MOBIAKCARE 0806296 Anti-Decubitus Striped Cushion for Wheelchairs with Air Pump User Manual
- June 12, 2024
- MOBIAKCARE
Table of Contents
USER MANUAL:
ANTI-DECUBITUS STRIPED CUSHION FOR WHEELCHAIRS WITH AIR
PUMP 0806296
ANTI-DECUBITUS STRIPED CUSHION FOR WHEELCHAIRS WITH
ΒΑΤΤΕRΥ AIR PUMP 0806246
Read the instruction manual before use and keep it for future reference.
Important safety instructions
PRODUCT DESCRIPTION
Air cushions can reduce & cure bed ulcers in chronic diseased patients or for
people who sit on wheelchair or armchairs for long periods. They can be used
for home care use. They distribute evenly pressure on the body to prevent
edema.
The air pump alternates the air pressure on the cushion with a feeling of
light massage & activates immobilized cells due to the prolonged sitting.
This product is indicated for patients who spend more than 15 hours a day in a
chair, armchair or wheelchair.
OPERATION USE
For air cushion:
- Check for sharp objects on the patient’s seat (wheelchair, armchair, chair, etc.), and then place the air cushion on. Make sure the air inlet pipes are on the same side of the pump and are not folded.
- Attach the air cushion to the pump by using the hoses in the package and install correctly.
For the pump
- Use the hooks behind the pump to hang the pump onto the wheelchair armrest. Connect the pump to the nearest wall outlet (not an extension cord) and adjust the air flow according the weight of the patient with the rotary selector on the top of the device.
SPARE PARTS
REF. NUMBER | DESCRIPTION |
---|---|
806297 | STRIPED AIR CUSHION |
806272 | PUMP FOR ANTI-DECUBITUS BUBBLE MATTRESS MINOA |
806299 | PUMP WITH BATTERY |
DESCRIPTION OF INDICATORS AND FUNCTIONS FOR THE AIR PUMP
- Power switch
- Rotary pressure switch.
- Air outlets
PUMP | Voltage (V) – Frequency (Hz) | AC220-240V/ 50HZ |
---|---|---|
Air Output | 5-6 lit/min | |
Pressure Range | 50mmHg — 110mmHg | |
Cycle Time | 12min | |
Power Consumption | < 7 W ± 10% | |
Noise | 30 dB ± 10% | |
Dimensions (LxWxH) | 22,5 x 10,5 x 8,1 cm | |
Pump Weight | 1 Kg | |
AIR CUSHION | Max. patient weight (Kg) | 120 Kg |
--- | --- | --- |
Color | Blue | |
Material | Nylon TPU & Stretch PU for the cover | |
Cushion height (cm) | 10 cm | |
Dimension (LxWxH) | 43 x 43 x 10 cm | |
Air tubing length (cm) | 75 cm | |
Weight (Kg) | 2 Kg |
DESCRIPTION OF INDICATORS AND FUNCTIONS FOR THE BATTERY PUMP
- Start button (press for two seconds)
- Operation mode selection key
- Circle time selection key
- Pressure adjustment knob
- “Mute” key
- Battery charging indicator
- Air outlets
- Charger input
- Power switch
AIR PUMP| Voltage (V) — Frequency (Hz) –| 100-220 VAC/ 50Hz – Li-Battery 11.1V
2200 mAh
---|---|---
Pump autonomy (h)| 12 hours (Pressure level 1)
Air outlet (lit/min)| > 4 liters / min
Pressure range (mmHg)| 30 – 70 mmHg
Time cycle (min)| 10 / 15 / 20 min
Noise (dB)| 30 dB ± 10%
Dimensions (LxWxH)| 34,5 x 11 x 5,5 cm
Pump weight (Kg)| 1,111 Kg
The air cushion pump has two functions: Alternative or Static.
ALTERNATIVE:
In ALTERNATING mode, the tubes inflate and deflate, and change the patient’s
contact area.
STATIC:
In STATIC mode, all tubes are inflated simultaneously to give the patient
uniform support throughout the contact area.
-
Switching time selection.
When ALTERNATING is selected, the user can choose whether they want the tubes to rotate faster or slower during the time of an alternating cycle. There are 3 selection cycles such as 10 minutes, 15 minutes or 20 minutes. -
Pressure level adjustment
The pressure level can be adjusted from soft (1) to hard (5). The user can select the most comfortable pressure by using the pressure adjustment key.
(The duration of each step depends on battery capacity) -
MUTE
If the alarm is on, the pump will make BEEP sounds to alert the user for the alarm.
However, the user can mute the BEEP by pressing the mute button.
The Mute function will be deactivated by pressing the mute button again (5). -
Charging the battery
Step 1- > Connect the power plug to the power input.
Step 2- > Connect the power adapter to an A / C wall outlet.
Step 3- > LED 6 lights up and starts charging.
Step 4- > During the charging of the battery a light indicator is on.
Step 5- > the light indicator turns off when the battery is fully charged.
Step 6- > when the battery is fully charged, make sure you unplug the power adapter from the pump before unplugging it from the A / C socket.
(Disconnecting in reverse order can cause serious damage to the pump).
NOTICE
- Make sure you have fully charged the battery before the first use.
- Do not use the battery when the capacity is too low. (LED LOW BATTERY flashes red).
- The pillow will not work if the battery is not properly inserted.
- It is normal if the battery heats up after charging or use.
- It is highly recommended to use only the batteries provided by the pump manufacturer. Using other batteries can cause serious unforeseen risks.
STORAGE
- Switch off the device, unplug it from the power supply and disconnect the air-cushion from the pump.
- Place the air-cushion on a flat surface and roll or fold it from top to bottom.
- Allow air slowly escape the cushion to reduce storage space
- Close the protective cap cover on the quick connector.
- Place air-cushion & the pump in the carrying bag (if available) and store it in a moisturefree place.
IMPORTANT (!)
In case of damage or malfunction of the pump, please contact your authorized
and trained agent.
MAINTENANCE
To clean the cushion use a soft cloth or sponge & water with mild soap.
ATTENTION:
- Do not use acidic & caustic dilutions.
- Do not smoke & do not use any flame near the cushion.
- Do not have the cushion in contact with direct heat sources.
- If you need to save the cushion, empty of air, by folding it
- Keep or store the pump in a clean, dry and well ventilated environment.
- Before you clean the pump, disconnect from the power supply.
- Clean the pump with a dry cloth.
ATTENTION:
Do not bring the pump in contact with liquids.
IMPORTANT (!)
CAUTIONS
- Do not disconnect the hoses while the pump is on.
- Do not use sharp objects near the cushion.
- Do not exceed the maximum load (kg) recommended by the manufacturer.
- Do not use, while bathing the patient.
- Protect the product by oils, lotions and creams, by covering it with the cotton wool fabric, or a bath towel.
- Do not use alcohol-based cleaning products to clean the cushion. This could damage the material of the layer.
- Clean the upholstery after each daily use. We recommend to clean the upholstery with a mild detergent to protect it from oil stains and dust. A common practice is to use a spray bottle with a mixture of antibacterial soap and water. Spray the surface and then wipe with a clean towel. The best solution is to be cleaned with warm water mixed with a mild soap and then thoroughly dried.
- Protect the layer from scratches, cuts and punctures.
- Do not leave the product on, if it is not in a use.
CAUTION (!)
Do not use the product for a purpose not indicated in this manual
Only qualified person or trained for the treatment and prevention of bedsore,
can operate with the device
MOBIAK S.A declines all responsibilities for any consequences resulting from
an incorrect use of this product and from unauthorized alteration to the
product.
MOBIAK S.A reserves the right to change the information contained in this
document without previous notice.
EC Declaration of Conformity
We are solely responsible for declaring that the Medical Devices mentioned in
this statement are of Low-Risk Class (Class I) and comply with the
requirements of the European Regulation 745/2017 and where appropriate, the
standards and legislation referred to.
**ENVIRONMENTAL PROTECTION**
If one day you find that your product needs to be replaced or it is no longer
working for you, consider protecting the environment:
- Do not dispose your product along with the rest of the public waste (this is also the meaning of the shown recycling sign).
- Contact your Public Authorities and they will instruct you of the Recycling centers to which your product must be disposed.
- Correct disposal of your product helps the protection of the environment as well as the recycling of the product’s components.
- The electrical products due to their construction materials, if not correctly disposed, may lead to environmental and furthermore health hazards
WARRANTY
The product has warranty for two (2) years in pump, six (6) months on the
cushion and three (3) months for the battery from purchase date.
The warranty covers factory defects and not damages resulting from improper
use / maintenance of the product.
The warranty apply factory defects & DOES NOT apply damages resulting from
improper use , poor maintenance, modification, abuse or non-compliance with
the product’s operating instructions.
Damage or defects caused by natural disasters, unauthorized maintenance or
repair, power supply problems (where applicable) and transportation companies
are not covered by the warranty.
Warranty Form
Buyers Data
Name: …………………………………………
Date of purchase: ……………………………
S/N…………………………………..
LOT:………………………………………..
Phone: …………………………………..
Resellers Data
Name : …………………………………………
Address:…………………………………………
Phone: ……………………………….
Reseller Stamp
INCIDENT REPORTING:
Any serious incident that occurs in relation to use of the device must be
reported to the manufacturer and a competent authority of the Member State in
which the user and / or patient resides.
| Medical Device
---|---
| Manufacturer
| Product Number
| Serial Number
| Batch Number
| Unique Device identification
| Keep Dry
| Handle With Care
| In the door Use Only
| CE Mark
| Production Date
****| Read the instruction for use
| Do not use if Package is Damage
| Right Way Up
| Keep away from sunlight
| Stacking Height
| IFragile
| Waste Electrical and Electronic Equipment Directive
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>