PENTAIR 115-57 4 Pompe Immergee Dominator Instruction Manual

June 12, 2024
Pentair

DOMINATOR
Instruction Manual

253PA900-01 11/2021

Declaration of conformity

Directives – Harmonised standards

2006/42/EC (MD)
2014/30/EU (EMC)
2009/125/EC (ErP)
2011/65/EU (RoHS II)
2015/863/EU (RoHS III)| EN 60335-1:2012/A11:2014/A13:2008/A14:2010/A15:2011, EN ISO 12100:2010
EN 61000-6-3:2007/A1:2011, EN 61000-6-1:2007, EN 61000-6-4:2007/A1:2011,
EN 61000-6-2:2005, EN 55014-1:2006/A2:2011
EN50581:2012
---|---

Pentair Water Italy S.r.l. Corso Europa, 2 angolo via Trieste 20010 Lainate (MI) Italy

We hereby declare, under our sole responsibility, that the product is in accordance with the specified Directives.

DOMINATOR 4″ PLUS 55/50
DOMINATOR 4″ PLUS 75/35
DOMINATOR 4″ PLUS 75/56
DOMINATOR 4″ PLUS 75/75| DOMINATOR 4″ PLUS 115/36
DOMINATOR 4″ PLUS 115/57
DOMINATOR 4″ PLUS 115/70
DOMINATOR 5″ 70/50B| DOMINATOR 5″ 70/75B
DOMINATOR 5″ 140/45B
DOMINATOR 5″ 140/65B
---|---|---

Other normative documents
EN 60335-2-41:2003/A2:2010
Commission Regulation N.547/2012
Applies only to water pumps marked with the minimum efficiency index MEI. See pump nameplate.
Commission Regulation No 547/2012
Applies only to water pumps marked with the minimum

Authorized person for technical documentation

Pentair Water Italy S.r.l.
Corso Europa, 2 angolo via Trieste
20010 Lainate (MI) Italy

WARNINGS
For the safety of individuals and objects.
Carefully follow the instructions marked with the following symbols.

DANGER – ELECTRIC SHOCK RISK
Warns that the failure to follow the directions given may cause electric shock.
DANGER
Warns that the failure to follow the directions given could cause serious risk to individuals or objects.
WARNING
Warns that the failure to follow the directions given could damage the pump or the system.

WARNING
Read this manual carefully before installing this pump. Any damage caused by failure to observe the directions contained in this manual will not be covered by warranty.

CHAPTER 1 FEATURES

DOMINATOR electropumps are suitable to pump clear water that contains no dissolved gases.
The electropumps of this series are multiphase centrifugal and submergible pumps. The parts that come into contact with water are all suitable to be used with cooking water. Every electropump has been carefully tested and packed. On receiving the product, verify that the electropump has not been damaged during transport. If damage is reported, immediately contact the dealer within and no later than 8 days from the purchase date.

CHAPTER 2 LIMITATIONS

The efficiency of a pump with a trimmed impeller is usually lower than that of a pump with the full impeller diameter. The trimming of the impeller will adapt the pump to a fixed duty point, leading to reduced energy consumption. The minimum efficiency index (MEI) is based on the full impeller diameter. The operation of this water pump with variable duty points may be more efficient and economic when controlled, for example, by the use of a variable speed drive that matches the pump duty to the system  information on benchmark efficiency is available at: www.europump.org/efficiencycharts

WARNING
The electropump cannot be used to move inflammable or dangerous liquids.
WARNING
Verify that the electropump never runs without liquids.

  • Max. Temperature of pumped liquid 40° C continuous operation
  • Max. On/off cycles/hour 30 equally spaced
  • Max. Immersion depth 17 m
  • Maximum dimension of pumped solid objects 2 mm
  • Maximum amount of sand 50 g/m3
  • Minimum diameter of the well 135 mm DOMINATOR 5″ (without float)
  • Minimum diameter of the well 100 mm DOMINATOR 4″ (without float)

CHAPTER 3 INSTALLATION

DANGER – ELECTRIC SHOCK RISK
During installation, verify that the pump is disconnected from the electrical supply.
WARNING
Make sure that the float switch stops the pump, when the min. level of liquid is reached.
WARNING
Make sure no obstacles obstruct the movement of the float switch.
DANGER
This appliance can be used by children aged 8 years or over and by persons with limited physical, sensory or intellectual capabilities, or with limited experience and knowledge, provided that they are supervised or have been instructed in the safe use of the appliance and are aware of the dangers involved. Children must not be allowed to play with the appliance. Cleaning and user maintenance must not be carried out by children unless they are supervised.
DANGER
Pollution of the liquid could occur due to the leakage of lubricants

  • It is advisable to fit a check valve to prevent the fluid from re-circulating when the pump is stopped. Avoid using the electric cable to lift or transport the pump.
  • Use a stainless steel or nylon rope, suitable to sustain the weight, to immerse the electropump.
  • 1 slot only has been provided to anchor the electropump.
  • Anchor the rope so that it balances the weight of the electropump.
  • It is advisable to connect the electric cable to the delivery with plastic straps, at a distance of about 3 m, when using rigid piping.
  • It is also advisable to fit automatic level controls to prevent the electropump from running without liquids and a pressure gauge (suitable to the electropump model) to verify its performance during operation.
  • The automatic DOMINATOR model is equipped with a pre-set float switch (See fig.1). To change the adjustement range, increase or decrease the free piece of float switch cable by sliding it through the seat on the handlebar.

CHAPTER 4 ELECTRICAL CONNECTIONS

WARNING
Verify that the voltage and frequency of the electropump shown on the nameplate correspond to those available on the mains.
DANGER – ELECTRIC SHOCK RISK
The installer must make sure that the electric system is grounded in accordance with the law in force.
DANGER – ELECTRIC SHOCK RISK
Make sure that the electric system has a (RCD) high-sensitivity circuit breaker D=30 mA.

Electropumps have a plug with double ground contact at the end of the power supply cable. In this case the electropump is grounded by inserting the plug in the socket.
If the pump is provided without plug, the appliance is intended to be permanently connected to fixed wiring.
OVERLOAD PROTECTION
DOMINATOR is a single-phase electropump with in-built thermal circuit breaker and automatic reset and doesn’t therefore require any external protections.

CHAPTER 5 STARTING THE UNIT

WARNING
Use the electropump for the applications listed on the nameplate.
WARNING
Do not operate the electropump without liquids, to avoid damaging hydraulic parts and seal.
WARNING
Do not operate the electropump when the interception valve on the delivery side is completely closed.

Connect the pipe to the 1″ 1/4 delivery mouth before starting the electropump. Connections must be made so as to avoid losses.
Start the pump by inserting the plug in an appropriate outlet.

CHAPTER 6 MAINTENANCE AND TROUBLESHOOTING

DANGER – ELECTRIC SHOCK RISK
Make sure the machine is disconnected from electric power supply, before performing servicing operation.
DANGER – ELECTRIC SHOCK RISK
The power cord must be replaced by the manufacturer or the Customer service, using special tools.

  • Under normal conditions DOMINATOR electropumps do not need any type of maintenance. In order to avoid possible failures, it is advisable to periodically check the pressure supplied and current absorption.
  • A decrease in pressure is a symptom of wear. An increase in current absorption is a sign of abnormal mechanical friction in the pump and/or motor.
  • If the electropump is not going to be used for long periods of time it should be emptied completely, rinsed with clean water and put in a dry place.

CLEANING THE FILTER

  • If the sucked water is not perfectly clean, it may be necessary to clean the filter with a steel brush to scrape the dirt accumulated on the external surface.
  • It is also possible to clean the internal section of the filter.
  • Loosen the screw that fixes the filter to the body of the electropump and remove it.
  • Scrape the dirt with a steel brush and rinse it with clean water.
  • If this is not sufficient, have the hydraulic parts cleaned by an authorised centre.
PROBLEM POSSIBLE CAUSE REMEDY

THE ELECTROPUMP DOES NOT PUMP
WATER, THE MOTOR DOES NOT RUN| 1) No power.| 1) Check the presence of voltage and if the plug is plugged in properly.
2) Motor protection tripped.| 2) Verify the cause and reset the switch. If the thermal circuit breaker has tripped wait for the system to cool down.
3) Defective condenser.| 3) Replace the condenser.
4) Shaft blocked.| 4) Verify the cause and unblock the electropump.
THE MOTOR RUNS BUT THE ELECTROPUMP
DOES NOT PUMP LIQUID| 1) The pump is sucking air.| • Make sure that the joints are airtight.
• Check that the level of liquid has not dropped below the minimum priming level.
2) The pump rotates in the wrong direction| 2) Reset the direction of rotation.
3) Suction grid blocked.| 3) Clean the suction grid.
4) Check valve blocked.| 4) Clean or replace valve.
THE ELECTROPUMP STOPS AFTER RUNNING
FOR A SHORT PERIOD OF TIME BECAUSE
ONE OF THE THERMAL MOTOR CIRCUIT
BREAKER TRIPS| 1) The power supply does not conform with the data on the nameplate.| 1) Check the voltage on the power supply cable leads.
2) A solid object is blocking the impellers.| 2) Take the electropump to an authorised centre so that it can be disassembled and completely cleaned.
3) The liquid is too thick.| 3) Change the type of electropump.

If the problem cannot be eliminated after carrying out the above-described operations contact the closest service centre.

WARRANTY

This device is covered by legal warranty, based on the regulations and standards in force to date and in the country of purchase, as regards manufacturing and/or material defects. The warranty only covers fixing or replacement of the pump or defective parts, at the PENTAIR INTERNATIONAL S.a.r.l. authorized service centers. Components subject to wear, such as mechanical seal and counter face, sealing rings and gaskets, impeller and hydraulic part, membranes and electric cables are guaranteed for a period not exceeding their useful life. For a proper use and life of the product, and to make use of the warranty rights, have these parts inspected and optionally replaced at the authorized service centers, based on their use. To exercise warranty rights, in the event of fault please contact your retailer and/or the authorized service center. Any defects of the product should be reported as soon as the fault is discovered and in any event, within the terms set forth by law. The warranty is valid as of the date of purchase, as proved by the user submitting a purchase receipt, invoice or delivery note. The warranty becomes void: if the failure is caused by improper treatments or operations, incorrect startup or storage, wrong electric or hydraulic connections, failed or inappropriate protection; if the equipment installation or system were not performed correctly; if the failure is due to force majeure or external non- controllable factors; if the product is used with abrasive or corrosive liquids or other than those allowed, or in any event not compatible with the materials used in the pump construction; if the product is used besides the limits reported on the plate or in conditions not allowed and in the event of unauthorized interventions by the user or other personnel for even partial disassembly of the product, changes or tampering; if the materials are naturally worn. Any use differing from that indicated on the use and maintenance manual is not guaranteed, unless otherwise indicated in writing by the manufacturer. Please read the instruction manual carefully before using the product.

Warnings:
If the unit does not work, check whether the failure is due to other reasons, such as power supply failure, control or command equipment or wrong handling. Please enclose the following documents with the faulty equipment: Purchase receipt (invoice slip) Detailed description of the fault found

PENTAIR WATER ITALY S.R.L
VIA MASACCIO 13 | 56010 LUGNANO DI VICOPISANO | PISA – ITALIA
All indicated Pentair trademarks and logos are property of Pentair. Third party registered and unregistered
trademarks and logos are the property of their respective owners.
Because we are continously improving our products and services, Pentair reserves the right to change
specifications without prior notice.
253PA900-01 Rev.4 11/2021 © 2021 Pentair. All Rights Reserved.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Pentair User Manuals

Related Manuals