mr steam MS-90E iTempo Control Instruction Manual
- June 12, 2024
- Mr.Steam
Table of Contents
Installation,
Operation & Maintenance Manual
i TEMPO ® & i TEMPOPLUS® CONTROLS **mr.steam ® Feel Good Inc.
[ www.mrsteam.com**](http://www.mrsteam.com)
When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:
IMPORTANT SAFETY INSTRUCTIONS
-
READ AND FOLLOW ALL INSTRUCTIONS
-
WARNING Supervise children at all times. !
-
Steam is hot and can cause injury or death
WARNING ! if improperly used. Steam rooms contain steam and elevated temperatures. Please read and observe all warnings in this manual before installing or using a steam room. -
To reduce the risk of injury:
WARNING !
A. The wet surfaces of steam enclosures may be slippery. Use care when entering or leaving.
B. The steam head is hot. DO NOT touch the steamhead and avoid the steam near the steamhead.
C. Prolonged use of the steam system can raise excessively the internal human body temperature and impair the body’s ability to regulate its internal temperature (hyperthermia). Limit your use of steam to 10-15 minutes until you are certain of your body’s reaction.
D. Excessive temperatures have a high potential for causing fetal damage during the early months of pregnancy. Pregnancy or possibly pregnant women should consult a physician regarding correct exposure.
E. Obese persons and persons with a history of heart disease, low or high blood pressure, circulatory system problems, or diabetes should consult a physician before using a steambath.
F. Persons using medication should consult a physician before using a steambath since some medication may induce drowsiness while other medications may affect heart rate, blood pressure and circulation.
SAVE THESE INSTRUCTIONS
HYPERTHERMIA occurs when the internal temperature of the body reaches a
level several degrees above the normal body temperature of 98.6°
F. The symptoms of hyperthermia include an increase in the internal
temperature of the body, dizziness, lethargy, drowsiness, and fainting. The
effects of hyperthermia include:
a) Failure to perceive heat;
b) Failure to recognize the need to exit the steambath;
c) Unawareness of impending risk;
d) Fetal damage in pregnant women;
e) Physical inability to exit the steambath; and
f) Unconsciousness.
WARNING!
The use of alcohol, drugs, or medication can greatly increase the risk of
hyperthermia.
READ ME FIRST!
As you follow these instruc-
WARNING ! tions, you will notice warning and caution symbols. This
blocked information is important for the safe and efficient installation and
operation of this generator. These are types of potential hazards that may
occur during installation and operation:
Indicates a potentially
WARNING !
hazardous situation, which, if not avoided, could result in death or serious
injury.
CAUTION
Indicates a potentially !
hazardous situation, which, if not avoided may result in minor or moderate
injury or product damage.
IMPORTANT NOTE: This highlights information that is especially relevant
to a problem-free installation. All information in these instructions is based
on the latest product information available at the time of publication.
Sussman-Automatic Corporation reserves the right to make changes at any time
without notice.
BEFORE INSTALLING
Carefully inspect the control and packaging for shipping damage. In the event
of shipping damage, please contact the carrier for claim information. Our
customer service department can assist you with any missing or damaged parts.
CAUTION To avoid unintentional steambath ! operation, do not locate the
control where other controls, accessories, shower heads, valves, body sprays
or similar within the shower could cause confusion or interfere with the
MrSteam control’s intended use and unction. Do not use any iTempoPlus®,
iTempo® , HomeWizard® or iGenie® controls without reading and understanding
the respective Installation and Operation Manual and MrSteam steam generator
Installation and Operation Manual. Failure to read and understand these
instructions may result in an inoperative or hazardous installation.
A peel and stick warning sticker is provided in the MrSteam steam generator
Installation, Operation and Maintenance Manual. This manual is provided with
every steam generator. The warning sticker must be read and permanently affixed
in a conspicuous ocation near the steam room. Failure to read and affix this
warning sticker in a conspicuous location may result in serious injury or
death.
Please call MrSteam at 800 767-8326 for a free replacement or if you have any
questions regarding the warning sticker.
WARNING !
Install the iTempo or iTempoPlus controls according to installation
instructions. Failure to install according to instructions will result in an
inoperative control or hazardous overheating or inadequate heating of the
steam room.
Failure to install according to instructions will result in an inoperative
control and overheating of the steam room.
IMPORTANT NOTE: If the desired location for the control is outside the
steam room a Remote Temperature Probe (MSTS) must be installed inside the
steam room. Contact MrSteam technical service 1-800-767- 8326 for more
information on the Remote Temperature Probe.
WARNING
Do not route iTempoPlus, iTempo, ! HomeWizard or iGenie control wiring inside
conduit together with power lines or close to hot water or steam piping. Doing
so may result in an inoperative or hazardous installation.
Do not alter or modify any MrSteam
WARNING !
product. Doing so may result in an inoperative or hazardous installation and
will void the warranty.
IMPORTANT NOTES:
- Turn power to the steam generator OFF before connecting the control to the generator. Failure to turn the power off will result in an inoperable control.
- Do not operate iTempoPlus, iTempo, Home Wizard or iGenie controls with anything other than a MrSteam iTempo compatible steam generator. MrSteam residential steam generators with serial numbers lower than 900000, or any other brand of steam generator are not to be operated with iTempo controls. Doing so may result in an inoperative installation.
- This document contains important safety, opera tion and maintenance information. Leave this document with the homeowner. Do not discard this document.
- Discontinue use of the steam generator or control if the steam generator is damaged or otherwise not functioning properly. Doing so may result in an inoperative or hazardous installation.
- All illustrations are for illustrative purposes only.
Dimensional Information for the Round and Square iTempo ® and iTempoPlus®
Box Contents:
- iTempo or iTempoPlus Control
- Control Cable (30 ft.)
- Steam head
- Tube of Silicone sealant
- Owner’s Manual
Installation Instructions for Round & Square iTempo® and iTempoPlus®
IMPORTANT NOTE: If the desired location for the control is outside the
steam room a Remote Temperature Probe (MSTS) must be installed inside the
steam room. Contact MrSteam technical service 1-800-7678326 for more
information on the Remote Temperature Probe.
NOTE: The connector is keyed with the flat facing up. The control cable is
the same at both ends.
STEP 1 Determine the desired installation location of the control. The
iTempo and iTempoPlus controls are designed to be installed inside or outside
the steam room as a matter of personal preference. If the control is installed
inside the steam room the control must be located:
- 4-5 feet above the floor near the bather seating area.
- The control features an integral temperature sensor. Locate the control in a location representative of the desired steam bathing temperatures. Do not locate the control above or near the steam head or direct steam emissions. Locating the controls near the steamhead or near direct steam emissions may result in poor steam room temperature control.
- On a vertical wall
- The control cable length is 30 feet. Insure that the control and/or steam generator are located accordingly. Contact a MrSteam technical service representative if a longer cable is required (60 ft. cable, PN 103990-60).
IMPORTANT NOTE : The control cable should be run in a dedicated 1” conduit to facilitate installation and service. Be careful not to strain, staple, pinch or otherwise damage the control cable. Route cable as required to permit replacement. Do not route cable inside conduit together with power lines or close to hot water or steam piping.
STEP 2 Diagram 1 Make a 25 ⁄8” wide by 37 ⁄8” high cutout in the desired
control location. Do not oversize or under size the cutout. STEP 3 Diagram 2 Route
the control cable (provided with the control) from the wall cutout to the
steam generator. Connect one end of the cable to the steam generator
connector.
NOTE: The connector is keyed with the flat facing up. The control cable is
the same at both ends.
STEP 4 Diagram 3 Firmly connect the other end of the cable to the
control. Turn on power to the steam generator and test the control to verify
correct connections. Test per the instructions on pages 10-15. With
verification of proper control function, proceed to Step 5.
CAUTION !
If the generator is on for more than a few minutes steam will start coming out
of the steamhead. Insure that the steam room is not occupied.
STEP 5 Diagram 4 Remove and discard peel-off paper to expose adhesive
liner.
STEP 6 Diagram 5 Run a bead of silicone (provided) as shown to the
outer edge of the control faceplate, following the contour of the circle or
square shape. Use silicone as required to create a moisture seal.
NOTE: The silicone supplied by MrSteam can be used to meet a variety of
sealing and gasketing. It cures to silicone rubber and adheres to glass, wood,
metal, porcelain, ceramic tile, painted surfaces, many plastics and rubber.
Surfaces must be clean and dry. Apply thin layer of product. Fit together and
support if necessary. Allow excess material to cure, then trim with a sharp
blade. Sealant “skins” in 5 minutes, dries to touch in 1 hour. Fully cures and
bonds in 24 hrs. IMPORTANT NOTE: Do not apply excessive amounts of
silicone. Do not apply silicone to any other parts of the control including
the adhesive gasket. STEP 7 Diagram 6 Insure the mounting surface is clean and
dry as required for good adhesion. Hold the control with the LED display in
the 12 o’clock position and press the control against the wall u ntil the
adhesive sticks
iTempo®Operating Instructions
The iTempo Control features programmable digital temperature control, a fixed
(60) minute duration, ON/OFF and PAUSE. The control can be set at a
temperature range from 80˚F up to 120˚F Set the steam bathing temperature
WARNING ! according to personal preference, however it is highly
recommended to begin steam bathing at a low temperature setting for a very
short duration to gauge comfort and safety levels.
ON/OFF Diagram 1 Press the ON/OFF key to start or stop the flow of
steam. Steam will begin to flow a few minutes after the control is turned ON.
The duration required for the steam room to reach steam bathing temperatures
depends on the steam room construction and steam generator specifications.
Steam may continue to flow for a short time after the control is turned OFF.
PAUSE FEATURE Diagram 2 If a pause in steam flow is desired press the PAUSE
key. The display will flash while the control is in the PAUSE mode. The timer
will continue to countdown while in the PAUSE mode. Steam may continue to flow
for a short time after pause is pressed.
TIMER FEATURE
When the control is turned ON a 60 minute time duration is initiated. The
control will turn off after 60 minutes unless the control is turned off
manually.
MEMORY FEATURE
If the control is turned off manually before 60 minutes then the default
temperature of 110˚F will be used the next time the control is turned on. If
the control times out at 60 minutes (not manually turned off) then the
previous user temperature setting will be used when the steambath is used
again.
SETTING THE TEMPERATURE
Diagram 3 The control is pre-set and will display the temperature setting
of 110˚F (default setting). Use the UP and DOWN keys to change the temperature
setting from 80˚ F to 120˚ F in one degree increments.
CHANGING THE TEMPERATURE UNITS (F˚/C˚) Diagram 4 Drawings for Illustrative
Purposes Only.
When the generator is Off, Press and hold ON/ OFF key for 10 seconds. The
temperature units will be displayed as Fahrenheit (TuF) or Celsius (TuC). Use
the UP/DOWN keys to choose between (TuF) and (TuC). Press ON/OFF key to accept
the new units and exit.
The iTempoPlus Control features programmable temperature control, programmable
time duration, clock, AromaSteam, ChromaSteam ® , ON/OFF and two personal
settings. Set the steam bathing temperature
WARNING ! according to personal preference, however it is highly
recommended to begin steam bathing at a low temperature setting for a very
short duration to gauge comfort and safety levels.
POWERING UP THE UNIT Diagram 1 When the generator is first powered up or
after a power interruption, the clock display flashes and the clock is ready to
be set up.
NOTE: Pressing the ON/OFF will start the generator even if the clock has
not been set.
NOTE: The clock can only be set when the generator is OFF, the display is
flashing.
SETTING THE CLOCK
ON/OFF Diagram 2 Press the ON/OFF key to start or stop the flow of steam.
The Temperature Set Point is displayed. Steam will begin to flow a few minutes
after the control is turned ON. The duration required for the steam room to
reach steam bathing temperatures depends on the steam room construction and
steam generator specifications. Steam may continue to flow for a short time
after the control is turned OFF.
SETTING THE CLOCK Diagram 3
When the display is not flashing: Press and hold the TIME key until the
display starts flashing. Use the UP/DOWN keys to select the desired time, at
this time the AM/PM logo will be displayed. Press the TIME key to save
changes.
SETTING THE STEAMBATH DURATION
Diagram 4Press TIME key to set or display the steambath
duration time on the clock. The control is pre-set and will display a TIME
setting of 20 minutes (default setting). With the TIME or CLOCK displayed,
press the UP or DOWN keys (Diagram 5) to set the desired duration time (2-60
minutes) in two minute increments.
Set the steambath duration according to personal preference, however it is
highly recommended to begin steam bathing at a very short duration to gauge
comfort and safety levels. The control will turn off when the duration period
times out. Then, the clock time will be displayed.
SETTING THE TEMPERATURE
Diagram 6: Press TEMP key to set the desired temperature or display the
temperature setting. Diagram 7: The control is preset and will display a
temperature setting of 110˚F (default setting). With the temperature
displayed, press the UP or DOWN keys to set the desired temperature (80°F to
120°F) in one degree increments. Set the steam bathing temperature according
to personal preference, however it is highly recommended to begin steam
bathing at a low temperature setting to gauge comfort and safety levels.
MEMORY FEATURE
If the control is turned off manually before it times out then the default
settings of 20 minutes and 110°F will be used the next time the control is
turned on. If the control times out (not manually turned off) then the
previous user time and temperature settings will be used when the steambath is
turned on.
PERSONAL SETTINGS Diagram 8 Use the program key to store preferred
settings.
To program preferred settings:
Press ON/OFF key to turn generator on. Press the Program key once to program
Pr 1. Press it twice to program Pr 2. The selected parameter will be
displayed. Enter the preferred time and temperature settings.
The iTempoPlus will store the following settings: set point, time duration &
aroma state. To select Pr 1 or Pr 2: Press ON/OFF key then press the Program
key once to select Pr 1, press it twice to select Pr 2. The steambath will
begin to operate at the stored settings.
CHANGING THE TEMPERATURE UNITS
(˚F/˚C)
When the generator is Off, Press and hold ON/OFF key for 10 seconds. The
temperature units will be displayed as Fahrenheit (TuF) or Celsius (TuC). Use
the UP/DOWN keys to choose between (TuF) and (TuC). Press ON/OFF key to accept
the new value and exit.
AROMASTEAM Diagram 9 The AromaSteam is an optional accessory that
automatically injects aromatic oil into the steam. Press the ON/OFF key to
turn the steam genera tor on. Then, press the AROMA key. The Aroma indicator
will be displayed. The AromaSteam turns off automatically when the steam
generator stops heating. Press the AROMA key to turn it off during a steam
session. The indicator will turn off.
CHROMASTEAM®
Diagram 10The
ChromaSteam is an optional accessory that provides colored light in the steam
room. Press the CHROMA key to turn light on. Press twice to select the next
color. Press again to turn the light off. Note that the light can be turned ON
even if the steam generator is OFF.
Care Tips for all Controls and Steamheads
- Use only mild soap and water on a soft cloth to clean the control and steamhead.
- Do not use abrasive cleansers
- If the decorative cover is damaged on the iTempo ® or iTempoPlus ® call MrSteam technical service for replacement parts.
NOTE: Replacement of the decorative covers requires removal and reinstallation of the control from the mounting surfaces.
Warranty
To register your steam generator unit online and to review the MrSteam Limited
Lifetime Warranty please go to: blog.mrsteam.com/wr
TEMPLATE FOR CONTROL INSTALLATION (SEE PG.7)
mr.steam®Feel Good Inc.
Products, information and specifications are subject to change without notice.
For more information call Sales & Support at:
1.800.76.STEAM (East Coast) 1.800.72.STEAM (West Coast)
2019 © Sussman-Automatic Corporation MrSteam and des., AromaFlo, AutoFlush,
AutoSteam, Butler Package,
ChromaSteam, Clean Steam…Every Time, Club Therapy, Digital 1, Express Steam,
From Bathroom to Spa, iDream Package, iGenie, iSizing, iSteam,
MusicTherapy, Spa Package, Steam@Home, Steam Therapy, Sussman, Valet Package,
Virtual
Spa System, Voice Genie and Voice Wizard are registered trademarks of Sussman-
Automatic Corporation. AudioWizard,
HomeWizard, iButler, iTempo, iTempoPlus, Smart Sizing, SteamStart, The
Intelligent Steambath are trademarks of
Sussman-Automatic Corporation.
PUR 100474 REV 10.19