KATHREIN VOS 137-RA 2.0 House Connection Amplifier User Manual
- June 12, 2024
- KATHREIN
Table of Contents
VOS 137-RA 2.0 House Connection Amplifier
User Manual VOS 137/RA 2.0
VOS 138/RA 2.0
VOS 139/RA 2.0
House connection amplifier
Features
- House connection amplifier for modern HFC networks
- VOS 137/RA 2.0 – locally fed VOS 138/RA 2.0 – remotely fed via RF input (auto-supply) VOS 139/RA 2.0 – remotely fed
- Very high output level with good energy balance
- Modern GaAs-MMIC technology
- Highly efficient switched-mode power supply unit
- New innovative operational concept: – Simplified levelling using rotary switch, large adjustment range (20 dB), small step width (1 dB) – Basic configuration via jumpers – Exactly reproducible device settings
- Insert position for additional functions in the forwards path (e.g. de-emphasis, system equaliser)
- Gain is switchable 40/34/30 dB with interstate attenuation using jumper (setting as supplied: 34 dB)
- Diplexer can be bypassed (I-band operation available with no return path)
- Integrated return path (active/passive/disabled) with numerous setting facilities
- Classification to KDG 1 TS 140: Type D (4.4)
- Test sockets (F connectors): – two-way on the input (switchable) – with directional coupler on the output
- Test sockets are terminated with the EMK 03 in the delivery status
- Internal LED function indicator
- Voltage surge conductors on input and output
- Comprehensive remote feeding concept (VOS 139/RA 2.0): – Remote feed current: max. 5 A – Remote feed voltage: 32-65 V– Remote feed possibilities: Optionally via RF input and RF output as well as via local connection (power passing)
- In conformity with: EN 60728-11, EN 50083-2 and EN 62368-1
- Die-cast housing with F connections (VOS 137/RA 2.0, VOS138/RA 2.0) or PG 11 connections (VOS 139/RA 2.0: order cable fittings separately, not included in the scope of delivery)
- For use in locations protected from weather conditions
- The amplifiers comply with the requirements of the EMC Directive 2014/30/EU and Low-Voltage Directive 2014/35/EU applicable at the time of shipping
Basic safety precautions
- Installation must be carried out by authorised specialist staff.
- Described amplifiers are exclusively for installation of HFC networks up to 1006 MHz
- Any other use or failure to comply with these instructions will invalidate the warranty.
- The amplifiers may only be installed in dry indoor areas. Do not install on or against highly combustible materials.
- The safety regulations set out in the current EN 60728-11 and EN 62368-1 standards must be complied with.
- The supply voltage of the amplifiers is 32-65 V or 230 V AC. This can give a fatal shock if touched!
- The only reliable method of disconnecting the amplifiers from the mains is to disconnect the power plug (VOS 137/RA 2.0).
- Do not touch live parts. This also applies after removing the device’s internal fuse.
- The power plug must be easily operable as the means of cutting power to the amplifier, meaning the wall outlet must be close to the amplifier and easily accessible. Always disconnect the power plug during installation.
- Only install or reinstall the amplifier in the de-energized condition.
- The amplifiers must not be operated without the standard fitted power supply unit guard cover. The cover must be closed.
- No liquid-filled items may be placed on top of the amplifiers.
- The amplifiers must not be exposed to dripping or splashing water.
- Permissible ambient temperature -20 to +55°C
- The remote power feed transformer or converter required for supplying the VOS 138/RA 2.0 and VOS 139/RA 2.0 must comply with protection class II and with EN 62368-1. Its maximum fault current (short-circuit current) may not exceed double the nominal current value. Recommendation for VOS 138/RA 2.0 and VOS 139/RA 2.0: TVF 20 (BN 236678).
Installation instructions for remotely fed devices (VOS 138/RA 2.0, VOS
139/RA 2.0)
In accordance with EN 60728-11, remote feed voltages up to a maximum of 65 V
AC are permissible. Voltages above 50 V AC are already considered dangerous to
touch. Therefore they may not be accessible to laymen and only accessible to
persons with electrical instruction by using tools. If the shield of the
current-carrying coaxial cable (outer conductor) is broken at any point the
remote power feed may appear at the metal housing of the device (touch
hazard!). Therefore the outer conductor connection of the remote feed cable
may never be separated before its inner conductor connection (for safety,
always switch off the remote feed). Great care must be taken in establishing a
safe outer conductor contact (be sure to follow the manufacturers
instructions!).
Protective measures
Potential equipotential by local earthing point An additional connection to
earth potential must be made at the earthing point of the device by way of a
copper conductor with at least 4 mm2 cross-section. This connection can be
made to an existing earthing rail or a local earth for example.
If this cannot be achieved, one of the following protective measures may be
taken:
a) Potential equalisation by minimum cross section of the coaxial cable It
must be ensured at all times that the remote feed coaxial cable has an outer
conductor cross-section of at least 4 mm2 along its entire length (from the
feed-in point) (Note: braided cables do not generally have this cross
section).
Or
b) Potential equalisation by several connected cables It must be ensured that
at least one other coaxial cable is permanently connected to earth potential
on its shield along its entire length.
Or
c) Potential equalisation in manual range Potential equalisation must be
carried out in the manual range of the device, i.e. within 2.50 m. For this,
all live parts within this range must be connected to the device by way of at
least a 4 mm2 copper conductor.
Or
d) Protection against contact by installation in closed operating rooms
Remotely powered devices must be operated in locked operating rooms. A
relevant warning (such as a lightning symbol and the phrase “Shock hazard in
case of fault”) must be affixed indicating that in the event of a fault supply
voltage potential may be connected to the unit chassis. Cables leading
directly to the subscriber must in this case be equipped with electrical
isolation on the outer conductor.
Or
e ) Maximum remote feed voltage limited to 50 V AC
The remote feed voltage in the system may not exceed a max. 50 V AC.
When supplying multiple VOS 139/RA 2.0 (via direct connection), it is
essential to ensure the correct polarity! Risk of short circuits!
Optional accessories
De-emphasis equaliser: ERD 810, ERD 813, ERZ 940
Pre-emphasis equaliser: ERZ 630, ERS 800
Cable fittings: EMP 26, EMP 28, EMP 34, EMP 35
Remote feed transformer: TVF 20
Test sockets
Test socket on the amplifier input 5-1006 MHz two-way (switchable) dB -20
Test socket on the amplifier output 5-1006 MHz with directional coupler dB -20
Test signals for the return path can be injected at the output test socket.
Installation
Current-carrying unit!
Always disconnect the power plug and switch off the remote feed prior to
installation.
Safety regulations to EN 60728-11 and EN 62368-1 must be complied with.
Mount the amplifier vertically with the cable input facing down. Ensure
sufficient air circulation around all sides.
Install correctly in accordance with EN 60728-11.
The connected network must be earthed in accordance with regulations, even if
the amplifier has been removed.
Only qualified personnel are permitted to perform servicing work.
– The specified torques must be adhered to for compliance with the electrical
and mechanical data.
– Wall attachment to be performed using dowel screws with a thread diameter of
5-6 mm
For installation you need:
- Fixings: Screws, max. Ø: 4.5 mm
- F connector in compliance with EN 61169-24.
If the cable inner conductor diameter is greater than 1.2 mm, or in case of burr, the device sockets may be destroyed.
Installation of the RF cable connection fitting (VOS 139/RA 2.0)
When installing the RF cable connection fittings (PG 11), the fitting
manufacturer’s instructions should be complied with.
Safety instructions:
There may already be a remote feed voltage applied to the RF cable!
Installation 1) Completely unscrew the inner conductor clamp
procedure: 2) Screw in the PG 11 fitting
3) Tighten the inner conductor clamp (MA19 ± 1 = 1-1.2 Nm)
Required tools: – Screwdriver for socket-head screws 5 AF (housing cover), MA
: 5-6 Nm
– Screwdriver for socket-head screws 2 AF (inner conductor clamp)
– Open-ended wrench 22 AF (PG 11 fitting)
Shorten the inner conductor to the specified length, leaving no burrs. Longer
inner conductors can lead to defects.
Operating elements and insert positions (Fig. VOS 139/RA 2.0)
Position “A” and “B”: Position of the fuses for remote feeding
VOS 138/RA 2.0:
- Fuse T2AH/250 V with insert holder in position “A” as power supply unit fuse
VOS 139/RA 2.0:
- 2 fuses T6.3AH/250V with insert holders (included in the scope of delivery)
- Fuse fitted in position A: Remote feeding via the input
- Fuse fitted in position B: Remote feeding via the output
- Both fuses fitted in position A and B: Remote feeding via input or output with through feed
The remote feed fuses function as connection elements.
Overview of controls
The basic configuration of the device is made using jumpers:
Operating mode: Operation only with forwards path, including band I (47-1006
MHz) or
Operation with return path (5 – 65 MHz) and forwards path (85-1006 MHz)
Forwards path:
Return path:
Setting for the gain (40 / 34 / 30 dB) via interstate attenuation
Setting for the interstate pre-emphasis (0 / 6 dB)
Setting for the operating mode for the return path amplifier active / passive
/
switched off
Connection of an attenuation (10 dB) to the input of the return path amplifier
Setting for the interstate pre-emphasis (0 / 3 / 6 dB)
Adding a pre-emphasis (3 dB) to the input of the return path amplifier
Test socket 1:
Option:
The test socket 1 must be enabled during the measurement.
Insert position for additional functions in the forwards path
The amplifier is levelled using rotary switches:
Element | Delivery status |
---|---|
X1, X2, X3, X4 | X |
X5 | 34 dB |
X6 | 6 dB |
X7, X8 | switched off |
X9 | 10 dB |
X10 | 0 dB |
X13 | 0 dB |
X11 | switched off |
X12 | 0 dB bridge |
S1 | 20 dB |
S2 | 0 dB |
S3 | 0 dB |
Forwards path: Setting for the attenuation on the amplifier input (0 – 20 dB
in 1 dB steps) Setting for the equalization on the amplifier input (0 – 20 dB
in 1 dB steps)
Return path: Setting for the interstate attenuation (0 – 20 dB in 1 dB steps)
Set-up
Before switching on the amplifier, i.e. before connecting the remote feed path
that supplies power or connecting a remote feed transformer, make sure that:
- The RF cable connections on the amplifier’s inputs and outputs are correctly installed and connected
- The fuses (= connection elements) in the RF paths, through which the remote power feed is planned to be delivered and which at this point in time already can be delivered (involving perhaps installation work at the next downstream amplifier point), have been inserted.
Do not switch on the AC remote feed voltage at the VOS 138/RA 2.0 and VOS
139/RA 2.0 until the amplifier has been fully installed, i.e. only after the
RF connections and the potential equalization have been connected.
An external remote feed voltage on the VOS 139/RA 2.0 (power passing) is
connected using the specified terminal in the power supply casing (max. 5 A).
Use only genuine fuses and power cables as replacements!
■ Replacement fuses:
T 800mAE 250 V BN 094 070
T 2AH 250 V BN 094 039
T 6.3AH 250 VBN 094 078
If several amplifiers are fed from one remote feeding transformer, it is
crucial to ensure that the polarity is correct! Risk of short circuits!
The spare parts can be obtained through:
atonic electronic-service GmbH
Hauptstraße 2a
35798 Langberg-Oberhausen
Telecon +49 6477 6123 101
Fax +49 6477 6123 020
E-Mail: service-kathrein@autronic-service.de
Before changing the power supply unit fuse or the remote feed fuses (= connection elements) always disconnect the power plug or disconnect the remote feed voltage!
Remote feeding (VOS 138/RA 2.0, VOS 139/RA 2.0)
Connection example
![KATHREIN VOS 137 RA 2.0 House Connection Amplifier - RQH[DPSOH](https://manuals.plus/wp-content/uploads/2023/08/KATHREIN- VOS-137-RA-2.0-House-Connection-Amplifier-RQHDPSOH.png)
Technical specifications
Type | VOS 137/RA 2.0 | VOS 138/RA 2.0 | VOS 139/RA 2.0 | |
---|---|---|---|---|
Part no. | 209500003 | 209500004 | 209500005 | |
Forward path | ||||
Frequency range 1) | MHz | 47/85-1006 | 47/85-1006 | 47/85-1006 |
Gain | dB | 40/34/30 | 40/34/30 | 40/34/30 |
Adjustable attenuator adjustment range | dB | 0-20 | 0-20 | 0-20 |
Equalization setting range | dB | 0-20 | 0-20 | 0-20 |
Interstate attenuation adjustment range | dB | 0/6/10 | 0/6/10 | 0/6/10 |
Interstate equalization adjustment range | dB | 0/6 | 0/6 | 0/6 |
Maximum operating level at 862 MHz 2) with 6 dB interstate pre-emphasis (60 dB
CTB/CSO)| dB| 113/116| 113/116| 113/116
Noise figure (interstate attenuation 0/6/10 dB)| dB| Typ. 6/7/7| Typ. 6/7/7|
Typ. 6/7/7
Return path| | | |
Frequency range| MHz| 5-65| 5-65| 5-65
Gain
| – active| dB| 30| 30| 30
– passive| dB| -2| -2| -2
Input attenuation adjustment range| dB| 0/10| 0/10| 0/10
Interstate attenuation adjustment range| dB| 0-20| 0-20| 0-20
Interstate equalization adjustment range| dB| 0/3/6| 0/3/6| 0/3/6
Max. output level (60 dB IMA2/IMA3)| dB| 107/116| 107/116| 107/116
Maximum output level KDG 1 TS 140 (full system load)| dB| 120| 120| 120
Noise factor| dB| Typ. 5| Typ. 5| Typ. 5
Input level density (CINR at 50 dB, EN 60728-3; 4.7)| dB/Hz| -10| -10| -10
Dynamic range (EN 60728-3; 4.7)| dB| 17| 17| 17
Test sockets (F connector)| | | |
Amplifier input (5-1006 MHz, two-way)| dB| -20| -20| -20
Amplifier output (5-1006 MHz, with directional coupler)| dB| -20| -20| -20
Switched-mode power supply unit| | | |
Nominal input voltage| V~| 230| 32-65| 32-65
Typical nominal power consumption 3)| | | |
Return path passive or deactivated| W| 13| 14| 14
Return path active| W| 14| 15| 15
General information| | | |
Impedance input/output| Ohm| 75| 75| 75
RF connections| | F connector| F connector| PG 11
Remote feed power-capacity| A| –| –| 5
Hum-modulation ratio (forwards path/return path)| dB| –| –| 70/60
Protection class| | II| –| –
Protection class (in accordance with EN 60529) 5)| | IP 54| IP 54| IP 54
Temperature range| °C| -20 to +55| -20 to +55| -20 to +55
Dimensions| mm| 218 x 141 x 76| 218 x 141 x 76| 218 x 141 x 76
Packing unit/weight| Units/kg| 1 (10)/1.25| 1 (10)/1.25| 1 (10)/1.25
Classification to KDG 1 TS 140| | Type D (4.4)| Type D (4.4)| Type D (4.4)
- Frequency range from 47 MHz without return path use
- In accordance with EN 60728-3; CENELEC channel plan with 42 carriers
- VOS 138/RA 2.0 and VOS 139/RA 2.0: Nominal power consumption subject to the infeed voltage during operation via the cable resistance
- Outdoors use only in cabinets with protection against the weather
Block diagram (VOS 139/RA 2.0)
Electronic equipment
Electronic equipment is not domestic waste – in accordance with directive
2012/19/EU OF THE EUROPEAN PARLIAMENT AND THE COUNCIL dated 4th July 2012
concerning used electrical and electronic appliances, it must be disposed of
properly. At the end of its service life, take this unit for disposal at a
designated public collection point.
www.kathrein-ds.com | support@kathrein-
ds.com
936500141/a/A5/MK/0322/GB | Subject to change.
Phone +49 731 270 909 70
KATHREIN Digital Systems GmbH
Anton-Kathrin-Str. 1–3
83022 Rosenheim
Germany
936500141/a/A5/MK/0322/GB | Subject to change.
Documents / Resources
|
KATHREIN VOS 137-RA 2.0 House Connection
Amplifier
[pdf] User Manual
VOS 137-RA 2.0 House Connection Amplifier, VOS 137-RA 2.0, House Connection
Amplifier, Connection Amplifier, Amplifier
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>