Sinclair SP-45AN Air Purifier User Guide

June 12, 2024
Sinclair

Sinclair SP-45AN Air Purifier User Guide
Air Purifier

Quick start guide

What to do with dirty air?
Use negative ion function. Press “Ionizer” button to switch on/off the function. Press “speed/ Mode” button to adjust the speed of fan.
negative ion function
What to do when you are away?
Use kid lock function. You don’t need to worry about safety risk caused by kid’s mis-operation when they left alone
negative ion function

How to use in office and public place?

Use AUTO function. Air purifier will automatically work based on the actual indoor air quality level. Press SPEED button, you can set at AUTO, SPEED 1, SPEED 2, SPEED 3, SLEEP or TURBO mode.

How to use when sleep?
Press SPEED button, select SLEEP function. Air purifier will work under mute, without
light. Press SPEED again, exit from SLEEP

Timer
When power on, press TIMER, it will switch off after 1, 2, 4, 8 hours later.
Negative ion function
Air quality indicator:

Air quality level LED color
Critical Red
Warning Blue
Good Green

Safety instructions

Thank you for choosing EuropAce product! For a better understanding of product usage and functions, safety precautions and product maintaining, please read and follow the user manual carefully, especially content with symbols.

Content with this symbol must be followed for safety reasons in order to avoid damage to product and harm to humans.

Content with this symbol must be followed for product safe usage in order to avoid malfunctioning and harm to humans.

_ Please don’t spray any painting, pesticide, alcohol and any chemical on the unit. Otherwise it will cause crack on unit, risk of shock and fire hazard
If any chemical placed inside of the unit, it will release to air from air outlet. It may be harmful to your healthy. After used pesticide in the room, please don’t use the unit before change of air in the room.
Don’t use the unit in flammable and corrosive environment.
When the unit is working, please don’t touch air inlet and outlet. Don’t insert your hands or other objects into the air inlet and outlet to prevent from hurt or damage the unit.
To prevent from any accident and harm, don’t sit on the place any object on the unit
Please don’t use the unit in bathroon or wet places. It may cause fire hazard and risk of shock.
****_Don’t improperly modify, disassembly, repair the unit. It ay cause fire hazard and risk of shock.

Please don’t use if the cable and plug is broken. Don’t touch with wet hand. It may cause fire hazard and risk of shock
Switch it off and unplug it when move the unit, undergo maintenance
Unplug the unit when not use for long time
Stop using the product if you found odor in the unit, contact after-sales service.
Before use, please check if there are objects drop inside the unit
Place the unit 50mm away from the the wall or obstacle.
If the cable is damaged, to prevent any risks, only service staff and professionals are allowed to replace it.

Introduction

Purification system

This product has multi-stage filtration system. It can be effectively remove haze, dust, dander, hair, pollen, smoke and other floating particles, it also removes formaldehyde, benzene, ammonia, VOCs, nocotine and other odors. It effectively elimilate germs, virus.
Hepa filter can elimilate multi pollutants, such as haze, smut, smoke, pollen. Nano silver coated on HEPA filter can quickly kill bacteria, virus, mold, mites.
Active carbon filter use high-effective coconut shell activated carbon, effectly remove formaldehyde, benzene, ammonia, vocs and other odors.
Negative ionizer will release ions to refresh the indoor air.

Product features

  • Advanced feature; able to adjust according to surrounding temperature, and regulates air to an ideal environment for people.
  • Quiet operation design, guarantees undisturbed sleep.

Product Structure
Product Structure

Operation Guide

Control panel
Negative ion function

  • Refer to next page for its button functions.
  1. Power on/off
    Press the “Power” button to turn on/off the unit.

  2. Filter time counter

    • When power is on, the air purifier starts to count the life of filters – it will continue to count with every power on from where it was left off. After reaching 2000 hours, the Reset LED will flash to indicate that a replacement is needed.
    • Press “Reset” button for 3 seconds, after ‘beep’ sound, LED will off. After filter is replaced – Press “Reset” button for 5 seconds, after 3 ‘beep’ sound, LED will off and time counter will restart on the new filter.
  3. Negative Ion
    When power is on, press “Ionizer” button, the ionizing function will start, LED will on.
    Press button again to switch off.

  4. Timer

    • When power is on, press “Timer” button to enable purifier to switch off at
    • designated time. Timer range activate in an order: [ OFF ]
  5. Speed setting
    When power is on, press “Speed/Mode” button to set a speed from 6 selection. Speed range activate in an order: [ 1 2 3 Sleep Turbo Auto ] Speed
setting

  6. Kid-lock function
    When power is on, press “Reset” + “Speed/Mode” buttons at the same time for 3 seconds to activate lock function. LED at power button will flash every 0.5 seconds, at this time any other buttons will not work.
    Press “Reset” + “Speed/Mode” buttons at the same time again for 3 seconds to remove lock function. LED will return to normal and buttons will work.

Maintenance Guide

  1. This product is not recommended to placed on uneven surface to avoid vibration, noise during working and prevent risk of shock.

  2. To prevent damage, do not put any objects inside the unit.
    Maintenance Guide

  3. When not in use for an extended period, unplug it and keep away from children.

  4. To achieve better purification results, place product in an open area, refrain from blocking air inlet and outlet of unit.Maintenance Guide

  5. Please switch off the unit and unplug when undergoing maintenance, checks and moving the unit.

  6. HEPA filter and active carbon filter need to be replaced after been expired. Please purchase from an authorised dealer.

Maintaining notes

To extend the life of unit, please regularly undergo maintenance. Before maintenance, please switch off the unit and unplug it. After use, if the filters need to be replaced, the filter change indicator on the control panel flashes. It reminds of user to replace with a new filter. HEPA filter and active carbon filter need to be replaced at the same time.

Cleaning instructions

  1. External clean
    • Before clean the external of the unit, please cut off the power.
    • Use soft and clean cloth.
    • Do not use alcohol, gasoline, benzol and other chemical cleaner.
  2. Removal of PE bag
    Before first time use, please open the front panel, take out the filters and remove its PE bag wrap – or the unit will not be able to purify the air.

Removal of PE bag

  1. Clean / replace filters
    Please follow the pictures on the filter below to correctly install the filter:

  2. As shown in diagram A below:

    hold both upper sides of the unit, pull out the front panel and lift it.
    Note: The black sponge used in front of the HEPA filter can be washed with water and can be re-used after dry. It is recommended to wash it every 3 months to extend the life of HEPA filter.

  3. **As shown in diagram B:

** pull down the strap on the filter to take out HEPA filter.

3.  **As shown in diagram C:  

** pull down the strap on the filter to take out carbon filter.

4. Please hold the middle part of the front panel with both hands to install it as shown in **diagram** **D  

**

Reminder: HEPA and carbon filters cannot be washed with water.

Troubleshooting & Solution

Malfunction Check point Solution
Failure to power on Check if switch is on Switch unit on
Check if plug is loose Correctly plug it to power source
Check if front panel is correctly installed Correctly install panel to unit
Unit operating sound very low and weak air output Check if PE bag was
removed Remove the PE bag and install the filters in correct order
Check if air outlet is blocked Switch off unit and remove any obstruction
Air outlet has an odor Check if there are objects with odor placed near
unit’s air inlet Remove those odor-causing objects
Check if the filters need to be replaced Replace filters for the unit

__Caution

  • Use voltage only at 230V 50Hz. Otherwise it may cause fire hazard and risk of shock.
  • Do not improperly bend, pull, twist, tie the power cable or place it near the high temperature. Damage of the cable may cause fire and risk of shock.
  • Do not use put any heavy object on it or clip it.
  • If the cable or plug is broken and remains loose when plugged into the socket, please do not use it.
  • Do not touch the plug with wet hands.
  • Please do not replace or change the cable. If broken, please contact service hotline.
  • Please clean away any dust or dirt on the plug and cable regularly

Specifications

P roduct Air purifier SINCLAIR
Model SP-45AN
Power input 220-240 V~ / 50 Hz
Rated power input 80 W
Noise level Max 55 dB(A)
Optimal room size do 45 m2
CADR 340 m3/h / 205 CFM
Temperature/Humidity applied 0 – 40 °C / 20 – 90 %
Dimensions 374 × 594 × 201 mm
Weight netto/bruto 6,8 / 8,5 kg

Replacement filters: SPF-45N

Contacts

PRODUCER
SINCLAIR CORPORATION Ltd.
1-4 Argyll St.
LONDON
W1F 7LD
United Kingdom
www.sinclair-world.com
The device was made in China (Made in China).
REPRESENTATIVE, SERVICE
SINCLAIR Global Group s.r.o.
Purkyňova 45
Brno
612 00
Czech republic
Phone – service: +420 541 590 150
Phone – sales: +420 541 590 140
Fax: +420 541 590 124
[email protected]
www.sinclair-solutions.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Sinclair User Manuals

Related Manuals