JASCO ZWN4015 In-Wall Smart Switch User Guide
- June 13, 2024
- JASCO
Table of Contents
JASCO ZWN4015 In-Wall Smart Switch
Instructions made easy
- Read instructions or watch easy-to-follow video.
- Scan code or visit byjasco.com/76596i.
Register your product
- Receive exclusive deals and register your product.
- Scan code or visit byjasco.com/deals.
WARNING — SHOCK HAZARD CHANGE PADDLE
This step is optional. Before installation, you may want to change the paddle
to:
- Lift the air gap tab at the base of the paddle
- Push the side tabs in on one side followed by the other to release paddle and lift it from the device
- Insert the air gap and side tabs and snap the new paddle into place
REMOVE SINGLE-POLE SWITCH
- Shut off power to the circuit at the circuit breaker or fuse box
- Remove wallplate
- Remove the switch mounting screws
- Carefully remove the switch from the wires. DO NOT disconnect the wires.
- Identify the following wires in the switch box:
- A. LINE – Black wire/black screw (input)
- B. LOAD – Black wire/black screw (output)
- C. GROUND – Green or bare wire/green screw
- D. JUMPER – White wire/silver screw
CHANGE LED INDICATOR COLOR
The LED indicator color can be changed from the device:
- Press menu button for five seconds
- LED illuminates in selected color
- Press top or bottom paddle to cycle through color options:
INSTALL THE WALLPLATE
Insert wires into holes, DO NOT wrap wires around screws, DO NOT remove
screws.
Like our product?
- Leave a review on your favorite retailer website or amazon.com.
- For additional JascoPro Series products, visit our website www.jascopro.com.
- Having problems? Let us know how we can help.
- Call 1-800-654-8483 between 7AM-8PM, M-F, Central Time.
ADDING YOUR DEVICE TO A Z-WAVE NETWORK
- Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave network.
- Once the controller is ready to add your device, press the top or bottom of the rocker.
You have complete control to turn your fixture ON/OFF according to groups, scenes, schedules, and interactive automations programmed by your controller. If your Z-Wave certified controller features remote access, you can control your fixture from your mobile devices. If prompted by the controller to enter the S2 security code, refer to the QR code/security number on the side of the box or the QR code label on the product (see Figure 1). Enter the 5-digit code.
Figure 1:
- DSK : XXXXX -25651-22671 -26939-47599 -19612-25872 -47752
- Z-WAVE DSK PIN: XXXXX
TO REMOVE AND RESET THE DEVICE
- Follow the instructions for your Z-Wave certified controller to remove a device.
Thank you for your purchase!
Instructions made easy
Read instructions or watch easy-tofollow video.
Scan code or visit byjasco.com/76596i.
Register your product
Receive exclusive deals and register your product.
Scan code or visit byjasco.com/deals.
For additional JascoPro Series products, visit our website www.jascopro.com.
-
Like our product?
Leave a review on your favorite retailer website or amazon.com. -
Having problems?
- Let us know how we can help.
- Call 1-800-654-8483 between 7AM-8PM, M-F, Central Time.
ADDING YOUR DEVICE TO A Z-WAVE NETWORK
- Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave network.
- Once the controller is ready to add your device, press the top or bottom of the rocker.
You have complete control to turn your fixture ON/OFF according to groups, scenes, schedules and interactive automations programmed by your controller.
- If your Z-Wave certified controller features remote access, you can control your fixture from your mobile devices.
- If prompted by the controller to enter the S2 security code, refer to the QR code/security number on the side of the box or the QR code label on the product (see Figure 1). Enter the 5-digit code.
TO REMOVE AND RESET THE DEVICE
- Follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave network.
- Once the controller is ready to remove your device, press the top or bottom of the rocker.
TO RETURN YOUR SWITCH TO FACTORY DEFAULTS
- Pull up the air gap switch.
- While pressing the OFF (bottom) button, push in the air gap and continue pressing the OFF button. The LED flashes through the eight colors once.
NOTE:
This should only be used if your network’s primary controller is missing or
otherwise inoperable.
NOTE:
SmartStart enabled products can be added into a Z-Wave network by scanning the
QR code on the product with a controller providing SmartStart inclusion. No
further action is required and the SmartStart product will be added
automatically within 10 minutes of being switched on in the network vicinity.
