euromate 482274 Local Air Conditioner Unit Instruction Manual

June 12, 2024
euromate

euromate-logo

euromate 482274 Local Air Conditioner Unit

euromate-482274-Local-Air-Conditioner-Unit-product

Product Information

This product is a standing air conditioner, suitable for local climate control. It has a material number of 482274 or 482282 and operates on a voltage of 230V~ with a frequency of 50Hz. The rated power is 2900W and it has a net weight of 28kg. The air conditioner is designed for indoor use and has a protection class of I and a protection rating of IPX0. The product comes with a remote control and uses R290 as the refrigerant.

Product Usage Instructions

  1. Assembly:
  2. Refer to the manual for the components included in the package.
  3. Follow the instructions for assembly, including the installation of the window kit.
  4. Operation:
  5. Use the power switch (A) to turn the air conditioner on or off.
  6. Adjust the temperature using the temperature up (C) and temperature down (D) buttons.
  7. Select the desired operating mode using the mode button (E).
  8. Use the timer button (F) to set the timer for automatic operation.
  9. Turn on or off the swing function using the swing button (G).
  10. Activate the sleep mode using the sleep button (H).
  11. Maintenance:
  12. Clean the air filter every two weeks to remove dust and dirt.
  13. Refer to the manual for instructions on how to clean and maintain the air conditioner.
  14. Troubleshooting:
  15. If the air conditioner is not functioning properly, refer to the troubleshooting section of the manual for possible solutions.
  16. Disposal:
  17. Dispose of the packaging material properly.
  18. Refer to local regulations for proper disposal of the air conditioner at the end of its life cycle.

Before you begin

Intended use

  • The device is designed only for non-commercial use as a portable air conditioning unit.
  • The device may only be used in dry indoor areas
  • within a specified temperature range (► Operating conditions – p. 35).
  • This product is not intended for commercial use. Generally acknowledged accident prevention regulations and enclosed safety instructions must be observed.
  • Only perform the work described in these instructions for use. Any other use is improper. The manufacturer will not assume responsibility for damage resulting from such use.

What are the meanings of the symbols used?
Danger notices and information are clearly marked throughout these instructions for use. The following symbols are used:

  • DANGER! Direct danger to life and risk of injury! Directly dangerous situations that may lead to death or severe injuries.
  • WARNING! Probable danger to life and risk of injury! Generally dangerous situations that may lead to death or severe injuries.
  • CAUTION! Possible risk of injury! A dangerous situation that may lead to injuries.
  • NOTICE! Risk of damage to the device! The situation may lead to property damage.
  • Note: Information to help you reach a better understanding of the processes involved.

For your safety

General safety instructions

  • To operate this device safely, the user must have read and understood these instructions for use before using the device for the first time.
  • Observe all safety instructions! Failure to do so may cause harm to you and others.
  • Retain all instructions for use, and safety instructions for future reference.
  • If you sell or pass the device on, you must also hand over these operating instructions.
  • The device must only be used when it functions properly. If the product or part of the product is defective, it must be taken out of operation and disposed of correctly.
  • Never use the device in a room where there is a danger of explosion or in the vicinity of flammable liquids or gases.
  • Always ensure that a device that has been switched off cannot be restarted unintentionally.
  • Do not use devices with an on/off switch that does not function correctly.
  • Keep children away from the device! Keep the device out of the way of children and other unauthorized persons.
  • Do not overload the device. Do not use the device for purposes for which it is not intended.
  • Exercise caution and only work when in good condition: If you are tired, or ill, if you have ingested alcohol, medication or illegal drugs, do not use the device, as you are not in a condition to use it safely.
  • This product is not intended to be used by persons (including children) who are limited in their physical, sensory or mental capacities or who lack experience and/or knowledge of the product unless they are supervised, or have been instructed on how to use the product, by a person responsible for their safety.
  • Ensure that children are not able to play with the device.
  • Always comply with all applicable domestic and international safety, health, and working regulations.

Electrical safety

  • The device may only be connected to a socket that is correctly installed and grounded.
  • The fuse must be a residual current circuit breaker with a measured residual current of no more than 30 mA.
  • Make sure that the power supply corresponds with the connection specifications of the device before it is connected.
  • The tool may only be used within the specified limitations for voltage and power (see type plate).
  • Do not touch the mains plug with wet hands! Always pull out the mains plug at the plug and not by the cable.
  • Do not bend, crush, pull or drive over the power cable, protect from sharp edges, oil, and heat.
  • Do not lift the device using the cable or use the cable for purposes other than intended.
  • Check the plug and cable before each use.
  • If the power cable is damaged immediately disconnect the plug. Never use the device if the power cable is damaged.
  • If the device is not in use make sure the plug is pulled out.
  • Make sure that the device is switched off before plugging in the main cable.
  • Make sure that the device is switched off before unplugging it.
  • Disconnect the power supply before transporting the device.

Using battery-operated devices

  • Only use batteries approved by the manufacturer.
  • The danger of fire! Never charge the batteries.
  • Keep batteries away from metal objects that could cause short-circuiting when not in use. There is a risk of injuries and fires.
  • Fluid can escape from the battery when used incorrectly. Battery fluid may result in skin irritations and burns. Avoid contact! In the event of accidental contact, rinse thoroughly with water. Immediately seek the aid of a physician in the event of eye contact.

Device-specific safety instructions

  • Do not store or set the device up in locations where it may fall down or become submerged in water.
  • Always transport the device in an upright position and place it on a stable and horizontal surface to use.
  • Switch the device off when it is not in use.
  • Ensure a minimum distance of 30 cm is maintained with free air circulation to walls, furniture, and curtains.
  • If the air conditioning unit is tipped over during operation, it must be switched off immediately and separated from the power supply.
  • Always use the switch on the operating panel.
  • Do not use the air conditioning units in rooms with high air humidity, for example, bathrooms or laundry rooms.
  • Do not touch the device with wet hands or when barefoot.
  • Only touch the buttons on the control panel with your fingers.
  • Do not remove any of the fixed covers.
  • Never use the device when it is not in perfect working order or when it has been dropped or damaged.
  • Never switch the device on or off using the wall plug.
  • Do not cover the inlet or outlet meshes or block them in any other way.
  • Do not use dangerous chemicals to clean the device or bring such into contact with it.
  • Do not store or use petrol or other flammable vapors or liquids in the vicinity of this or other devices.
  • Avoid fire or electric shock risks. Do not use extension cords or adapter plugs. Do not remove poles from the main cable.
  • Check whether the power supply is suitable for the selected model. The appropriate information can be found on the type plate of the device on the side behind the mesh.
  • Ensure that the device is correctly earthed. Correct earthing is particularly important in order to minimize electrical shock and fire risks. The mains cable is fitted with a three-pole grounded plug for protection against electric shocks.
  • The device must be operated and connected to a correctly earthed mains socket. If the mains socket selected for operation is not correctly earthed or fitted with a slow-blow fuse or a protective switched, an appropriate mains socket must be installed by a qualified electrician.
  • The main socket must also be accessible after the device has been set up.
  • Remember that moving parts may also be located behind ventilation and venting slots.
  • If the power cable of this device is damaged, it may only be replaced by the manufacturer, their customer service operation, or a similarly qualified person, in order to prevent risks.
  • Symbols affixed to your device may not be removed or covered. Information on the device that is no longer legible must be replaced immediately.
  • Do not use the device if there are flammable substances or vapours in the vicinity, such as alcohol, insecticides, or petroleum.
    • Prior to using the device, read and follow the operating instructions.
    • The appliance contains refrigerant R290. Risk of fire.
    • Note: This device may be used by children as of the age of eight (8) and by persons with limited physical, sensory or mental capabilities or lack of experience and/or knowledge if they are supervised or have been instructed in the safe operation of the device and understanding the risks resulting from this. Children may not play with the device. Cleaning and user maintenance may not be carried out by children unless supervised.
    • DANGER! Risk of death through electric shock! The use of this variant outside Switzerland is not permissible for safety reasons, as this poses a risk of electric shock or fire.
  • The variant of the product sold in Switzerland may only be used in Switzerland, as it is equipped with a Swiss plug.
  • You can identify the variant by means of the item number on the product (the instructions always contain all item numbers):
    • Item number Switzerland: 482282
    • Item number in other EU countries: 482274

The specific information of refrigerant gas R290 of this appliance

  • When defrosting and cleaning the appliance, do not use any tools other than those recommended by the manufacturing company.
  • The appliance must be placed in an area without any continuous sources of ignition (for example open flames, gas or electrical appliances in operation).
  • Do not puncture and do not burn.
  • This appliance contains 212 g (see rating label of the unit) of R290 refrigerant gas.
  • R290 is a refrigerant gas that complies with European directives on the environment. Do not puncture any part of the refrigerant circuit.

If the appliance is installed, operated, or stored in an unventilated area, the room must be designed to prevent to the accumulation of refrigerant leaks resulting in a risk of fire or explosion due to ignition of the refrigerant caused by electric heaters, stoves, or other sources of ignition.

  • The appliance must be stored in such a way as to prevent mechanical failure.
  • Individuals who operate or work on the refrigerant circuit must have the appropriate certification issued by an accredited organization that ensures competence in handling refrigerants according to a specific evaluation recognized by associations in the industry.
  • Repairs must be performed based on the recommendation from the manufacturing company. Maintenance and repairs that require the assistance of other qualified personnel must be performed under the supervision of an individual specified in the use of flammable refrigerants.

Energy saving

  • Use the device in rooms of the recommended size.
  • Set the device up in such a way that the airflow is not obstructed by furniture.
  • Keeps blinds/curtains closed in the event of strong sunlight.
  • Keep filters clean.
  • Keep doors and windows close in order to keep cool air in warm air out (when cooling) or to keep warm air in and cold air out (when heating).

Operating conditions
The air conditioning unit may only be operated within the temperature range detailed below:

Operating mode/DB/WB(°C)

  • Maximum cooling 35/24
  • Minimum cooling 18/12

Scope of delivery

Note:
All figures in this manual are designed for explanation purposes only. Your air conditioning unit may look slightly different. The actual shape is key.

  • A. Exhaust hose
  • B. Housing adaptor
  • C. Window Connector
  • D. Remote Controller
  • E. Window Kiteuromate-482274-Local-Air-Conditioner-Unit-fig- \(1\)

Your device at a glance

  1. Louver
  2. Control panel
  3. Front panel
  4. Castor
  5. Air inlet
  6. Drainage outlet
  7. Air outlet
  8. Power cord
  9. Drainage outleteuromate-482274-Local-Air-Conditioner-Unit-fig- \(2\)

Assembly

Set up

  • In order to minimize noise and vibrations, the air conditioning unit should be set up on a solid surface. In order to set up the unit safely, position it on a smooth, even surface that is stable enough to carry the weight of the unit.
  • The device is fitted with castors in order to ensure it is easy to set up. It should only be rolled on smooth, flat surfaces. Take care when rolling over carpets. Do not attempt to roll the device over objects.
  • The device be set up within the range of a correctly earthed mains socket with the appropriate nominal voltage.
  • Never bring obstacles into the air inlet or outlet areas.
  • In order to ensure efficient conditioning operation, set the device up with a minimum distance of 30 cm to the wall.
  • Ensure that the window feed-through gives a free throughway to the outdoors. Close the window or door as much as possible.

Introduction to Exhaust Hose Installation Temporary installation item 2

  • Twist the housing adaptor and the window Connector to the ends of the exhaust hose. item 3
  • Insert the fixing clip of the housing adaptor into the openings at the back of the air conditioner. item 4
  • Put the other end of the exhaust hose the near windowsill.

Window Slider Kit Installation item 5

  • The installation manner of window slider kit is mostly in “horizontal” or “vertical”. As shown, check the min. and max. size of the window before the installation. item 7
  • Install the window kit on the window;
  • Adjust the length of the window slider kit accord-ing to the window width or height, and fix it with the dowel;
  • Insert the window connector of the hose to the hole of the window kit.

Universal caulking kit accessory for mobile air conditioner item 10

Included in this kit: item 11

  • 1 piece of fabric
  • 1 roll of tape gripping adhesive item 12
  • Open the window and clean the doors and frame before gluing the adhesive tape. item 13
  • Cut large strips of adhesive gripping tape to the dimensions of the window.
  • Glue them to the frame of your window and then do the same on the inner surface of the window flap (on the side of the handle). item 14
  • Glue the widest side (A) of the large white fabric piece to the window frame and then glue the nar-rower side (B) to the window leaf (handle side) from the center, then up and finally down.
  • Close the window and make sure the large fabric piece is not stuck in the closing seams and the window closes always correctly, even with the tapes sticky adhesive tape. item 15
  • Open the window gently and open the zipper of the fabric piece (at level of the bottom or middle of the window) then insert the exhaust duct into the opening.
  • Readjust the zipper so that the exhaust duct is attached so that there is no air exchange between the inside and the outside. item 16
  • Your caulking kit is now installed, you can now turn on and enjoy the coolness of your mobile air conditioner!
  • If you no longer want to use your mobile air con-ditioner and close your window, you can simply remove the sheath from the zipper and close your window, in verifying that the fabric piece is not stuck in the closing seals.

euromate-482274-Local-Air-Conditioner-Unit-fig- \(3\) euromate-482274-Local-Air-Conditioner-Unit-fig-
\(4\) euromate-482274-Local-Air-Conditioner-Unit-
fig- \(5\)

Note:
If you have a window with French opening with two leaves: Block the first leaf with the handle and make the installation of the caulking kit on the second leaf (without the handle). Before installation, check that the adhesive gripping tape do not damage your window.

Operation

Before use, familiarise yourself thoroughly with the operating panel and the remote control as well as their functions. You can then use the icons as orien-tation for the desired functions. The device can be operated via the operating panel on the device or using the remote control.

The operating panel of the air conditioning unit

  • A. Power on/off
  • B. Fan speed
  • C. Temperature up
  • D. Temperature down
  • E. Operation mode
  • F. Timer on/off
  • G. Swing on/off
  • H. Sleep mode
  • 1. Cooling
  • 2. Dehumidifying
  • 3. Fan
  • 4. WIFI
  • 5. High fan speed
  • 6. Medium fan speed
  • 7. Low fan speed
  • 8. Water fulleuromate-482274-Local-Air-Conditioner-Unit-fig- \(6\)
Remote control
  1. [POWER]: Power on/off
  2. [TIMER]: Timer on/off
  3. [MODE]: Operation MODE
  4. [TEMP-]: Temperature down
  5. [TEMP+]: Temperature up
  6. [SPEED]: Fan speed
  7. [Sleep]: Sleep mode
  8. [SWING]: Auto swing

Note:
Do not drop the remote controller. Do not place the remote controller in a location exposed to direct sunlight.

Operation Introduction
Before starting operations in this section:

  • Find a place where there is power supply nearby. item 3
  • As shown, install the exhaust hose, and adjust the window position well. item 4
  • Connect drain hose well (only for using heating model);
  • Insert the power cord into an grounded AC220~240V/50Hz socket;
  • Press the [POWER] button to turn on the air-con-ditioner.euromate-482274-Local-Air-Conditioner-Unit-fig- \(9\)

Cooling operation

  •  Press the [Mode] button till the [Cool] icon appears.
  • Press the [DOWN]or [UP] button to select a desired room temperature. (16°C-31°C)
  • Press the [WIND] button to select wind speed.

Dehumidifying operation

  • Press the [Mode] button till the [Dehumidify] icon appears.
  • Automatically set the selected temperature to cur-rent room temperature minus 2°C. (16°C-31°C)
  • Automatically set the fan motor to [LOW] wind speed.

Fan operation

  • Press the [Mode] button till the [Fan] icon appears.
  • Press the [WIND] button to select wind speed. Timer operation

Timer [ON] setting:

  • When the air-conditioner is [OFF], press the [Timer] button and select a desired [ON] time through the temperature and time setting buttons.
  • [Preset ON Time] is displayed on the operation panel.
  • [ON] time can be regulated at any time in 0-24 hours.
  • Press the [Timer] button again to confirm, Timer indicator turns on.
  • To deactivate the timer function, press [Timer] button until timer indicator turns off. Timer [OFF] setting
  • When the air-conditioner [ON], press [Timer] button and select a desired [OFF] time through the temperature and time setting buttons.
  • [Preset OFF Time] is displayed on the operation panel.
  • [OFF] time can be regulated at any time in 0-24 hours.
  • Press the [Timer] button again to confirm, Timer indicator turns on.
  • To deactivate the timer function, press [Timer] button until timer indicator turns off.

Auto [SWING] After machine turns on, press this key, the louver will swing continuously up and down; by pressing this button again the movement will stop and the louver remain in that position.

[SLEEP] mode

  • While in cooling mode, press the [SLEEP] key to set the temperature. It increases 1 °C after an hour and at most increases 2 °C after 2 hours.
  • While in heating mode, press the [SLEEP] key to set the temperature. It decreases 1 °C after an hour and at most decreases 2 °C after 2 hours.
  • Press the [SLEEP] key again can cancel the set-ting.

Water drainage

Water Full Alarm

The inner water tray in the air-conditioner has one water level safety switches, it controls the water level. When water level reaches an anticipated height, the water full indicator lights up. When the water is full, please remove the rubber blockage from the drain-age outlet at the bottom of unit, and drain all water outside.

Continuous Drainage

  • When you plan to leave this unit unused for a long time, please remove the rubber blockage from the drainage hole at the bottom of unit, and drain all water outside.
  • You can use the continuous drainage with a drainage hose connected to the bottom drain hole, when the unit working at the [HEAT] mode.
  • The continuous drainage is not need to be applied when the unit working at the [COOL] or [DEHUMID-IFY] mode. The unit can evaporate the condensate water automatically by the splash motor. Make sure the drainage holes are stemmed well.
  • If water splash motor is damaged, continuous drain-age can be used. To connect the drain hose to the bottom drainage outlet, the unit can also work well.
  • If splash motor is damaged, intermittent drainage can also be used. Under this condition, when the water full indicator lights up, please connect a drain hose to the bottom drainage hole, then all the water in the water tank will be drained outside. The unit can also work well.

[WIFI] function (for some models)

  • Long press the [SLEEP] button for 5s, enter the [WIFI] factory set up mode;

  • The unit is connected with WIFI If the [WIFI] indi-cator is on, other wise is not connected. When the [WIFI] indicator flashing slowly, the unit is at the [WIFI] set up mode, if flashing quickly, the unit is connected with WIFI;

  • You can realize all the air conditioner functions by the mobile phone APP with the WIFI connected.

Insert/replace batteries

  • To insert the batteries, push back the lid of the battery compartment and insert the batteries. Please ensure that you insert the batteries the right way around (+/-).
  • In order to replace old batteries, use the same procedure as above.
  • When replacing the batteries to not use old or dif-ferent batteries. This can lead to a fault in the remote control.
  • If you do not use the remote control for several weeks, take out the batteries. Leaking batteries can cause damage in the remote control.
  • In normal use, the average battery service life is approximately 6 months.
  • Replace the batteries if the indoor appliance does not respond with a beep tone or if the transmis-sion indicator light no longer lights up.
  • Do not place heavy objects or other loads on the ventilation opening, this may damage the unit.

Care and maintenance

  • DANGER! Risk to life! Always separate the device from the power supply before car-rying out cleaning or maintenance work.
  • DANGER! Risk to life! Never wash the device directly under a tap or using a hose. This may create a risk of electric shock.
  • NOTICE! Risk of damage to the device! Do not use petrol, thinner or other chemicals to clean the device.

Water Full alarm

  • The inner water tray inside the air-conditioner has one water level safety switches, it controls water level. When water level reaches an anticipated height, the water full indicator lights up. (If water splash motor is damaged, when the water is full, please remove the rubber blockage at the bottom of unit, and all water will be drained outside.)
    Air Filter

  • If the air filter becomes clogged with dust/dirt, the air filter should be cleaned once every two weeks.

  • Dismounting: Open the air inlet grille and take off air filter.

  • Cleaning: Clean the air filter with neural detergent in lukewarm (40°C) and dry it up in the shade.

  • Mounting: Putting the air filter into the inlet grille, replace the components as they were.euromate-482274-Local-Air-Conditioner-Unit-fig- \(10\) euromate-482274-Local-Air-Conditioner-Unit-fig- \(11\)

Clean the Air-conditioner Surface
First clean the surface with a neutral detergent and wet cloth, and then wipe it with a dry cloth.

Solving problems

What to do when something no longer works

DANGER! Risk to life!
Unprofessionally carried out repairs may mean that the prod-uct will no longer operate safely. This is a risk for you and your environment.

Faulty functions are often caused by small errors. You will be able to deal with many of these yourself. Pay attention to the following table before you contact OBI. This may save you unnecessary trouble and possibly also costs.

Error/Faulty function Cause Remedy
Unit does not start when pressing Water full indicator lamp blinks, and Dump

the water out of the water
on/off button| water tray is full.| tray.
 | Room temperature is higher than the setting temperature. (Electric heating mode)| Reset the temperature
 | Room temperature is lower than the setting temperature. (Cooling mode)|
Not cool enough| The doors or windows are not closed.| Make sure all the windows and doors are closed.
 | There are heat sources inside the room.| Remove the heat sources if possible
 | Exhaust air hose is not connected or blocked.| Connect or clean the exhaust air hose.
 | Temperature setting is too high.| Reset the temperature
 | Air inlet is blocked.| Clean the air inlet.
Noisy| The ground is not level or not flat enough| Place the unit on a flat, level ground if possible
 | The sound comes from the flowing of the refrigerant inside the air con- ditioner| It is normal.
[E0] Code| Room temperature sensor failed| Replace room temperature sensor (the unit can also work without re- placement.)
[E1] Code| Condenser temperature sensor failed| Replace condenser temperature sensor
[E2] Code| Water tray full when cooling| Take off rubber stopper and empty the water.
[E3] Code| Evaporator temperature sensor failed| Replace evaporator temperature sensor
[E4] Code| Water tray full when heating| Please empty the water tray.

If you are unable to eliminate the error yourself, please contact your closest OBI market. Please note that unprofessional repairs will void your guarantee and may lead to additional costs above and beyond the guarantee.

Disposal

Disposal of the appliance

  • A crossed-out wheelie bin icon means: Bat- teries and rechargeable batteries, electrical or electronic devices must not be disposed of with household waste. They may contain substances that are harmful to the environment and human health.
  • Consumers must dispose of waste electrical devices, spent portable batteries and rechargeable batteries separately from household waste at an official collection point to ensure that these items are processed correctly. Information on returning these items is available from the seller. Sellers are required to accept these items free of charge.
  • Batteries, rechargeable batteries and lamps that are not permanently installed in waste electrical equipment and can be removed in a non-destructive way must be removed and disposed of separately before disposal of the equip-ment.
  • Lithium batteries and battery packs in all sys-tems must only be retuned to a collection point when discharged. Batteries must always be protected against short circuits by covering the poles with adhe-sive tape.
  • All end users are responsible for deleting any per-sonal data stored on waste devices prior to their dis-posal.

Disposal of the packaging
The packaging consists of cardboard and correspondingly marked plastics that can be recycled.

  • Make these materials available for recycling.

Technical data

Material number/482274, 482282

  • Nominal voltage 230 V~, 50 Hz
  • Rated power input 2900 W
  • Protection class I
  • Protection class IPX0
  • Permitted ambient temperature +17…+35 °C
  • Product size 440 × 715 × 335 mm
  • Net weight 28 kg
  • Coolant R290, 212 g

Remote control

  • Battery 2× LR03, AAA, 3V
Information requirements

euromate-482274-Local-Air-Conditioner-Unit-fig- \(13\)

Note:
The leaking of coolant contributes towards climatic change. Cooling with a low greenhouse potential make, in the event of leakage, a smaller contribution towards the warming of the earth than those with a higher greenhouse potential. This device contains a coolant with a greenhouse poten-tial of 3. Thus, the leaking of 1 kg of this cool-ant would have 3 times greater effect on the warming of the earth than 1 kg CO2, related to one hundred years. Do not carry out work on the cooling circuits or dismantle the device. Always consult a specialist.

Claims for defects

  • Dear customer, Our products are manufactured in modern production plants, and are subject to an internationally recognised quality process.
  • Nevertheless, if you have cause for dissatisfaction, please bring the item together with the proof of purchase to the store from which you bought it.
  • For our products, legal claims for defects are valid from the date of purchase.

Euromate GmbH

  • Emil-Lux-Straße 1 42929 Wermelskirchen GERMANY
  • Hotline +49 (0) 2196 / 76-3333 www.euromate.de
  • Art.-Nr. 482274, 482282

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals