testing of smoke alarms. The Smoke Alarm Remote Control will only control compatible 240VAC mains powered smoke alarm models that are mounted on the 6000WB Wireless Base.
Important: Only compatible smoke alarms will operate with the remote control.
Failing to use the correct smoke alarm and accessories may render the system inoperable.

Compatible Models
Smoke Alarm 6000DCW, 6000, 6000RL, 6000W, 6000RLW
Wireless Base 6000WB

One Smoke Alarm Remote Control can operate up to 23 smoke alarms on a wireless system.

The wireless signal uses radio frequency to create an interlinked network of smoke alarms. When one smoke alarm activates, it will trigger other smoke alarms within the same wireless network. The Smoke Alarm Remote Control will test, hush and locate smoke alarms within the same wireless network.

Feature

Technical Specification

Power: Lithium 10 year battery
Radio Frequency: 918 MHz
Wireless Range: 100 meters open air. 30m indoors.
Operation: Up to 23 units
Temperature : 0°C– 40°C
Humidity: 0 – 93% (non-condensing)
Service Life : 10 years from installation
Approval: AS/NZS 4268:2017
AS/NZS 3786: 2014 (Selected Clause)
AS/NZS CISPR 32: 2015
AS/NZS 62368.1: 2018
AS/NZS 2772.2: 2016 AMD 1:2018

This product has an expected service life of 10 years under normal conditions. We recommend that you should replace the product after 10 years from installation date to ensure normal operation.

Installation

The Remote Control can be mounted either on a wall bracket, or directly on the wall.
a. To mount the Remote Control directly on the wall.
1. Remove the back cover of the remote using a small flat blade screwdriver at the bottom of the Remote Control.
2. Fix the back cover on the wall using screws provided.
3. Fit the Remote Control back into its back cover.

b. Mounting Bracket.
The Remote Control can be mounted onto a wall bracket. Mount the remote bracket on the wall, then slide the Smoke Alarm Remote Control into the bracket.

Programming the Network

Before using the Remote Control, the unit needs to be programmed to an existing wireless network of smoke alarms.

Definitions:

OOB: Out Of Box. Factory Default status. When first turned ON, an OOB device will auto-search and join an existing wireless network.
Standby: Normal mode, connected to a wireless network. Stand alone: Not connected to a network. Stand alone mode.

New Wireless Network Setup

If you are joining this Remote Control at the same time as other new wireless smoke alarms, then follow the setup procedure in the wireless smoke alarm
User Guide as well.Z

  1. First, create or open a wireless network of smoke alarms before joining the smoke alarm control.

  2. Slide the power switch (at the back of the Remote) to ON position. The Remote will automatically search for a wireless network; its red LED will flash ON and OFF every alternate second.
    When the Remote has successfully joined a wireless network, its LEDs will light up in a rotating sequence.

  3. Close the network on the smoke alarms by pressing 6000THL or 6000DCW or 6000WB button 2 times. And then all RF devices will go into stand by mode. The network will also timeout after 15 minutes and automatically close. But if it didn’t connect to any network after 15 minutes, the Smoke Alarm Remote Control will go into Stand Alone mode and the Green LED will flash twice every 30 seconds. NOTE: It is recommended to first create the wireless smoke alarm network. Then use the Push To Test (PTT) to confirm it is working properly (See wireless smoke alarm User Guide). And then join this Remote as an additional device in the wireless network.
    NOTE: The 6000THL Remote Control cannot be set as a Coordinator.

  4. Smoke Alarm Remote Control Network Setting Reset network: To clear the wireless network settings in the Remote Control, open the network by pressing its button 4 times. Then press and hold the button for 8 seconds. Release the button immediately when the Red LED flashes rapidly. After the Remote is reset, the unit will go to Stand Alone mode.
    Stand Alone mode to Network Search mode: Press the 6000THL button twice to change from Stand-Alone mode to Network Joining mode.
    Open a network: When the Remote is in Standby mode, press the button 4 times to open the wireless network.
    View the number of network devices: Press and release the Remote Control button when the network is in open mode to view the number of network devices.
    The number of Red LED flashes denote the number of wireless devices.
    Close a network: Press the corresponding button twice on any interconnected wireless device to close the network

Operation

Test Function
Press and release the Button, the Red LED will start flashing. All the interconnected smoke alarms in the wireless network will sound.
Allow up to 20 seconds for the interconnected smoke alarms to respond to this Test function.
Low Battery HUSH
If a smoke alarm is in low battery condition, the low battery beeping can be hushed for 8-24 hours.
This feature will allow the user to attend to the smoke alarm at a more convenient time.
Test Fault
If the smoke alarm network fails to respond to the Test function, the amber Fault LED of the Remote Control will flash seven times in 2-cycles to indicate Test Fault.

Locate and Hush Function

While the smoke alarms are sounding, the Locate function will identify the initiating smoke alarm. Press and release the Button to silence all interconnected smoke alarms for 2 minutes. However, the initiating smoke alarm will continue to sound. The green LED on the Remote Control will flash once every two seconds. Locate mode will automatically timeout after 2 minutes; or if the smoke has cleared.
Press and release the Button again to hush the initiating smoke alarm. The green LED of the Remote Control will flash 4 times quickly and then extinguish. The Hush mode will auto-exit after 9-10 minutes.

  • Important: To Hush the smoke alarms, the initiating smoke alarm must first be located.

Alarm Memory

The LifeSaver 6000-series 240VAC Smoke Alarms have an audible Alarm Memory function. This function indicates if a smoke alarm had sounded in the past 24-hour period. The Memory red LED will flash 3-times every 40 seconds, if there had been an Alarm Memory event.
To identify which smoke alarm had sounded, press the Button and the corresponding 240VAC wireless smoke alarm will chirp continuously for 3 minutes; or until the button is pressed again. Then both the THL-controller & initiating Smoke Alarm will reset their Alarm Memory mode.
It is recommended to test the alarms and remote control monthly.

Remote Control Status and Visual Indicators

Status Visual Indicators Description or Action:
Network Search Red LED (top) flashes 1 sec On & 1 sec Off Remote

Control searching for an opened wireless network to join.
Stand-alone| Green LED flashes twice every 30 sec.| Not connected to any network. Press button twice to start searching for a network to join.
Stand By| Green LED flashes once every 60 sec.| Normal operating mode. Remote Control on Standby, waiting for user action.
Network found & device joined as RFD| LEDs flash in circular pattern (Red→Green→Red →Amber→Blue.)| Remote Control joined successfully to wireless network.
Reset Device (during join mode)| Red LED flashes rapidly; then Off| Press and hold the button for 8 seconds. Release the button immediately when Red LED flashes rapidly. After the Remote is reset, the unit will go into Stand Alone mode.
Open a network| LEDs flash in circular pattern (Red→Green→Red →Amber→Blue).| Network has been opened. To open the network, press button 4 times while in Standby mode.
Close a network| All LEDs stop flashing.| To close the network, press button twice while network is open.
View the number of network devices| Top red LED flash the number of network devices| Press & release button while network is open
Test| Red LED flashes 6 times repeatedly (in two groups of three flashes).| In Standby mode, press & release Button to initiate Test mode. All interconnected smoke alarms will sound within 20 seconds.
Alarm (smoke)| Red LED flashes 6 times repeatedly (in two groups of three flashes).| When the network is in alarm condition.
Locate| Green LED flashes once every 2 sec| Press the button to locate the initiating smoke alarm while the system is in alarm. Auto cancels after 2 minutes, or if alarm event has cleared.
HUSH| Green LED flashes 4 times quickly, then Off.| During alarm locate, press the button again to silence the alarms for 9-10 minutes.
Smoke Alarm Memory| Red LEDs (“Memory” on Remote Control and also initiating smoke alarm) flash 3 times every 40 sec| NOTE: Alarm memory is only retained for 24 hrs.
Alarm Memory Locate| Red LEDs flash quickly. (“Memory” on Remote Control and also initiat- ing smoke alarm).| Press the Button to locate the initiating 240VAC wireless smoke alarm. Press button again to exit. Or will auto timeout in 3 minutes.

Troubleshooting Table

Status Visual Indicators Description or Action
Not Joined Green LED flashes twice every 30 sec Standalone mode.

Press the button twice to open the network to join the Remote Control.
Low Battery| Amber LED flashes every 30 sec| Battery Voltage is low. Please dispose of the remote control and replace with a new one.
Drop out network| Amber LED flashes every 2 sec| Loss of network connection. Perform Power Reset by turning Off the rear switch and then On again. Then press Button 4 times to start searching for network to join.

Service and Warranty

If after reviewing this manual you feel that your product is defective in any way, do not tamper with the unit. Return it for servicing to: PSA Products Pty Ltd of 17 Millicent Street, Burwood Victoria 3125 (See Warranty for in- warranty returns).

  1. PSA Products Pty Ltd (ABN: 99 076 468 703) of 17 Millicent Street, Burwood 3125 Victoria, Australia warrants this product for a period of two (2) years from the date of purchase, as reflected on the Authorized Reseller’s or Distributorʼs invoice / receipt provided to you. PSA Products Pty Ltd will repair or replace the product (at the option of PSA Products) due to any manufacturing defect, at the cost of PSA Products Pty Ltd (excluding any lab our costs relating to removal or re installation of product, and transport costs).
  2. This warranty shall not apply to the product if it has been damaged, modified, abused or altered after the date of purchase, or if it fails to operate due to improper maintenance.
  3. To the extent permitted by law, the liability of PSA Products Pty Ltd arising from the sale or under the terms of this limited warranty shall not in any case exceed the cost of replacement and subject to this clause. In no case shall PSA Products Pty Ltd be liable for consequential loss or damages resulting from the failure of the product or breach of this, or: Any other warranty, express or implied, loss or damage caused by failure to abide by the instructions supplied in the leaflets.
  4. To the extent permitted by law, PSA Products Pty Ltd., makes no warranty, expressed or implied, written or oral, including that of merchantability or fitness for any particular purpose, with respect to the consumer replaceable battery if any. A product with non-serviceable built-in battery is covered under warranty of the product.
  5. This warranty is provided in addition to other rights and remedies you have under law: Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. What constitutes a major failure is set out in the Australian Consumer Law.

Warranty Registration

Register this product for warranty to ensure fast and efficient service. Please visit our websitehttps://www.psaproducts.com.au/register-product/ to register. It is important to register your product. It will ensure your investment is protected in case it is damaged or broken and we can effectively carry out any warranty claims. Registration will also allow us to contact you in an unlikely event of product safety notification required under Consumer Product Safety Act. Registration will also help us improve our product design to meet your needs.

Another Quality Product By: PSA Products Pty Ltd 17 Millicent Street, Burwood, Victoria 3125, Australia Ph: (03) 9888 9889
Email:[email protected]
Website:www.psaproducts.com.au

Quick Setup for New Wireless Network

Step 1. Refer to the smoke alarm wireless setup.

Please read through 6000WB, 6000DCW for Interlink Network Setup.

NOTE: It is recommended to create the wireless smoke alarm network first and do Push to test (PTT) to confirm it works properly. Then join the Smoke Alarm Remote Control as an additional device in the wireless network.
Please Note: The smoke alarm controller will only operate on smoke alarms with wireless RF interlink.

Step 2. Open wireless network on the smoke alarms. Refer to smoke alarm user guide.

Refer to 6000DCW and 6000WB user guide to open the wireless network.

Step 3. Slide power switch to ON position at the back of remote.

  1. Slide power switch to ON position
    The remote will search network automatically with red LED flash 1 second ON and 1 second OFF.

  2. The Remote Control has joined successfully
    When the Remote Control has successfully joined the network, its LEDs will flash in a circular pattern (RED → Green → Red → Amber → Blue).
    Close the wireless network by pressing the Remote Control button twice