BRITTHERM BLB15 Black Booster Semi Automatic Domestic Mains Water Home Booster Instruction Manual

June 13, 2024
BritTherm

BRITTHERM logo

Installation & Operating Instructions

BRITTHERM BLB15 Black Booster Semi Automatic Domestic Mains Water Home
Booster

Please read these instructions carefully before installation

General Information

These instructions will guide you through the installation and operation of the Brit Therm™ Booster Range.
3 Mode Semi-Automatic Mains Water Home Booster come in two models:
o Black Booster 15-90/160 (BLB15) – Epoxy Coated Cast Iron
o Silver Booster 15-90/160 (SBS15) – Stainless Steel

Domestic Mains Water Home Booster comes with a standard ¾” threaded connection. It has a port to a port distance of 160mm and produces a maximum head of 9 meters, making it perfect for boosting mains pressure to the optimum level. Max Flow Rate is
23 litres per minute with Max System Pressure of 6 Bar.
It is by far the UK’s best Home Booster in terms of value for money and it is uniquely easy to use and install. The Black Booster comes with a 3 year Brit Therm™ guarantee and is no different in size to the market leading brands found in most British homes.

Pump Liquid & Operating Conditions

Brit Therm™ pumps require clean, thin, non-aggressive liquids to operate correctly and prevent damage to their internal components. The liquids used must not contain any solid praticles, fibres or mineral oil.
Liquids running through circulation pumps used on heating systems must comply with the accepted standards of quality especially in domestic applications.
Liquids that do not comply will void the warranty offered with the circulation pump.

Pump Diagram

BRITTHERM BLB15 Black Booster Semi Automatic Domestic Mains Water Home
Booster - Fig 1

Installation and Attention

  • Before the installation, please make sure all pipe system is well connected, and free of inclusions, welding spatter and dirt; electrical frequency 50Hz, voltage single phase 220V, voltage fluctuation between -10% – +6%.
  • The pump should be installed in dry and ventilated place, in case any short circuit caused by moisture or water splash, and easy for maintenance and replacement afterwards.
  • Protection cover required if installed in open air; if installed indoors, prevent from water splash in case any electric shock occurs, do not install in the bathroom, in case the vapour goes into the connection box and cause the leakage.
  • After installation, connect the power and test run, switch to automatic mode and check up the starting.
  • For convenience of maintenance, it is recommended to install independent shutoff valves at the inlet and outlet place.
  • If long time no use, please shut off the inlet valve and cut off the electricity.
  • Make sure the socket is grounding, and connect the grounder of the plug and the socket. Do not modify the grounding of the pump without approval.
  • Use visible safety warning signs at the site in case any accident happens while the pump is working.
  • Shut off the power if any adjustment of the location or any contact to the pump while the pump is working.
  • Schedule inspection required, replace in time if there is any part out of order.
  • Inspect the insulation resistance of the pump regularly, and make sure the cold state insulation resistance is no less than 50MQ.
  • Use the proper cable or buy the proper assembly to replace if there is any cable break down.
  • When the temperature is below 0°C, please discharge all the water from the pipe to avoid frost crack of the pump body if the pump is not in use.
  • The pump could be stopped automatically because of the water quality (like water incrustation, inclusion) or other causes. Please check up the motor and make sure it is not hot.
  • Do not install the faucet at the pump suction side, or it may cause water backflow or air inflow into the pipe work, that are bad for pump performance.
  • Do not install the pump at the boiler discharging side. Hot water is bad for booster pump life.
  • Keep the inlet pressure higher than 0.01MPa but lower than 0.6MPa.

Pump Installation

Keep the motor shaft horizontally during installation; the flow direction should follow the arrow directi on marked on the pump body.

BRITTHERM BLB15 Black Booster Semi Automatic Domestic Mains Water Home
Booster - Fig 2

The top discharging point (tap or shower head) must be at least | meter below the water level in the tank.BRITTHERM BLB15 Black Booster Semi Automatic
Domestic Mains Water Home Booster - Fig 3

Discharge the Air Before Installation

Discharge the air properly to make sure the pumps working best after installation or maintenance. Do not let the water get into the connection box or the socket in case any electrical failure caused.

BRITTHERM BLB15 Black Booster Semi Automatic Domestic Mains Water Home
Booster - Fig 4

Guarantee Registration

This Pump is covered against manufacturing malfunction by a 3 year guarantee. The guarantee is only valid if the pump has been installed correctly, the system is maintained adequately, and the guarantee is registered within 30 days of purchase.
The pump is covered for a free of charge replacement should malfunction occur within the first 3 years from the date of sale.

To register go to www.BritTherm.co.uk  and click Register a Guarantee

You will need:

Date of purchase
Address where pump is fitted
Name of supplier
Supplier invoice number

Please retain your purchase invoice as it may be required in the event of a guarantee claim.
To make a claim please contact Brit Therm by email in the first instance: info@BritTherm.co.uk

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals