STAHL 8579A Wall Mount Socket

Installation Equipment

Wall-mounting socket 63 A
8579/31-407 Art. No. 270906

  • Reliable load disconnect switch with easily visible, lockable handle and switching position display
  • An integrated auxiliary contact for control and signalling purposes, can optionally be enhanced with pluggable, easily retrofittable Ex e or Ex i auxiliary contacts
  • Wide temperature range for use
  • High mechanical impact and shock resistance
  • Perfect protection against the ingress of liquids and dust
  • 3D data available to download from the website

WebCode 8579A

R. STAHL Series 8579/ 31 sockets for Zone 1/ 21 in a 4- and 5- pole version have full AC- 3 switching capacity up to 63 A. The high degree of protection IP66 guarantees the highest level of protec-tion against the penetration of dust and water in any application position. Self- cleaning lamellar contacts provide optimum contact and the plugs can be inserted and removed in the zero position quickly and easily. The load disconnect switch, with mechanical locking device and a handle that can be locked in the 0 or I position, is an additional safety feature.

Technical Data

Explosion Protection

Scope of validity| European Union (ATEX) IECEx

China (CQST)

Application range (zones)| 1

2

21

22

IECEX gas certificate| IECEx PTB 06.0020
IECEx gas explosion protection| Ex db eb IIC T6 … T5 Gb
IECEX dust certificate| IECEx PTB 06.0020
IECEx dust explosion protection| Ex tb IIIC T60 °C / T75 °C Db
ATEX gas certificate| PTB 01 ATEX 1150
ATEX gas explosion protection| E II 2 G Ex db eb IIC T6 … T5 Gb
ATEX dust certificate| PTB 01 ATEX 1150
ATEX dust explosion protection| E II 2 D Ex tb IIIC T60 °C / T75 °C Db
Certificates| ATEX (PTB), Brazil (ULB), China (CQST), EAC (ENDCE), IECEx (PTB), Korea (KGS),

Taiwan (ITRI)

Explosion protection note| Product label may vary. Series devices have certification according to ATEX and IECEx.
Electrical Data
Rated operational voltage AC| 480 to 500 V AC
Rated operational current| max. 63 A
Electrical service life| > 2×104 switching cycles
Mechanical service life| > 2×104 switching cycles
Type of voltage| Low voltage
Electrical Data

Switching capacity main contacts| AC-3

690 V, 63 A

18.5 kW: 220 / 230 / 240 V

30 kW: 380 / 400 / 415 V

37 kW: 500 V

55 kW: 690 V

Auxiliary contacts| 2 (1 NO + 1 NC)
Frequency range| 50 / 60 Hz
Device Specific Data
Back-up fuse with thermal protection| 80 A gG
Back-up fuse without thermal protection| 63 A gG
Ambient Conditions
Ambient temperature| -45 °C … +40 °C (T6)

-45 °C … +55 °C (T5)

Ambient temperature| -49 °F … +104 °F (T60 °C)

-49 °F … +131 °F (T75 °C)

Mechanical Data
IP degree of protection (IEC 60529)| IP66
IP degree of protection (IEC 60079)| IP66
Enclosure material| Polyester, Glass fibre reinforced
Silicone-free| No
Multiple conductor connection| 2 x 16 mm²
Finely stranded connection cross-section| 1 x 16 mm² … 1 x 50 mm²
Connection cross-section AWG finely

stranded

| 1 x AWG 6 … 1 x AWG 1/0
Width| 180 mm
Width in inches| 7.09 in
Height| 212 mm
Height, inches| 8.36 in
Length| 413 mm
Length, inches| 16.27 in
Impact strength (IEC 60079)| 7 J
Impact strength (IEC 62262)| IK10
Colour code| Black
Coding (clock hour position)| 7
Lockable in| in 0- and I-position
Series| SolConeX
Detailed number of poles| 3 P + PE
Weight| 7.8 kg
Weight| 17.2 lb
Mounting / Installation
Connection| Screw terminal
Components
Cable entry note| Entry 1: Lower left

Entry 2: Lower right

Entry 1 model| 8161/7-M50-3516-LT
Components

Entry 1 type| Polyamide cable gland
Entry 1| M50 x 1.5
Entry 1 terminal area| 16 – 35 mm
Entry 1 clamping range, inch| 0.63 – 1.38 in
Metal entry possible 1| No
Entry 2 model| 8290/3-M25
Entry 2 type| Polyamide stopping plug
Entry 2| M25 x 1.5
Metal entry possible 2| No

Technical Drawings – Subject to Alterations

Position of clock hour position
Example: 6 h position

Dimensional Drawings (All Dimensions in mm [inches]) – Subject to Alterations

STAHL 8579 A Wall Mount Socket-2

Wall-mounting socket

Accessories

 |  |
---|---|---
****| 2 NC contacts (8080/1-3)| 168356
250 V AC/DC|
max. 6 A|
1.5….. 2.5 mm² solid / finely stranded|
The switching function of the auxiliary contact depends on the installation slot used.|
Left and right: synchronising|
1 NC contact + 1 NO contact (8080/1-1)| 168351
250 V AC/DC|
max. 6 A|
1.5….. 2.5 mm² solid / finely stranded|
The switching function of the auxiliary contact depends on the installation slot used.|
Left: delayed (ON), leading (OFF)|
Right: synchronising|
2 NO contacts (8080/1-4)| 168353
250 V AC/DC|
max. 6 A|
1.5….. 2.5 mm² solid / finely stranded|
The switching function of the auxiliary contact depends on the installation slot used.|
Left and right: synchronising|

Auxiliary contact key

****| for removing the mounted auxiliary contact| 201909
---|---|---

Cable gland made of plastic

****| 8161/7-M25-1707, Ex e

Plastic, M25 x 1.5, cable outer diameter 7 to 17 mm Lot size 50 pieces

| 239157
---|---|---
8161/7-M50-3516, Ex e

Plastic, M50 x 1.5, cable outer diameter 16 to 35 mm Batch size 4 pieces

| 239160

Ex i cover

****| Ex i cover for auxiliary contacts for use in Ex i circuits| 168855
---|---|---

Stopping plug

****| 8290/3-M25

Plastic, M25 x 1.5 Lot size 1 piece

| 143524
---|---|---

Switch insert

**** 8544/1-31L 167239

Spare Parts

Repair kit for sockets 63 A Series 8579 Art. No.
**** Repair kit 8579 hinged cover, black

275509

We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding.

R. STAHL Schaltgeräte GmbH | Am Bahnhof 30 | 74638 WALDENBURG
Tel. +49 7942 943 1700 | +49 7942 943 1777 | Email: sales.de@r-stahl.com | r-stahl.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals