ASW5000-S-A Single Phase Inverters Instruction Manual
- June 4, 2024
- ASW
Table of Contents
ASW S Series
Single-phase inverters 5 to 10 kW
Models:
ASW5000-S-A ASW6000-S-A ASW8000-S-A ASW10000-S-A
ASW5000-S-A Single Phase Inverters
Easy-to-install
- Toolless DC connection via Phoenix Contact connectors
- Quick setup and commissioning with AiSWEI apps
- Compact wall mount design
Reliable
- International quality standards
- Integrated DC switch
- IP66 rated design for outdoor use
User-friendly
- 16 A input current, compatible with bifacial and large-area PV modules
- Online monitoring via Wi-Fi and AiSWEI apps
- 3 MPPT´s for flexible PV array design
Technical Datasheet
ASW5000-S-A ASW6000-S-A ASW8000-S-A ASW10000-S-A
Input (DC)| Max. PV array power| 8000 Wp STC| 9000 Wp STC| 12000 Wp STC| 15000
Wp STC
---|---|---|---|---|---
Max. input voltage| 600 V
MPP voltage range / rated input voltage| 80 V – 560 V / 360 V
Min. input voltage| 80 V
Initial. feed in voltage| 100 V
Max. operating input current| 16 A
Max. short circuit current| 22.5 A
No. of independent MPPT inputs/strings per MPPT input| 3 / 1
Output (AC)| Rated active power| 5000 W| 6000 W| 8000 W| 10000 W
Rated apparent Power| 5000 VA| 6000 VA| 8000 VA| 10000 VA
Max. apparent power| 5000 VA| 6600 VA| 8800 VA| 10000 VA
AC nominal voltage| 220 V / 230 V / 240 V
AC voltage range| 180 V to 295 V
AC grid frequency / range| 50 Hz / 45 Hz to 55 Hz 60 Hz / 55 Hz to 65 Hz
Max. output current| 21.7A| 30 A| 40 A| 50 A
Adjustable power factor range| 0.8 leading to 0.8 lagging
Feed-in phases| 1
Harmonic distortion (THD) at rated output| < 3 %
Efficiency & Protection| Max. efficiency / European efficiency| 97.7 % / 97.3
%
DC switch| ●
Ground fault monitoring/grid monitoring| ● / ●
DC reverse polarity protection / AC short circuit protection| ● / ●
The all-pole-sensitive residual-current monitoring unit| ●
Protection class (according to IEC 62109-1) / overvoltage category (according
to IEC 62109-1)| I/AC: III; DC :ll
General data| Dimensions (W / H / D)| 503 / 435 / 183 mm
Weight| < 18 kg
Operating temperature range| -25°C … +60°C
Self-consumption (at night)| < 1 W
Topology| Non-isolated
Cooling concept| Natural convection
Degree of protection (according to IEC 60529)| IP66
Climatic category (according to IEC 60721-3-4)| 4K4H
Max. permissible value for relative humidity (non-condensing)| 100%
Max. operating altitude| 3000 m
Features| DC connection| Plug-inconnector
AC connection| Plug-in connector
Mounting type| Wall-mount bracket
LED indicators (Status / Fault / Communication)|
●
Communication interface1&2| Wi-Fi / 4G / RS485 (Optional)
Country of Manufacture| China
Certificates and approvals (more available on request)| CE, EN50549, IEC62109,
IEC62116, IEC61727, IEC61683, IEC60068, IEC61000, AS/NZS4777, C10/C11
- Standard features / ○ optional features / – not available
Data at nominal conditions. All information is subject to change.
1- Zero export installations supported with 2-pin RS485 for connection to approved smart meters
2- DRED supported with RS485 communication for Australia & New Zealand
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>