BritTherm 636199 Domestic Standard Instruction Manual

June 12, 2024
BritTherm

Installation & Operating Instructions

Please read these instructions carefully before installation

General Information

These instructions guide you through the installation and operation of this BritTherm™ Circulator. The Bronze E:n is a Secondary Hot Water Circulator which is perfectly suited to operate in:

  • Single zone Hot Water systems
  • Multi zone Hot Water systems

The Pump incorporates 3 constant speeds enabling you to set it based on system demand. It has a connection size of 1 /2, a maximum head of 6 metres and a port to port distance of 130mm making it perfect for domestic applications. This circulator is suitable for drinking water only The benchmark for the most efficient circulators is EEl <020

Pump Liquid & Operating Conditions

BritTherm™ pumps require clean, thin, non-aggressive liquids to operate correctly and prevent damage to their internal components. The liquids used must not contain any solid particles, fibres or mineral oil.
Liquids running through circulation pumps must comply with the accepted standards of quality especially in domestic applications. Liquids that do not comply will void the warranty offered with this Pump.

Pump Diagram

Installation

Attention: Ensure the pump is installed with the Control Box on the left

Attention: Fit the two gaskets when the pump is mounted correctly between the flow and return pipes

Fault Finding

Before starting any work on the pump please ensure the electricity supply is turned off and cannot be accidentally switched back on at any time
Fault
Pump doesn’t run

Cause Remed
A) Blown fuse Replace fuse
B) Inadequately connected power supply Check electrical connection
C) Pump is defective Replace pump
D) Impurity in the system Disconnect and clean
E) Bearing has blocked pump from running Run at high speed for a for a short

period or loosen the rotor at the end of the shaft with a screwdriver

Noise in the system

Cause Remedy
A) Air in the system Vent the system
B) Pump speed too high Reduce the speed

Fault
Noise in the pump

Cause Remedy
A) Air in the pump Let the pump run, it vents itself over time
B) Inlet pressure too low Increase the inlet pressure

Maintenance & Repair

Attention: Ensure the pump is fully vented before first time operation

Attention: The pump liquid may be scalding hot and under high pressure. Before removing head screws the system either requires draining, or the pump needs to be isolated

Guarantee Registration

This Pump is covered against manufacturing malfunction by a 3 year guarantee. The guarantee is only valid if the pump has been installed correctly, the system is maintained adequately, and the guarantee is registered within 30 days of purchase.
The pump is covered for a free of charge replacement should malfunction occur within the first 3 years from the date of sale.
To register go to www.BritTherm.co.uk and click
Register a Guarantee
You will need:

  • Date of purchase
  • Address where pump is fitted
  • Name of supplier
  • Supplier invoice number
    Please retain your purchase invoice as it may be required in the event of a guarantee claim.
    To make a claim please contact BritTherm by email in the first instance: info@BritTherm.co.uk

Documents / Resources

| BritTherm 636199 Domestic Standard [pdf] Instruction Manual
636199 Domestic Standard, 636199, Domestic Standard
---|---
| BritTherm 636199 Domestic Standard [pdf] Instruction Manual
636199 Domestic Standard, 636199, Domestic Standard

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals