Baumer PBM4 Pressure Transmitter Instruction Manual

June 12, 2024
Baumer

Pressure transmitter

Mounting instruction

Series

PBM4

Configuration

www.baumer.com

Baumer Electric AG · CH-8501 Frauenfeld
Phone +41 (0)52 728 1122 · Fax +41 (0)52 728 1144

Canada

Baumer Inc.
CA-Burlington, ON L7M 4B9
Phone +1 (1)905 335-8444

China

Baumer (China) Co., Ltd.
CN-201612 Shanghai
Phone +86 (0)21 6768 7095

Denmark

Baumer A/S
DK-8210 Aarhus V
Phone +45 (0)8931 7611

France

Baumer SAS

FR-74250 Fillinges
Phone +33 (0)450 392 466
Germany

Baumer GmbH
DE-61169 Friedberg
Phone +49 (0)6031 60 07 0

India

Baumer India Private Limited
IN-411038 Pune
Phone +91 20 2528 6833/34

Italy

Baumer Italia S.r.l.
IT-20090 Assago, MI
Phone +39 (0)2 45 70 60 65

Singapore

Baumer (Singapore) Pte. Ltd.
SG-339412 Singapore
Phone +65 6396 4131

Sweden

Baumer A/S
SE-56133 Huskvarna
Phone +46 (0)36 13 94 30

Switzerland

Baumer Electric AG
CH-8501 Frauenfeld
Phone +41 (0)52 728 1313

United Kingdom

Baumer Ltd.
GB-Watchfield, Swindon, SN6 8TZ
Phone +44 (0)1793 783 839

USA

Baumer Ltd.
US-Southington, CT 06489
Phone +1 (1)860 621-2121

www.baumer.com/worldwide

Connection assignment

current output / voltage output

Electric connection diagram

supply voltage ……………V : 9…36 VDC (Class 2, UL 1310
→ or device shall be protected by an external R/C or Listed Fuse, rated max. 30VAC/3Amps or 24VDC/4Amps)

output signal …………………………I : 4…20 mA

supply voltage  V : 14…36 VDC (0..10 V) / 9…36 VDC (0…5 V, 1…6 V,0.5…4.5 V) / 5 VDC ± 10% (0.5…4.5 V ratio metric)

( Class 2, UL 1310 → or device shall be protected by an external R/C or Listed Fuse, rated max. 30VAC/3Amps or 24VDC/4Amps)

output signal …………V : 0…10 / 0…5 / 1…6 VDC / 0.5…4.5 VDC ratio metric / 0.5…4.5

Installation hints

Rules for proper usage

This product is a precision device which has been designed for the detection of pressures. It generates and provides measured values issued as electrical signals for following systems

Set-up

Installation, mounting and adjustment of this product may only be executed by skilled employees. The mounting and dismounting must be carried out with the power switched off and at zero pressure.

Installation in the pressure system

Use seals suitable for the pressure and the medium. If the seal is a metallic seal, it is recommended that the sealing surface should be lubricated with grease on an MoS2 or Vaseline basis.
When installing, the tightening torque may not exceed 35 Nm. Please use a suitable wrench for installation. Do not insert rigid elements into the pressure port (the diaphragm could be destroyed).

Electrical connection

Connect the pressure transmitter in accordance with the diagrams on page 1. Ensure that polarity is correct and use shielded cables. The transmitter housing and the cable shield must be grounded. Keep the connection of the shield on the controller side with a large contact area to achieve the best possible protection from electromagnetic interference. As far as possible, prevent potential differences between the housing of the transmitter and the controller. To comply with the PELV requirements in accordance with EN60204-1 §6.4.1, 0V (GND) must be connected to a point in the system with protective grounding. Do not expose the transmitter to humidity without the connector in place.

General notes:

Rules for proper usage

This product is a precision device which has been designed for the detection of pressures. It generates and provides measured values issued as electrical signals for following systems. Unless this product has not been specifically marked it may not be used in hazardous areas.

Set-up

Installation, mounting and adjustment of this product may only be executed by skilled employees.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals