MITSUBISHI ELECTRIC P-Series Wall Mounted Air Conditioning System User Guide

June 12, 2024
Mitsubishi Electric

MITSUBISHI-ELECTRIC-logo

MITSUBISHI ELECTRIC P-Series Wall Mounted Air Conditioning System

MITSUBISHI-ELECTRIC-P-Series-Wall-Mounted-Air-Conditioning-System-
product

Product Information

  • The P-Series Model Reference Guide provides detailed information about the P-Series lineup of indoor and outdoor units. The P-Series includes six indoor units and three categories of outdoor units, allowing users to build a system that best matches their heating and cooling needs. The units are designed for professional use and offer high energy efficiency, thanks to a newly designed compressor and advanced variable-speed INVERTER-drive technology.
  • The indoor units include wall-mounted, ceiling-suspended, ceiling cassette, and horizontal-ducted options. The outdoor units are available in cooling only, heat pump, and hyper-heating models.
  • The P-Series lineup offers industry-leading energy efficiency and advanced energy-saving technologies.

Product Usage Instructions

To use the P-Series system, follow these steps:

Step 1: Select your Indoor Unit

  1. Choose from the following indoor units:
    • Wall-mounted PKA-HA
    • 4-Way Ceiling Cassette PLA
    • Wall-mounted PKA-KA

Step 2: Select your Outdoor Unit

  1. Choose from the following outdoor unit options:
    • Cooling Only:
    • Ceiling-concealed PEAD
    • Multi-position Air Handler PVA
    • Ceiling-suspended PCA
    • Heat Pump:
    • PUY-A12NKA7
    • PUY-A18NKA7
    • PUY-A24NHA7
    • PUY-A30NHA7
    • PUY-A36NKA7
    • PUY-A42NKA7
    • PUZ-A12NKA7
    • PUZ-A18NKA7
    • PUZ-A24NHA7
    • PUZ-A30NHA7
    • PUZ-A36NKA7
    • PUZ-A42NKA7
    • PUZ-HA24NHA1
    • PUZ-HA30NKA
    • PUZ-HA36NKA
    • PUZ-HA42NKA1

Note : The selection of indoor and outdoor units should be based on the specific heating and cooling requirements of your application.
For further information and details about the P-Series lineup, please refer to the complete user manual.

P-Series Model Reference Guide

MITSUBISHI-ELECTRIC-P-Series-Wall-
Mounted-Air-Conditioning-System-fig- \(1\)

  • Designed for light commercial installations. Ideal for applications requiring year-round, low ambient cooling such as computer, elevator and equipment rooms
  • Hyper-Heating INVERTER® (H2i®) outdoor units can provide superior heating performance at lower ambient temperatures
  • Long lineset lengths
  • Outside air intake on PLA, PCA, PEAD and PVA models
  • P-Series ducted units have higher static than most M-Series, allowing for design flexibility

P-Series Product Lineup

The P-Series lineup includes a selection of six indoor units and three categories of outdoor units. You can easily build a system that best matches the application’s heating and cooling needs.

Step 1: Select your Indoor UnitMITSUBISHI-ELECTRIC-P-Series-Wall-Mounted-
Air-Conditioning-System-fig- \(2\)

Step 2: Select your Outdoor Unit
Choose from Cooling Only, Heat Pump, or Hyper-heating models.

Cooling OnlyMITSUBISHI-ELECTRIC-P-Series-Wall-Mounted-Air-Conditioning-
System-fig- \(3\)

Heat PumpMITSUBISHI-ELECTRIC-P-Series-Wall-Mounted-Air-Conditioning-
System-fig- \(4\)

Hyper-Heating INVERTER® Heat PumpMITSUBISHI-ELECTRIC-P-Series-Wall-
Mounted-Air-Conditioning-System-fig- \(5\)

P-Series
Industry-leading energy efficiency has been achieved by optimizing a newly designed compressor and using the latest energy-saving technologies. All compressors offer high performance due to advanced variable-speed INVERTER- drive technology, which varies the compressor speed dynamically to adapt to the room’s conditioning requirements.

Industry Leading Energy Efficiency

Industry-leading energy efficiency has been achieved through optimization of a newly designed compressor and the use of the latest energy-saving technologies. All compressors offer high performance due to advanced variable- speed INVERTER-drive technology, which varies the compressor speed dynamically to continuously adapt to the conditioning requirements of the room .MITSUBISHI-ELECTRIC-P-Series-Wall-Mounted-Air-Conditioning-System-fig-
\(6\)

Advanced Energy-Saving Technology

Highly efficient fan for outdoor unit Fan opening of 21-3/4” (A36-42)
The opening for the fan in the outdoor unit is 21-3/4” in diameter. Exchanging heat more efficiently contributes to increased energy-savings and lower noise levels.

Highly efficient heat exchanger

High-density heat exchanger (A36-42)
The A36-42 units use a 5/16” diameter pipe. The high-density heat exchanger contributes to efficient heat exchange and reduces the amount of refrigerant used, which benefits the environment.

Improved fan (A36-42)
A newly designed fan increases airflow capacity and reduces operation noise.

PLA Model

MITSUBISHI-ELECTRIC-P-Series-Wall-Mounted-Air-Conditioning-
System-fig- \(10\)

Remote Controller

MITSUBISHI-ELECTRIC-P-Series-Wall-Mounted-Air-
Conditioning-System-fig- \(11\)

Model Selection

Cooling OnlyMITSUBISHI-ELECTRIC-P-Series-Wall-Mounted-Air-Conditioning-
System-fig- \(12\)

Indoor Unit|  |  |  | PLA- A12EA7| PLA- A18EA7| PLA- A24EA7| PLA- A30EA7| PLA- A36EA7| PLA- A42EA7
---|---|---|---|---|---|---|---|---|---
Outdoor Unit|  |  |  | PUY-A12NKA7(- BS)| PUY- A18NKA7(- BS)| PUY-A24NHA7(- BS)| PUY-A30NHA7(- BS)| PUY-A36NKA7(- BS)| PUY-A42NKA7(- BS)

Cooling

| Capacity| Rated 1| BTU/H| 12,000| 18,000| 24,000| 30,000| 36,000| 42,000
Capacity Range| Min-Max| BTU/H| 5,800–12,000| 8,000–18,000| 10,000–24,000| 9,000–30,000| 16,000–36,000| 16,000–42,000
Power Input| Rated 1| W| 730| 1,250| 1,670| 2,540| 2,780| 3,590
Moisture Removal| Pints/h| 1.2| 2.4| 3.0| 5.4| 4.5| 7.9
Sensible Heat Factor| 0.890| 0.850| 0.860| 0.800| 0.860| 0.790

Heating

| Capacity at 47ºF| Rated| BTU/H| —| —| —| —| —| —
Capacity Range| Min-Max| BTU/H| —| —| —| —| —| —
Power Input at 47ºF| Rated| W| —| —| —| —| —| —
Capacity at 17ºF| Rated| BTU/H| —| —| —| —| —| —
Max| BTU/H| —| —| —| —| —| —
Capacity at 5ºF| Max| BTU/H| —| —| —| —| —| —
Capacity at -5ºF| Max| BTU/H| —| —| —| —| —| —

Efficiency

| SEER| 27.0| 24.6| 24.2| 22.8| 21.8| 21.0
EER| 16.4| 14.4| 14.3| 11.8| 12.9| 11.6
HSPF| —| —| —| —| —| —
COP| —| —| —| —| —| —
ENERGY STAR® Certified| Yes| Yes| Yes| No| Yes| No

Indoor Unit

| Air Flow Rate – Cooling (Quiet-Lo-Med-Hi-SHi)| Dry| CFM| 420–460–490–530| 420–460–570–600| 530–640–710–810| 570–670–780–880| 670–850–1020–

1200

| 740–920–1060–

1200

Air Flow Rate – Cooling (Quiet-Lo-Med-Hi-SHi)| Wet| CFM| 380–420–450–490| 380–420–530–560| 490–600–670–770| 530–630–740–840| 630–810–980–1160| 700–880–1020–

1160

Air Flow Rate – Heating (Quiet-Lo-Med-Hi-SHi)| Dry| CFM| 420–460–490–530| 420–460–570–600| 530–640–710–810| 570–670–780–880| 670–850–1020–

1200

| 740–920–1060–

1200

Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)| Cooling| dB(A)| 27–28–29–30| 28–29–31–32| 28–30–33–36| 28–32–35–38| 32–37–41–44| 34–38–42–45
Sound Pressure Level (Quiet- Lo-Med-Hi-SHi)| Heating| dB(A)| 27–28–29–30| 28–29–31–32| 28–30–33–36| 28–32–35–38| 32–37–41–44| 34–38–42–45
External Static Pressure| In. W.G.| —| —| —| —| —| —
Condensate Lift Mechanism| Max Distance| In. [mm]| 33-7/16 [849]| 33-7/16 [849]| 33-7/16 [849]| 33-7/16 [849]| 33-7/16 [849]| 33-7/16 [849]

Dimensions

| H| In. [mm]| 10-5/32 // 1-9/16 [258 // 40]| 10-5/32 // 1-9/16 [258 // 40]| 11-3/4 // 1-9/16 [298

// 40]

| 11-3/4 // 1-9/16 [298

// 40]

| 11-3/4 // 1-9/16 [298

// 40]

| 11-3/4 // 1-9/16 [298

// 40]

W| In. [mm]| 33-1/16 // 37-13/32 [840 // 950]| 33-1/16 // 37-13/32 [840 // 950]| 33-1/16 // 37-13/32 [840 // 950]| 33-1/16 // 37-13/32 [840 // 950]| 33-1/16 // 37-13/32 [840 // 950]| 33-1/16 // 37-13/32 [840 // 950]
D| In. [mm]| 33-1/16 // 37-13/32 [840 // 950]| 33-1/16 // 37-13/32 [840 // 950]| 33-1/16 // 37-13/32 [840 // 950]| 33-1/16 // 37-13/32 [840 // 950]| 33-1/16 // 37-13/32 [840 // 950]| 33-1/16 // 37-13/32 [840 // 950]
Weight| lbs [kg]| 46 // 11 [21 // 5]| 46 // 11 [21 // 5]| 56 // 11 [25 // 5]| 56 // 11 [25 // 5]| 56 // 11 [25 // 5]| 56 // 11 [25 // 5]

Outdoor Unit

| MCA| A| 11.0| 11.0| 19.0| 19.0| 25.0| 25.0
MOCP| A| 28| 28| 26| 26| 31| 31

Dimensions

| H| In. [mm]| 24-13/16 [630]| 24-13/16 [630]| 37-1/8 [943]| 37-1/8 [943]| 52-11/16 [1338]| 52-11/16 [1338]
W| In. [mm]| 31-13/16 (+7/16) [809 (+62)]| 31-13/16 (+7/16) [809 (+62)]| 37-13/32 [950]| 37-13/32 [950]| 41-5/16 [1050]| 41-5/16 [1050]
D| In. [mm]| 11-3/16 [300]| 11-3/16 [300]| 13 (+1-3/16) [330

(+30)]

| 13 (+1-3/16) [330

(+30)]

| 13 (+1-3/16) [330

(+30)]

| 13 (+1-3/16) [330

(+30)]

Weight| lbs [kg]| 92 [41]| 99 [44]| 151 [68]| 151 [68]| 211 [96]| 211 [96]
Air Flow Rate (Cooling/ Heating)| CFM| 1590/—| 1590/—| 1940/—| 1940/—| 3880/—| 3880/—
Sound Pressure Level| Cooling| dB(A)| 44| 44| 47| 47| 52| 52
Heating| dB(A)| —| —| —| —| —| —

Piping

|

Diameter

| Gas (O.D.)| In. [mm]| 1/2 [12.7]| 1/2 [12.7]| 5/8 [15.88]| 5/8 [15.88]| 5/8 [15.88]| 5/8 [15.88]
Liquid (O.D)| In. [mm]| 1/4 [6.35]| 1/4 [6.35]| 3/8 [9.52]| 3/8 [9.52]| 3/8 [9.52]| 3/8 [9.52]
Indoor Drain| In. [mm]| 1-1/4 [32]| 1-1/4 [32]| 1-1/4 [32]| 1-1/4 [32]| 1-1/4 [32]| 1-1/4 [32]
Max. Length| ft [m]| 165 [50]| 165 [50]| 225 [68]| 225 [68]| 225 [68]| 225 [68]
Max. Height| ft [m]| 100 [30]| 100 [30]| 100 [30]| 100 [30]| 100 [30]| 100 [30]
Electrical| Outdoor-Indoor5| V, ph, Hz| 208/230, 1, 60| 208/230, 1, 60| 208/230, 1, 60| 208/230, 1, 60| 208/230, 1, 60| 208/230, 1, 60
Recommended Breaker Size| A| 15| 15| 25| 25| 30| 30
Refrigerant Type| R410A| R410A| R410A| R410A| R410A| R410A
Guaranteed Temperature Operation Range| Cooling6| ºF DB [ºC DB]| -40 to 115 [-40 to 46]| -40 to 115 [-40 to 46]| -40 to 115 [-40 to 46]| -40 to 115 [-40 to 46]| -40 to 115 [-40 to 46]| -40 to 115 [-40 to 46]
Heating| ºF DB [ºC DB]| —| —| —| —| —| —

Notes:

  • AHRI Rated Conditions 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed)

Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Wind baffles required to operate below 23°F DB in cooling mode. PUY with wind baffle: -40°F – 115°F. Refer to wind baffle documentation for further information.

SEACOAST PROTECTION

  • External Outer Panel: Phosphate coating + Acrylic-Enamel coating
  • Fan Motor Support: Epoxy resin coating (at edge face)
  • Separator Assembly; Valve Bed: Epoxy resin coating (at edge face)
  • “Blue Fin” treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants.

Conditions for Specifications

Temperature conditions are based on AHRI 210/240.

Cooling

| Indoor| D.B. 80º F (27º C), W.B. 67º F (19º C)
---|---|---
Outdoor| D.B. 95º F (35º C), W.B. 75º F (24º C)

Heating

| Indoor| D.B. 70º F (21º C), W.B. 60º F (16º C)
Outdoor| D.B. 17º F (-8º C), W.B. 15º F (-9º C)

Refrigerant piping length : 16ft.
The figures for total input are based on the following voltages.

Series Indoor unit Outdoor unit

M Series

P Series

MXZ-C Model

| ****

| ****

208 / 230V • Single phase • 60Hz

Sound pressure level

  • The sound pressure measurement is conducted in an anechoic chamber
  • The actual sound level depends on the distance from the unit and the acoustic environment.

How to Read a Model Name

M-Series MSZ-EF12NAWMITSUBISHI-ELECTRIC-P-Series-Wall-Mounted-Air-
Conditioning-System-fig- \(15\)

P-Series PUZ-A18NKAMITSUBISHI-ELECTRIC-P-Series-Wall-Mounted-Air-
Conditioning-System-fig- \(16\)

MXZ-C Model MXZ-4C36NAHZMITSUBISHI-ELECTRIC-P-Series-Wall-Mounted-Air-
Conditioning-System-fig- \(17\)

Optional Parts List for Outdoor

  PUY

PUY-A12NKA7(-BS)

| ****

PUY-A18NKA7(-BS)

| ****

PUY-A24NHA7(-BS)

| ****

PUY-A30NHA7(-BS)

| ****

PUY-A36NKA7(-BS)

| ****

PUY-A42NKA7(-BS)


Air Outlet Guide

| Air Outlet Guide| PAC-SJ07SG-E| •| •|  |  |  |
Air Outlet Guide (1 Piece)| PAC-SG59SG-E|  |  | •| •|  |
PAC-SH96SG-E|  |  |  |  | •| •
Centralized Drain Pan| Centralized Drain Pan| PAC-SG63DP-E| •| •|  |  |  |
Drain Pan| PAC-SG64DP-E|  |  | •| •|  |


Control/Service Tool

| Control/Service Tool| PAC-SK52ST| •| •| •| •| •| •
M- & P-Series Maintenance Tool Cable Set| M21EC0397| •| •| •| •| •| •
USB/UART Conversion Cable (Required for all laptop connection)| M21EC1397| •| •| •| •| •| •
Distribution pipe| Twinning Distribution Pipe (50:50)| MSDD-50TR-E|  |  | •| | •|
Drain Socket| Drain Socket| PAC-SG61DS-E|  |  | •| •| •| •
PAC-SJ08DS-E| •| •|  |  |  |
Hail Guards| Hail Guard| HG-A5| •| •|  |  |  |
HG-A6|  |  | •| •|  |


M-NET Converter

| ****

M-NET Converter

| PAC-SJ85MA-E|  |  | •| •| •| •
PAC-SJ95MA-E|  |  | •| •| •| •
PAC-SJ96MA-E| •| •|  |  |  |


Mini-Split Wire

| 14 Gauge, 4 wire MiniSplit Cable—250 ft. roll| S144-250| •| •| •| •| •| •
14 Gauge, 4 wire MiniSplit Cable—50 ft. roll| S144-50| •| •| •| •| •| •
16 Gauge, 4 wire MiniSplit Cable—250 ft. roll| S164-250| •| •| •| •| •| •
16 Gauge, 4 wire MiniSplit Cable—50 ft. roll| S164-50| •| •| •| •| •| •
Mounting Pad| Condensing Unit Mounting Pad: 16” x 36” x 3”| ULTRILITE1| •| •| |  |  |
Condensing Unit Mounting Pad: 24” x 42” x 3”| ULTRILITE2|  |  | •| •| •| •





Stand

| 18” Dual Fan Stand| QSMS1802M|  |  |  |  | •| •
18” Single Fan Stand| QSMS1801M| •| •| •| •|  |
24” Dual Fan Stand| QSMS2402M|  |  |  |  | •| •
24” Single Fan Stand| QSMS2401M| •| •| •| •|  |
Condenser Wall Bracket| QSWB2000M-1| •| •| •| •| •| •
Condenser Wall Bracket -Stainless Steel Finish| QSWBSS| •| •| •| •| •| •
Outdoor Unit Stand — 12” High| QSMS1201M| •| •| •| •|  |
QSMS1202M|  |  |  |  | •| •





Wind Baffle

| ****

Front Wind Baffle

| WB-PA3|  |  |  |  | •| •
WB-PA4| •| •|  |  |  |
WB-PA5|  |  | •| •|  |


Rear Wind Baffle

| WB-RE4| •| •|  |  |  |
WB-RE5|  |  | •| •|  |
WB-RE6|  |  |  |  | •| •


Side Advanced Wind Baffle

| WB-SD4| •| •|  |  |  |
WB-SD5|  |  | •| •|  |
WB-SD6|  |  |  |  | •| •

P-SeriesMITSUBISHI-ELECTRIC-P-Series-Wall-Mounted-Air-Conditioning-
System-fig- \(13\) MITSUBISHI-ELECTRIC-P-Series-Wall-Mounted-Air-Conditioning-System-fig-
\(14\)

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Mitsubishi Electric User Manuals

Related Manuals