HYSUN W2 Wallbox EV Charger User Manual

June 12, 2024
HYSUN

W2 Wallbox EV Charger
User ManualHYSUN W2 Wallbox EV Charger Wallbox EV Charger
W2 User Manual

Product Overview

HYSUN W2 Wallbox EV Charger - Overview Installation Kits Tool

HYSUN W2 Wallbox EV Charger - Installation Kits Tool

Technical specifications

General

Dimensions| 200mm x 200mm x 65mm (LWH)
Wall mounting Operation Temperature| 40°C—+55°C
Weight| 4KG
Charging
Charging power| 7kW
Charging Plug| GBT (GB/T 20234.3-2015)
Power Supply| 1phase (7kW)
Voltage| 230Vac (-±10 %)
Mains frequency| 50/60 Hz
Connectivity
Built-in eSIM
WiFi 2.4Ghz connection
Control charging via X smart App
RFID reader
OCPP 1.6
Dynamic Load Balancing CT
MID meters

Protection

  • Integrated protection for open / break fault condition in supply PEN conductor according to BS 7671:2018/A1:2020
  • Built-in RCD for ground fault protection (30 mA AC/ 6 mA DC) according to EN 61008-1 and IEC 62955
Degree of protection IP65
Impact resistance IK10
Insulation class I
Overvoltage category III

Dimension & Package

Control Box Size: L200 x W200 x H65mm
Cable Length: 4.5Meter / Customized
Inner Box: L300 x W300 x H150mm
Outer Carton: L340 x W340 x H330mm

Important Safety Instructions

  1. Ensure that the equipment is well grounded before powering it on.
  2. Keep the charging gun head clean and dry. If it gets dirty, wipe it with a clean and dry cloth.
  3. Do not touch the charging gun with your hands while charging.
  4. Make sure that the input voltage, frequency, circuit breaker, or fuse of the device and other conditions meet the specifications before powering on the equipment.
  5. Insulate all tools as necessary to prevent bare metal parts from touching the metal frame and causing a short circuit.
  6. Do not attempt to disassemble, repair or modify the charging pile. If maintenance or modification is necessary, contact the staff. Improper operation can result in equipment damage, water leakage, leakage, and other hazards. This equipment should be installed, adjusted, and serviced by qualified electrical personnel familiar with the construction and operation of this type of equipment and the hazards involved.
  7. The equipment should be operated in a clean, constant temperature, and constant humidity environment as much as possible, and the operating environment must not contain volatile gases or flammable gases.
  8. Charge with caution during rain and thunder.
  9. Follow the instructions strictly during use. Do not allow children to get close to or use the charging pile while charging to avoid injury.
  10. After charging is complete, hang the charging gun properly back into the charging gun base. Avoid placing the charging gun head at random or dropping it on the ground to prevent safety accidents.

Installation instructions

WARNING: Turn off the power before you begin the Installation. Use extrem caution and follow Instructions carefully.
1.Drilling

  1. Use the BIGGER plate to mark the location of the screw holes on the wall where you plan to mount the station.
  2. Use a drillto make holes in the wall where you marked the locations.
  3. Hammer the plastic bolts into the holes you drilled.

2.Mounting

  1. Fix the BIGGER plate to the wall using screws.
  2. Hang the WALLBOX station on the plate that is now affixed to the wall.
  3. Lock the bottom anti-sheft  SMALLER plate with screws.HYSUN W2 Wallbox EV Charger - Mounting 3
  4. Hang the WALLBOX station on the plate that is now affixed to the wall.HYSUN W2 Wallbox EV Charger - Mounting 5

Features

HYSUN W2 Wallbox EV Charger - Features

Charging interface

Working State Red Green Blue
PowerOn (Unplugged) / Stays On /
Insert the plug (Uncharged) / / Stays On
Charging Mode / / Flashihg
Charging Completed / / Stays On
Metering communication error Stays On / /
Under-voltage alarm Stays On / /
Over-voltage alarm Stays On / /
Groundfault Stays On / /
Over current protection Stays On / /
Leakage protection Stays On / /
Overtemperature protection Stays On / /
RFID failure Stays On / /
Relay failure Stays On / /
Memory failure Stays On / /

Remarks:Fault reason will display on LCD screen when RED indicator stays on.

Customer Support
For Technical Assistance Call:
T: 0086-180-254-31819
E: [email protected]
For additional products and information,
please visit our website at: www.hysunpower.com.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>