FIBARO FGBS-222 Adapter euFIX SI Instruction Manual

June 12, 2024
FIBARO

FIBARO FGBS-222 Adapter euFIX SI

Product Information

  • Product Name: euFIX SI Adapter
  • Technical Data:
    • Supply voltage: Not specified
    • Load power: Not specified
    • Maximum voltage at the output contacts: Not specified
    • Dimensions: 34.8 x 87.3 x 64.7 mm
    • Width in TE units: 2 TE modules max.
    • Conductor wires cross-section: 1.5 mm2
    • Maximum length of wires connected to In, SD, and SP inputs: 10 m (construction limit of the FIBARO module)
    • Operating temperature: Not specified
    • Relative humidity: Not specified
  • Compliance with EU Directives:
    • LVD 2014/35/EC
    • RoHS 2011/65/EU
  • Package Contents:
    • The suffix Adapter
    • Operating instructions
  • Considerations and Cautions:
    • The installation site should be an electrical switchboard or any distribution box equipped with a DIN (TH35) rail.
    • The adapter is intended for use in locations where the light or other control circuits coincide in the switchgear and not in the flush-mounted boxes behind the wall switches.
    • The adapter should be properly oriented in the switchgear for easy reading of descriptions on the adapter label.

Product Usage Instructions

  1. Installation of the Adapter:
    • Choose an appropriate location in the switchboard or distribution box equipped with a DIN (TH35) rail.
    • Ensure the adapter is properly oriented for easy reading of descriptions on the adapter label.
    • If necessary, mark the module according to your building’s installation design on the white box provided on the adapter label.
    • To remove the adapter from the DIN TH35, pry the latch at the bottom of the adapter casing using a thin, flat screwdriver.
  2. Cable Connections:
    • Important: Only a qualified person with an electrical works license should connect the installed device to the power\ mains.
    • Before starting any installation works, ensure that the mains power supply is disconnected at the distribution board using a B10 overcurrent circuit breaker dedicated for the equipment.
    • If there are reasonable grounds to suspect that the equipment is damaged and cannot be operated safely, do not connect it to the power mains and protect it against accidental powering.
    • When connecting the device to the master function, refer to the manufacturer’s instructions for the respective FIBARO module supplied with this module. Pay particular attention to the warnings and limit values of the module as published in the manual.
  3. Configuration and Commissioning of the Equipment:
    • The S1 and S2 micro-buttons on top of the adapter casing can be used for diagnostics and registering of the FIBARO module with the Z-Wave system.
    • If using the simplified adapter variation without micro-buttons (NP), connect an external button to the screw terminals S1 and S2.

The suffix SI Adapter is used to install the FIBARO® FGBS- 222 Smart Implant module on the DIN TH35 type rail in the electrical switchboard. The suffix SI Adapter consists of the case and the base board, where the FGBS-222 module is mounted. The dimensions of the case are appropriate for a standard DIN TH35 type rail. The base board contains a set of screw terminals, where all the wires (power supply, input and output signals, control pushbuttons) can be safely connected. The front panel of the case contains two diagnostics micro- push-buttons S1 & S2, which can be used to control the module, to register the module within the Z-Wave system or to remove it from the system without opening the adapter’s case. Please note that the FIBARO® FGBS-222 module is not included and needs to be purchased separately.

Technical Data

Supply voltage: 9-30V DC ±10%, 0.5W
Load power: max 150 mA per channel

Maximum voltage at

the output contacts:

| 30V DC / 20V AC ±5%
Dimensions:| 34.8 x 87.3 x 64.7 mm
Width in TE units:| 2 TE modules
Conductor wires cross

section:

| max. 1.5 mm2
Maximum  length  of

wires connected to In, SD and SP inputs:

| 10 m (construction limit of the FIBARO module)
Operating temperature:| 0 °C to +40 °C
Relative humidity:| ≤95 %, no condensation

Compliance with EU Directives

Directives:                             LVD 2014/35/EC

RoHS 2011/65/EU


| Autonomy hereby certifies that the said unit is compliant with essential requirements and is in conformity with other relevant provisions of the above directives. The official Declaration of Conformity  can  be  found  here:

www.eutonomy.com/ce.

| At the end of its useful life this product shall not be disposed with other household or municipal waste. Disposing of this product
****| correctly will help save valuable re- sources and prevent any potential negative effects on human health and the environment, which could otherwise arise from inappropriate

waste handling.

---|---

  • Directives: LVD 2014/35/EC
  • RoHS 2011/65/EU

Package Contents

The package contains the following:

  1.  The suffix Adapter
  2. Operating instructions

If anything is missing, please contact your seller. You can also call or e-mail us at Eutonomy using contact details that can be found here: www.eutonomy.com.
NOTE! The FIBARO® module is not included in the package.

Drawings of kit components

All dimensions are given in millimeters.

Front view of the euFIX Adapter

****| Please read the instructions carefully prior to installation. The instructions contain important guidelines which, when ignored, can lead to danger to life or health. The manufacturer of the equipment is not responsible for any damages resulting from the use of the product in a manner non- compliant with the operating instructions-

tions.

---|---
**| DANGER**

Electrocution risk!

The equipment is intended for oper- ation in the electrical installation. In- correct wiring or use can result in a fire or an electric shock. All instal- lation works can be performed only by a qualified person holding li- censes issued in accordance with

regulations.

**| DANGER**

Electrocution risk!

Before carrying out any rewiring works on the equipment it is manda- tory to disconnect it from the power mains using a disconnector or a cir- cuit breaker in the electrical circuit. The equipment shall be protected by means of an overcurrent circuit breaker with nominal current of 10 A or less and a minimum contact dis-

tance 3 mm.

****| The equipment is intended for in- door use (International Protection Rating IP20).

Side view of the euFIX Adapter

Considerations and Cautions

Place of Installation

The installation site can be an electrical switchboard or any distribution box, equipped with a DIN (TH35) rail. This device is intended for use in all locations where the light or other control circuits coincide in the switchgear and not in the flush-mounted boxes behind the wall switches. Therefore, the wiring should be planned as early as possible, preferably at the stage of the building’s electrical installations and cabling topology design.

Installation of the adapter
To place the FIBARO module in the adapter, remove the top of the adapter casing, gently prying the side latches. The base plate has a 4-pin header bent at an angle of 90°, designed to be screwed into the screw terminals of the Smart Implant Out1 and Out2 outputs. The FIBARO module must be pushed against the pins as far as possible and then tightened with the same force as with normal connecting cables. The pin header ensures almost lossless conduction of current even significantly exceeding the permissible 150mA, provided that it is well adhered to the screw terminals of the FIBARO module. The Smart Implant module must also be connected to the board using the 8-wire cable supplied with the adapter. One of the cores of this cable is the antenna for Z-Wave communication. After making sure that all FIBARO screw terminals are securely tightened to the pin header, the casing can be closed and the module and adapter are ready for installation in the switchgear.

Proper orientation of the adapter in the switchgear should make it easy to read descriptions on the adapter label. The adapter label contains a white box for marking the \module according to your building’s installation design. If you need to take the adapter off the DIN TH35, simply pry a latch at the bottom of the adapter casing with a thin, flat screwdriver.

Cable Connections

**| NOTE!**

The installed device can be con- nected to the power mains only by a person qualified to carry out electrical works, holding licenses issued in accordance with regula-

tions.

---|---


| Before commencing any installa- tion works, please make sure that the mains power supply is discon- nected at the distribution board by means of a B10 overcurrent cir- cuit breaker dedicated for the

equipment.

****| If there are reasonable grounds to suspect that the equipment is damaged and cannot be operated safely, do not connect it to the power  mains and  protect  it

against accidental powering.

When connecting the device to the master function, the manufacturer’s instructions for the respective FIBARO module supplied with this module are fully developed. Particular attention should be paid to the warnings and limit values of the module as published in the manual. The connections diagram of the adapter is shown below terminal descriptions are printed on the adapter label. The description “+” means the positive power input of the Smart Implant module, and “GND” means the ground of the power supply and signal inputs “In1” and “In2”. The adapter has duplicated GND ground inputs, thanks to which there is no need to connect several input wires to one screw terminal, which could deteriorate the reliability of the installation. The relay outputs “Out1” and “Out2” can be connected to devices controlled by the Smart Implant module. The “SP”, “SD” and “GND” outputs can be used to connect sensors compatible with Smart Implant, e.g. DS18B20 temperature sensors. Configuration and Commissioning of the Equipment The S1 and S2 micro-buttons on top of the adapter casing can be used for diagnostics and registering of the FIBARO module with the Z-Wave system. In the case of the simplified adapter variation without micro-buttons (NP), connect an external button to the screw terminals S1 and S2. The detailed procedure is published in the FIBARO module manual.

Maintenance of the Equipment

The adapter can be wiped off with a cloth without the use of aggressive detergents. Do not use a wet cloth to clean the appliance. The adapter does not require any additional maintenance Over time; it is only possible to check the correctness of the tightening of the connecting wires during routine switchboard inspections. Do not carry out any repairs inside the unit. All repairs shall be performed by a specialist service indicated by the manufacturer. Improperly performed repairs may endanger the safety of users.

Service
In case of erratic device operation, we kindly ask you to inform the manufacturer either via an authorized seller or directly by using e-mail addresses and telephone numbers available on our website www.eutonomy.com. Apart from the description of the problem please specify the adapter type. Our Service Department will do their best to solve the problem or your device will be admitted for guarantee or post-guarantee repair.

Guarantee Terms and Conditions

FIBARO-FGBS-222-Adapter-euFIX-SI-fig- \(13\)

GENERAL PROVISIONS

  1. The device is covered with a guarantee. Terms and conditions of the guarantee are outlined in this guarantee statement.

  2. The guarantor of the Equipment is Eutonomy Sp. z o.o. Sp. Komandytowa entered into the Register of Entrepreneurs of the National Court Register kept by the District  Commercial Division of the National Court Register, under no. 0000614778, Tax ID No PL7252129926.

  3. The guarantee is valid for a period of 12 months from the date the Equipment was purchased and covers the territory of EU and EFTA countries.

  4. This guarantee shall not exclude, limit, or suspend the Customer rights resulting from the warranty for defects of the purchased goods.
    OBLIGATIONS OF THE GUARANTOR

  5. During the guarantee period, the Guarantor is liable for defective operation of the Equipment resulting from physical defects thereof disclosed during the guarantee period.

  6. The Guarantor’s liability during the guarantee period includes the obligation to eliminate any disclosed defects\ free of charge (repair) or supply the Customer with Equipment that is free of defects (replacement). Whichever of the above is chosen remains at the sole Guarantor’s discretion. If repair is not possible, the Guarantor reserves the right to replace the Equipment with a new or regenerated Equipment with parameters identical to a brand-new device.

  7. If repair or replacement with the same type of Equipment is not possible, the Guarantor can replace the Equipment with another one bearing identical or higher technical parameters.

  8. The Guarantor does not reimburse the cost of purchasing the Equipment.
    LODGING AND PROCESSING COMPLAINTS

  9. All complaints shall be lodged by telephone or via email. We recommend using the telephone or online technical support provided by the Guarantor prior to entering a guarantee claim.

  10. The proof of purchase of the Equipment is a basis for any claims. After entering a claim via telephone or e-mail the Customer will be notified of what reference number has been assigned to the claim.

  11.  In case of correctly entered complaints a representative of the Guarantor will get in touch with the Customer in order to discuss the details of delivering the Equipment to the service.

  12. The Equipment the Customer is complaining about shall be made accessible by the Customer complete with all components and the proof of purchase.

  13.  In case of unjustified complaints, the costs of delivery and receipt of the Equipment from the Guarantor shall be borne by the Customer.

  14.  The Guarantor can refuse to accept a complaint in the following cases:

    • In case of incorrect installation, improper or unintended use of the Equipment;
    • If the Equipment made accessible by the Customer is not complete;
    • If it is disclosed that a defect had been caused not by a material or manufacturing defect;
    • If the proof of purchase is missing.
      GUARANTEE REPAIR
  15. Subject to Clause 6, defects disclosed during the guarantee period will be eliminated within 30 working days of the date of delivering the Equipment to the Guarantor. In exceptional cases, e.g. missing spare parts or other technical obstacles, the period for performing a guaranteed repair can be extended. The Guarantor will notify the Customer about any such situations. The guarantee period is extended by the time during which the Customer cannot use the Equipment due to its defects.
    EXCLUSION OF GUARANTOR’S LIABILITY

  16.  The Guarantor’s liability stemming from the granted guarantee is limited to the obligations specified in this guarantee statement. The Guarantor will not be liable for any damages caused by defective operation of the Equipment. The Guarantor shall not be liable for any indirect, incidental, special, consequential, or punitive damages, or for any other damages, including but not limited to loss of profits, savings, data, loss of benefits, claims by third parties, and any property damage or personal injuries arising from or related to the use of the Equipment. 18. The guarantee shall not cover natural wear and tear of the Equipment and its components as well as the product defects not arising from reasons inherent in the product caused by improper installation or use of the product contrary to its intended purpose and instructions for use.

    •   * In particular, the guarantee shall not cover the following:
    • Mechanical damages caused by impact or fall of the Equipment;
    • Damages resulting from Force Majeure or external causes – also damages caused by malfunctioning or malicious software running on the installer’s computer hardware;
    • Damages resulting from the operation of the Equipment in conditions different than recommended in the instructions for use;
    • Damages caused by incorrect or faulty electrical installation (not consistent with the instructions for use) in the place of Equipment operation;
    • Damages resulting from carrying out repairs or introducing modifications by unauthorized persons.
    • If a defect is not covered by the guarantee, the Guarantor reserves the right to carry out repair at its sole discretion by replacement of damaged components.
    • Postguarantee servicing is provided against payment.

Trademarks

All FIBARO names referred to in this document are registered trademarks belonging to Fibar Group S.A.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

FIBARO User Manuals

Related Manuals