MITSUBISHI ELECTRIC P-Series Wall Mounted Air Conditioning System User Guide
- June 12, 2024
- Mitsubishi Electric
Table of Contents
- MITSUBISHI ELECTRIC P-Series Wall Mounted Air Conditioning System
- Product Information
- Product Usage Instructions
- P-Series Model Reference Guide
- P-Series Product Lineup
- Industry Leading Energy Efficiency
- PLA Model
- Remote Controller
- Conditions for Specifications
- How to Read a Model Name
- Optional Parts List for Outdoor
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MITSUBISHI ELECTRIC P-Series Wall Mounted Air Conditioning System
Product Information
- The P-Series Model Reference Guide provides detailed information about the P-Series lineup of indoor and outdoor units. The P-Series includes six indoor units and three categories of outdoor units, allowing users to build a system that best matches their heating and cooling needs. The units are designed for professional use and offer high energy efficiency, thanks to a newly designed compressor and advanced variable-speed INVERTER-drive technology.
- The indoor units include wall-mounted, ceiling-suspended, ceiling cassette, and horizontal-ducted options. The outdoor units are available in cooling only, heat pump, and hyper-heating models.
- The P-Series lineup offers industry-leading energy efficiency and advanced energy-saving technologies.
Product Usage Instructions
To use the P-Series system, follow these steps:
Step 1: Select your Indoor Unit
- Choose from the following indoor units:
- Wall-mounted PKA-HA
- 4-Way Ceiling Cassette PLA
- Wall-mounted PKA-KA
Step 2: Select your Outdoor Unit
- Choose from the following outdoor unit options:
- Cooling Only:
- Ceiling-concealed PEAD
- Multi-position Air Handler PVA
- Ceiling-suspended PCA
- Heat Pump:
- PUY-A12NKA7
- PUY-A18NKA7
- PUY-A24NHA7
- PUY-A30NHA7
- PUY-A36NKA7
- PUY-A42NKA7
- PUZ-A12NKA7
- PUZ-A18NKA7
- PUZ-A24NHA7
- PUZ-A30NHA7
- PUZ-A36NKA7
- PUZ-A42NKA7
- PUZ-HA24NHA1
- PUZ-HA30NKA
- PUZ-HA36NKA
- PUZ-HA42NKA1
Note : The selection of indoor and outdoor units should be based on the
specific heating and cooling requirements of your application.
For further information and details about the P-Series lineup, please refer to
the complete user manual.
P-Series Model Reference Guide
- Designed for light commercial installations. Ideal for applications requiring year-round, low ambient cooling such as computer, elevator and equipment rooms
- Hyper-Heating INVERTER® (H2i®) outdoor units can provide superior heating performance at lower ambient temperatures
- Long lineset lengths
- Outside air intake on PLA, PCA, PEAD and PVA models
- P-Series ducted units have higher static than most M-Series, allowing for design flexibility
P-Series Product Lineup
The P-Series lineup includes a selection of six indoor units and three categories of outdoor units. You can easily build a system that best matches the application’s heating and cooling needs.
Step 1: Select your Indoor Unit
Step 2: Select your Outdoor Unit
Choose from Cooling Only, Heat Pump, or Hyper-heating models.
Cooling Only
Heat Pump
Hyper-Heating INVERTER® Heat Pump
P-Series
Industry-leading energy efficiency has been achieved by optimizing a newly
designed compressor and using the latest energy-saving technologies. All
compressors offer high performance due to advanced variable-speed INVERTER-
drive technology, which varies the compressor speed dynamically to adapt to
the room’s conditioning requirements.
Industry Leading Energy Efficiency
Industry-leading energy efficiency has been achieved through optimization of a newly designed compressor and the use of the latest energy-saving technologies. All compressors offer high performance due to advanced variable- speed INVERTER-drive technology, which varies the compressor speed dynamically to continuously adapt to the conditioning requirements of the room .
Advanced Energy-Saving Technology
Highly efficient fan for outdoor unit Fan opening of 21-3/4” (A36-42)
The opening for the fan in the outdoor unit is 21-3/4” in diameter. Exchanging
heat more efficiently contributes to increased energy-savings and lower noise
levels.
Highly efficient heat exchanger
High-density heat exchanger (A36-42)
The A36-42 units use a 5/16” diameter pipe. The high-density heat exchanger
contributes to efficient heat exchange and reduces the amount of refrigerant
used, which benefits the environment.
Improved fan (A36-42)
A newly designed fan increases airflow capacity and reduces operation noise.
PLA Model
Remote Controller
Model Selection
Cooling Only
Indoor Unit| | | | PLA- A12EA7| PLA- A18EA7|
PLA- A24EA7| PLA- A30EA7| PLA- A36EA7| PLA-
A42EA7
---|---|---|---|---|---|---|---|---|---
Outdoor Unit| | | | PUY-A12NKA7(- BS)| PUY-
A18NKA7(- BS)| PUY-A24NHA7(- BS)| PUY-A30NHA7(- BS)|
PUY-A36NKA7(- BS)| PUY-A42NKA7(- BS)
Cooling
| Capacity| Rated 1| BTU/H| 12,000| 18,000| 24,000| 30,000| 36,000| 42,000
Capacity Range| Min-Max| BTU/H| 5,800–12,000| 8,000–18,000| 10,000–24,000|
9,000–30,000| 16,000–36,000| 16,000–42,000
Power Input| Rated 1| W| 730| 1,250| 1,670| 2,540| 2,780| 3,590
Moisture Removal| Pints/h| 1.2| 2.4| 3.0| 5.4| 4.5| 7.9
Sensible Heat Factor| 0.890| 0.850| 0.860| 0.800| 0.860| 0.790
Heating
| Capacity at 47ºF| Rated| BTU/H| —| —| —| —| —| —
Capacity Range| Min-Max| BTU/H| —| —| —| —| —| —
Power Input at 47ºF| Rated| W| —| —| —| —| —| —
Capacity at 17ºF| Rated| BTU/H| —| —| —| —| —| —
Max| BTU/H| —| —| —| —| —| —
Capacity at 5ºF| Max| BTU/H| —| —| —| —| —| —
Capacity at -5ºF| Max| BTU/H| —| —| —| —| —| —
Efficiency
| SEER| 27.0| 24.6| 24.2| 22.8| 21.8| 21.0
EER| 16.4| 14.4| 14.3| 11.8| 12.9| 11.6
HSPF| —| —| —| —| —| —
COP| —| —| —| —| —| —
ENERGY STAR® Certified| Yes| Yes| Yes| No| Yes| No
Indoor Unit
| Air Flow Rate – Cooling (Quiet-Lo-Med-Hi-SHi)| Dry| CFM| 420–460–490–530| 420–460–570–600| 530–640–710–810| 570–670–780–880| 670–850–1020–
1200
| 740–920–1060–
1200
Air Flow Rate – Cooling (Quiet-Lo-Med-Hi-SHi)| Wet| CFM| 380–420–450–490| 380–420–530–560| 490–600–670–770| 530–630–740–840| 630–810–980–1160| 700–880–1020–
1160
Air Flow Rate – Heating (Quiet-Lo-Med-Hi-SHi)| Dry| CFM| 420–460–490–530| 420–460–570–600| 530–640–710–810| 570–670–780–880| 670–850–1020–
1200
| 740–920–1060–
1200
Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)| Cooling| dB(A)| 27–28–29–30|
28–29–31–32| 28–30–33–36| 28–32–35–38| 32–37–41–44| 34–38–42–45
Sound Pressure Level (Quiet- Lo-Med-Hi-SHi)| Heating| dB(A)| 27–28–29–30|
28–29–31–32| 28–30–33–36| 28–32–35–38| 32–37–41–44| 34–38–42–45
External Static Pressure| In. W.G.| —| —| —| —| —| —
Condensate Lift Mechanism| Max Distance| In. [mm]| 33-7/16 [849]| 33-7/16
[849]| 33-7/16 [849]| 33-7/16 [849]| 33-7/16 [849]| 33-7/16 [849]
Dimensions
| H| In. [mm]| 10-5/32 // 1-9/16 [258 // 40]| 10-5/32 // 1-9/16 [258 // 40]| 11-3/4 // 1-9/16 [298
// 40]
| 11-3/4 // 1-9/16 [298
// 40]
| 11-3/4 // 1-9/16 [298
// 40]
| 11-3/4 // 1-9/16 [298
// 40]
W| In. [mm]| 33-1/16 // 37-13/32 [840 // 950]| 33-1/16 // 37-13/32 [840 //
950]| 33-1/16 // 37-13/32 [840 // 950]| 33-1/16 // 37-13/32 [840 // 950]|
33-1/16 // 37-13/32 [840 // 950]| 33-1/16 // 37-13/32 [840 // 950]
D| In. [mm]| 33-1/16 // 37-13/32 [840 // 950]| 33-1/16 // 37-13/32 [840 //
950]| 33-1/16 // 37-13/32 [840 // 950]| 33-1/16 // 37-13/32 [840 // 950]|
33-1/16 // 37-13/32 [840 // 950]| 33-1/16 // 37-13/32 [840 // 950]
Weight| lbs [kg]| 46 // 11 [21 // 5]| 46 // 11 [21 // 5]| 56 // 11 [25 // 5]|
56 // 11 [25 // 5]| 56 // 11 [25 // 5]| 56 // 11 [25 // 5]
Outdoor Unit
| MCA| A| 11.0| 11.0| 19.0| 19.0| 25.0| 25.0
MOCP| A| 28| 28| 26| 26| 31| 31
Dimensions
| H| In. [mm]| 24-13/16 [630]| 24-13/16 [630]| 37-1/8 [943]| 37-1/8 [943]|
52-11/16 [1338]| 52-11/16 [1338]
W| In. [mm]| 31-13/16 (+7/16) [809 (+62)]| 31-13/16 (+7/16) [809 (+62)]|
37-13/32 [950]| 37-13/32 [950]| 41-5/16 [1050]| 41-5/16 [1050]
D| In. [mm]| 11-3/16 [300]| 11-3/16 [300]| 13 (+1-3/16) [330
(+30)]
| 13 (+1-3/16) [330
(+30)]
| 13 (+1-3/16) [330
(+30)]
| 13 (+1-3/16) [330
(+30)]
Weight| lbs [kg]| 92 [41]| 99 [44]| 151 [68]| 151 [68]| 211 [96]| 211 [96]
Air Flow Rate (Cooling/ Heating)| CFM| 1590/—| 1590/—| 1940/—| 1940/—| 3880/—|
3880/—
Sound Pressure Level| Cooling| dB(A)| 44| 44| 47| 47| 52| 52
Heating| dB(A)| —| —| —| —| —| —
Piping
|
Diameter
| Gas (O.D.)| In. [mm]| 1/2 [12.7]| 1/2 [12.7]| 5/8 [15.88]| 5/8 [15.88]| 5/8
[15.88]| 5/8 [15.88]
Liquid (O.D)| In. [mm]| 1/4 [6.35]| 1/4 [6.35]| 3/8 [9.52]| 3/8 [9.52]| 3/8
[9.52]| 3/8 [9.52]
Indoor Drain| In. [mm]| 1-1/4 [32]| 1-1/4 [32]| 1-1/4 [32]| 1-1/4 [32]| 1-1/4
[32]| 1-1/4 [32]
Max. Length| ft [m]| 165 [50]| 165 [50]| 225 [68]| 225 [68]| 225 [68]| 225
[68]
Max. Height| ft [m]| 100 [30]| 100 [30]| 100 [30]| 100 [30]| 100 [30]| 100
[30]
Electrical| Outdoor-Indoor5| V, ph, Hz| 208/230, 1, 60| 208/230, 1, 60|
208/230, 1, 60| 208/230, 1, 60| 208/230, 1, 60| 208/230, 1, 60
Recommended Breaker Size| A| 15| 15| 25| 25| 30| 30
Refrigerant Type| R410A| R410A| R410A| R410A| R410A| R410A
Guaranteed Temperature Operation Range| Cooling6| ºF DB [ºC DB]| -40 to 115
[-40 to 46]| -40 to 115 [-40 to 46]| -40 to 115 [-40 to 46]| -40 to 115 [-40
to 46]| -40 to 115 [-40 to 46]| -40 to 115 [-40 to 46]
Heating| ºF DB [ºC DB]| —| —| —| —| —| —
Notes:
- AHRI Rated Conditions 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed)
Indoor units receive power from outdoor units through field-supplied
interconnected wiring.
Wind baffles required to operate below 23°F DB in cooling mode. PUY with wind
baffle: -40°F – 115°F. Refer to wind baffle documentation for further
information.
SEACOAST PROTECTION
- External Outer Panel: Phosphate coating + Acrylic-Enamel coating
- Fan Motor Support: Epoxy resin coating (at edge face)
- Separator Assembly; Valve Bed: Epoxy resin coating (at edge face)
- “Blue Fin” treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants.
Conditions for Specifications
Temperature conditions are based on AHRI 210/240.
Cooling
| Indoor| D.B. 80º F (27º C), W.B. 67º F (19º C)
---|---|---
Outdoor| D.B. 95º F (35º C), W.B. 75º F (24º C)
Heating
| Indoor| D.B. 70º F (21º C), W.B. 60º F (16º C)
Outdoor| D.B. 17º F (-8º C), W.B. 15º F (-9º C)
Refrigerant piping length : 16ft.
The figures for total input are based on the following voltages.
Series | Indoor unit | Outdoor unit |
---|
M Series
P Series
MXZ-C Model
| ****
–
| ****
208 / 230V • Single phase • 60Hz
Sound pressure level
- The sound pressure measurement is conducted in an anechoic chamber
- The actual sound level depends on the distance from the unit and the acoustic environment.
How to Read a Model Name
M-Series MSZ-EF12NAW
P-Series PUZ-A18NKA
MXZ-C Model MXZ-4C36NAHZ
Optional Parts List for Outdoor
PUY |
---|
PUY-A12NKA7(-BS)
| ****
PUY-A18NKA7(-BS)
| ****
PUY-A24NHA7(-BS)
| ****
PUY-A30NHA7(-BS)
| ****
PUY-A36NKA7(-BS)
| ****
PUY-A42NKA7(-BS)
Air Outlet Guide
| Air Outlet Guide| PAC-SJ07SG-E| •| •| | | |
Air Outlet Guide (1 Piece)| PAC-SG59SG-E| | | •| •| |
PAC-SH96SG-E| | | | | •| •
Centralized Drain Pan| Centralized Drain Pan| PAC-SG63DP-E| •| •| | | |
Drain Pan| PAC-SG64DP-E| | | •| •| |
Control/Service Tool
| Control/Service Tool| PAC-SK52ST| •| •| •| •| •| •
M- & P-Series Maintenance Tool Cable Set| M21EC0397| •| •| •| •| •| •
USB/UART Conversion Cable (Required for all laptop connection)| M21EC1397| •|
•| •| •| •| •
Distribution pipe| Twinning Distribution Pipe (50:50)| MSDD-50TR-E| | | •|
| •|
Drain Socket| Drain Socket| PAC-SG61DS-E| | | •| •| •| •
PAC-SJ08DS-E| •| •| | | |
Hail Guards| Hail Guard| HG-A5| •| •| | | |
HG-A6| | | •| •| |
M-NET Converter
| ****
M-NET Converter
| PAC-SJ85MA-E| | | •| •| •| •
PAC-SJ95MA-E| | | •| •| •| •
PAC-SJ96MA-E| •| •| | | |
Mini-Split Wire
| 14 Gauge, 4 wire MiniSplit Cable—250 ft. roll| S144-250| •| •| •| •| •| •
14 Gauge, 4 wire MiniSplit Cable—50 ft. roll| S144-50| •| •| •| •| •| •
16 Gauge, 4 wire MiniSplit Cable—250 ft. roll| S164-250| •| •| •| •| •| •
16 Gauge, 4 wire MiniSplit Cable—50 ft. roll| S164-50| •| •| •| •| •| •
Mounting Pad| Condensing Unit Mounting Pad: 16” x 36” x 3”| ULTRILITE1| •| •|
| | |
Condensing Unit Mounting Pad: 24” x 42” x 3”| ULTRILITE2| | | •| •| •| •
Stand
| 18” Dual Fan Stand| QSMS1802M| | | | | •| •
18” Single Fan Stand| QSMS1801M| •| •| •| •| |
24” Dual Fan Stand| QSMS2402M| | | | | •| •
24” Single Fan Stand| QSMS2401M| •| •| •| •| |
Condenser Wall Bracket| QSWB2000M-1| •| •| •| •| •| •
Condenser Wall Bracket -Stainless Steel Finish| QSWBSS| •| •| •| •| •| •
Outdoor Unit Stand — 12” High| QSMS1201M| •| •| •| •| |
QSMS1202M| | | | | •| •
Wind Baffle
| ****
Front Wind Baffle
| WB-PA3| | | | | •| •
WB-PA4| •| •| | | |
WB-PA5| | | •| •| |
Rear Wind Baffle
| WB-RE4| •| •| | | |
WB-RE5| | | •| •| |
WB-RE6| | | | | •| •
Side Advanced Wind Baffle
| WB-SD4| •| •| | | |
WB-SD5| | | •| •| |
WB-SD6| | | | | •| •
P-Series
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>