RainWise IP-100TM Network Interface User Guide
- June 12, 2024
- RainWise
Table of Contents
IP-100™
Network Interface
User’s Guide
Rev Date: 7/08/14
RainWise IP-100 Users Guide
2014 Revision
Copyright © 2014 by RainWise, Inc.
All rights reserved. No part of this work may be reproduced in any form except
by written permission of the publisher. All rights of translation are
reserved.
RainWise IP-100 is a trademark of RainWise, Inc.
Introduction
The IP-100 network interface facilitates a way of gathering and transmitting
weather data to multiple formats over a network connection. RainwiseNet is our
web data hosting service designed to monitor and forecast weather data
received from RainWise weather stations.
RainwiseNet also provides live links to many other online weather portals,
including Weather Underground, to share data. IPhone and Android apps are also
available to view your data anytime, anywhere.
Getting Started
The IP-100 is available for both the MK-III LR and MK-III (418/433 MHz)
weather stations. LR models have the radio receiver built into the IP-100. The
418/433 MHz versions require an external radio receiver. An external receiver
can be provided for the LR models, contact service if needed.
2.1) Powering Up
LR Weather Stations
- Connect power using the power supply provided.
- Connect the IP-100 to your network using the Ethernet cable provided with the unit. You may use your own cable with a maximum length of 100 feet. Do NOT disconnect for at least10 minutes after first power up.
418/433 MHz Weather Stations
- Connect the IP-100 to the network using the Ethernet cable provided with the unit. You may use your own cable with a maximum length of 100 feet.
- Connect the separate black receiver module to the IP-100 using the silver “phone” cable provided.
- Apply power to the IP-100 using the power supply provided.
2.2) Verifying Communication of Your IP-100
LED Lights (Both Models)
- Radio Data Light: This LED will blink red indicating its receiving data from a weather station. If this light doesn’t blink your IP-100 could be out of range of a weather station. This light should flash every two seconds. If it takes longer to flash you may have a weak signal.
- Green Light: A green light should appear by the Ethernet port, letting you know you’re connected to the network.
- Yellow Light: This LED by the Ethernet port should blink indicating data being collected.
- Ethernet Light: The Ethernet LED will light while the IP-100 logs onto the network. This light should go out after a few seconds. It will then turn on every time it sends data to RainwiseNet for 2-3 seconds. This may be longer for the first transaction after power up or when spooling buffered data to the server.
- Status Light: This green light will flash only if a Weather Underground account has been created meaning your data is sending to the site. Refer to Section 2.1 for details on creating an account.
2.3) Registering Your Device
Register your device: To get the most out of your IP-100, you will need to
register it. This will give you your own web page and the ability to edit
settings.
- Visit http://www.rainwise.net/.
- Register on the home page.
- Follow the on screen instructions. You will need your serial number and MAC address located on the bottom of the IP-100. Do not include the dashes between numbers in the MAC address.
The Mac Address and Serial Number contains zeroes; not the letter “O”.
RainWiseNet registration help is located by clicking on the green question
marks. Your information can be edited after registration under the settings
tab of your weather page.
Once you have completed the registration you should now be able to see your
weather webpage. You will receive notices via email as we update our webpage
and add features.
2.4) RainwiseNet Settings From the settings page you may change
your URL address, upload rate, and other options.
You may also add sensors and parameters depending on your model weather
station. It is recommended to only select the sensors that are on your
particular weather station in order to receive accurate data. Be sure to
select “save changes” before returning to your weather dashboard.
3rd party Data Services
The IP-100 can be configured to send data to multiple 3 party services. As we
evolve our registration process we hope to have check off boxes of the desired
3 rd party services you would like to host your data to in order to save time.
3.1)
Weather Underground
Weather Underground is one of the portals where people around the globe share
and see weather data. To send data from your IP-100, click on the “Settings”
tab in RainwiseNet and scroll down. A link is provided here to register an
account. Once you have your station ID and
password, enter the information. Select your desired upload rate and save the
settings.
Within a few minutes your data should begin to appear on your Weather
Underground page. The green status light on the IP-100 will flash with every
data transmission.
3.2) Additional Services
Other portals and websites are available for sharing your weather data. As we
evolve, this list of available portals will change and grow.
Network Settings
By default the IP-100 uses a DHCP server to assign your IP-100 with an
address. This address is for your computer to receive data from your device
wirelessly.
For most users DHCP will assign your computer an address without any issues.
Data is sent to RainwiseNet where it can be viewed.
Refer to Section 4.3 if you desire to manually set a static IP address.
4.1) Minimum Network Requirements
The IP-100 requires a 10/100Base-T Ethernet port for connecting to the
Internet. The IP-100 can be used on a local network.
It is required that the IP-100 have access to the Internet. This ensures
easier configuration and allows for remote firmware updates.
4.2) Ports and Firewall Settings
The IP-100 communicates using port 80. All Internet connections are initiated
by the IP-100 and standard HTTP requests. In most cases no firewall changes
are required. The IP-100 initiates requests on its own. This eliminates the
need to open ports in the firewall.
The embedded web server uses Port 80 and responds to standard HTTP requests.
4.3) Setting a Static IP
To manually set network settings, refer to Section 5.3 (ADMIN).
Internal Web Page
An internal web page exists for your IP-100. You may only access this when you
are on the same network as your device.
This webpage is a direct access route to the data your IP-100 is transmitting.
No internet connection of your IP-100 is needed for this. You can also check
your internal web page if RainwiseNet isn’t updating to see if your device is
working.
From your dashboard click on “Settings”
5.1) Current Weather
Here you can see current weather updates every 15 seconds that your IP-100 is
sending.
5.2) Network
In the network tab of your internal webpage you can view the network settings
of your IP-100.
You will also see the current firmware version your device has.
Transmission stats of your data can also be found here. RainwiseNet stats
along with any other portal you sign up for will display on this page. Should
you need assistance from RainWise Service, they may ask for some of these
stats.
5.3) Admin
To access the ADMIN tab, enter the following username and password.
Username: admin
Password: adminYou may now manually change the settings. When
you are done changing settings, be sure to select Save Network Changes.
If you wish to go back to factory settings you may reset your IP-100. Refer to
Section 6.1 for details.
Troubleshooting
A few troubleshooting steps can be taken if you’re having issues with your
IP-100. If you are having trouble viewing your data on your weather webpage,
refer to section 5.0 to access the internal web page.
6.1) Resetting Your IP-100
- Unplug and re-boot your device.
- Plug your device back in to the power source while pressing and holding the reset button.
- The three main lights on the right will light. Continue holding the reset button until these lights go out (approximately 10 seconds) then release the button. Do NOT unplug for at least 10 minutes.
This procedure clears the password and static settings reinitializing the DHCP.
6.2) Product Support
Product support can be found on Rainwise.com at the bottom of your products
web page.
Documents are available here along with frequently asked questions. If your
support inquiry is not resolved by troubleshooting or our product support, you
may wish to contact Rainwise.
6.3) Contact Information
RainWise Inc.
23 Creek Circle, Boothwyn, PA 19061 USA
Phone: 207-288-5169
Toll Free: 800-762-5723
Online: http://www.rainwise.com/
Contact Form: http://www.rainwise.com/about/contact
Warranty
RainWise, Inc. warrants RainWise, Inc. manufactured IP-100 products against
defects in materials and/or workmanship for a period of 2 years from the date
of purchase and agrees to repair or replace any defective product without
charge. Equipment supplied by RainWise but not manufactured by RainWise is
covered by the particular warranty of that manufacturer.
IMPORTANT: This warranty does not cover damages resulting from accident,
misuse or abuse, lack of reasonable care, the fixing of any attachment not
provided with the product or damage due to a lightning strike. RainWise, Inc.
will not reimburse for take-down or installation charges. RainWise, Inc. will
not pay for warranty service performed by a non-authorized repair service and
will not reimburse the consumer for damage resulting from warranty service
performed by a non-authorized repair service. No responsibility is assumed for
any special, incidental or consequential damages. To return a unit under this
warranty, call (800)762-5723 within the continental US or (207)2885169. The
service department will document the need for repair/replacement and arrange
such. Shipping costs from the customer to RainWise are borne by the customer,
RainWise will cover return shipment. It is the customer’s responsibility to
see that the unit is properly packed, preferably in the original box, because
damage occurring during return shipment is not covered by this warranty.
NOTE: No other warranty, written or oral, is authorized by RainWise, Inc.
This warranty gives you specific legal rights, and you may also have other
rights, which vary from state to state. Some states do not allow the exclusion
of limitation of incidental or consequential damages, so the above exclusion
and limitations may not apply to you.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>