SPECIFICATIONS
IMPORTANT!
ZWN4015
- Power: 125VAC, 60Hz
- Maximum loads: 960W incandescent, 1/2HP motor or 1800W (15A) resistive
- Signal (frequency): 908.4MHz,908.42MHz,916MHz,912MHz,920MHz
- Range: Up to 150ft. line of sight between the wireless controller and the closest Z-Wave receiver module
- Operating temperature range: 32-104° F (0-40° C)
- Type 1 enclosure, independently mounted (vertical position only), operating control: type 1.B action, pollution degree (2), impulse voltage (2500V), software class A
- Specifications subject to change without notice due to continuing product improvement
FEATURES
IMPORTANT!
The fixture controlled by the Z-Wave in-wall smart switch must not exceed
switch ratings. The switch is designed only for use with permanently installed
fixtures.
Get to you know your Z-Wave smart switch
-
Turn ON/OFF manually or remotely through the Z-Wave controller
-
Can be added in multiple groups and scenes
-
Auto-detect line/load terminals
-
May be used in single-pole installation or 3-way wiring configurations
-
Compatible with all LED, CFL, incandescent and halogen lights
-
Interchangeable paddle
-
Uses a standard, rocker-style wallplate for single-gang installations (wallplate not included)
-
Multicolor LED indicates switch location in a dark room
-
Screw terminal installation – requires wiring connections for line (hot), load, neutral and ground. Traveler wire required for 3-way installation
-
This Z-Wave device has advanced features that allow you to customize your experience. These features can only be adjusted by a Z-Wave enabled controller that supports the Z-Wave configuration command class. For a complete list of adjustable configurations, visit www.ezzwave.com/config.
-
A. Ground (Green/bare)
-
B. Line or load (Black)
-
C. Line or load (Black)
-
D. Traveler (Red/other)
-
E. Neutral (White)
-
F. Top rocker — press to turn ON device
-
G. Bottom rocker — press to turn OFF device
-
H. Menu button
-
I. Air gap switch — pull the air gap switch out to disconnect the power. Push it all the way back in for normal operation.
WARNING — SHOCK HAZARD
Turn OFF the power to the branch circuit for the device and lighting fixture
at the service panel. All wiring connections must be made with the power OFF
to avoid personal injury and damage to the device. This device is intended for
installation in accordance with the National Electric Code and local
regulations in the United States or the Canadian Electrical Code and local
regulations in Canada. If you are unsure or uncomfortable about performing
this installation, consult a qualified electrician.
CHANGE PADDLE
This step is optional. Before installation, you may want to change the paddle to match your wallplate or décor
- Lift the air gap tab at the base of the paddle
- Push the side tabs in on one side followed by the other to release paddle and lift it from the device
- Insert the air gap and side tabs and snap the new paddle into place
REMOVE SINGLE-POLE SWITCH
-
Shut off power to the circuit at the circuit breaker or fuse box
IMPORTANT! Verify power to switch box is OFF before continuing -
Remove wallplate
-
Remove the switch mounting screws
-
Carefully remove the switch from the switch box – DO NOT disconnect the wires
-
Identify the following wires in the switch box:
- A. Ground – Green/bare
- B. Line (hot) – Black (connected to power)
- C. Load – Black (connected to lighting)
- D. Neutral – White
-
Disconnect the wires from the existing switch – label wires according to the previous terminal connections
SINGLE-SWITCH WIRING
WIRING REQUIREMENTS
- Attach using the enclosure’s holes, strip insulation 5/8in. (16mm).
- UL specifies the tightening torque for the screws is 12lbf-in (14Kgf-cm).
-
Connect green/bare wire to the GROUND terminal
-
Connect the black wire from the light to either LINE/LOAD terminal
-
Connect the black wire from the power source (hot) to the other LINE/LOAD terminal
-
Connect the white wire to the NEUTRAL terminal – use jumper if necessary
NOTE: The traveler terminal is only used for multi-switch wiring and is not used in a two-way system (one switch and one load) -
Secure the device into the switch box with the provided mounting screws – ensure wires are not pinched or crushed
-
Install the wallplate
CYCLE LED
The LED below the switch acts as a guide light or status indicator.
How to cycle through options:
- Press menu button for five seconds
- Press up three times and down one time quickly – indicator flashes blue
- Push the top paddle:
- A. Once for LED ON when the load is OFF – illuminates orange to confirm
- B. Twice for LED ON when the load is ON – illuminates yellow to confirm
- C. Three times for always OFF – illuminates pink to confirm
- D. Four times for always ON – illuminates purple to confirm
- Press menu button once to save – indicator flashes green twice
CHANGE LED INDICATOR COLOR
The LED indicator color can be changed from the device.
- Press menu button for five seconds
- Press top paddle once and bottom paddle once – LED illuminates in selected color
- Press top or bottom paddle to cycle through color options:
- Red
- Orange
- Yellow
- Green
- Blue (default)
- Pink
- Purple
- White
- Press menu button once to save – indicator flashes green twice
- Insert wires into holes, DO NOT wrap wires around screws
- DO NOT remove screws
STANDARD 3-WAY SWITCH WIRING
IMPORTANT!
The Z-Wave device operates with add-on switches by default. To install it with
a standard 3-way switch, follow the steps under 3-way configuration. The
instructions below are for wiring a standard 3-way switch. See the add-on
switch manual to install add-on switches.
LINE SIDE (Z-WAVE DEVICE)
- Shut off power to the circuit at the circuit breaker or fuse box
- Remove line side wallplate
- Remove switch from line side switch box – DO NOT disconnect wires
- Label wire from the power source LINE
- Label one remaining wire traveler 1 – note the color of this wire for installation of the 3-way switch
- Label the other remaining wire traveler 2
- Disconnect all wires from the switch
- Connect green/bare wire to the GROUND terminal
- Connect the line wire to either LINE/LOAD terminal
- Connect the traveler 1 wire to the other LINE/LOAD terminal
- Connect the traveler 2 wire to the TRAVELER terminal
- Connect one end of a jumper to the bundle of neutral wires using a wire nut
- Connect the other end of the jumper to the NEUTRAL terminal
- Secure the device into the switch box with the provided mounting screws – ensure wires are not pinched or crushed
- Install the wallplate
LOAD SIDE (3-WAY SWITCH)
- Remove load side wallplate
- Remove switch from load side switch box – DO NOT disconnect wires
- Label wire from the light LOAD
- Label traveler 1 wire – recall the wire color from the Z-Wave device installation
- Label traveler 2 wire
- Disconnect all wires from the switch
- Connect green/bare wire to the GROUND terminal
- Connect the load wire to the traveler 1 wire using a wire nut
- Connect traveler 2 to the LINE (hot) terminal
- Connect one end of a jumper to the bundle of neutral wires using a wire nut
- Connect the other end of the jumper to the COMMON terminal
- Secure the 3-way switch into the switch box – ensure wires are not pinched or crushed
- Install the wallplate
- Apply power to the fuse box or circuit breaker
Scan code for alternate 3-way wiring process
WARNING
- RISK OF FIRE
- RISK OF ELECTRICAL SHOCK
- RISK OF BURNS
CONTROLLING APPLIANCES
- THIS SWITCH IS RATED FOR AND INTENDED TO ONLY BE USED WITH COPPER WIRE
- USE 14AWG OR LARGER WIRES SUITABLE FOR AT LEAST 90ºC FOR SUPPLYING LINE (HOT), LOAD, NEUTRAL, GROUND AND TRAVELER CONNECTIONS
- DO NOT EXCEED RATINGS
- DO NOT USE TO CONTROL ANY DEVICE WHERE UNINTENDED OPERATION COULD CAUSE UNSAFE CONDITIONS (HEAT LAMP, SUN LAMP, ETC.)
- NOT FOR USE WITH MEDICAL OR LIFE-SUPPORT EQUIPMENT
- FOR INDOOR USE ONLY
FCC/IC
Suppliers Declaration of Conformity | Model #: 76596 | Jasco Products Co., 10 E. Memorial Rd., Oklahoma City, OK 73114, www.byjasco.com.
This device complies with Part 15 of the FCC and Industry Canada license- exempt RSS standards. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
FCC NOTE:
The manufacturer is not responsible for any radio or TV interference caused by
unauthorized modifications to this equipment. Such modifications could void
the user’s authority to operate the equipment
NOTE:
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.