esera 11160 1 Wire Multisensor Pro Temperature User Guide
- June 13, 2024
- esera
Table of Contents
Art. Nr. 11160
Quick Guide
1-Wire Multisensor Pro Unterputz / flush-mounted
11160 1 Wire Multisensor Pro Temperature
- Professional temperature and humidity sensor for private, schools, public buildings and companies
- Highly accurate temperature and humidity sensor Temperature +/- 0,3°C Humidity +/-3% rel. humidity
- Universal flush mounting for almost all switch series
- Easy mounting in 55mm flush-mounted boxes
- Central plates available in pure white matt and glossy
- Simple power supply (5VDC)
Introduction
Thank you for choosing a device from ESERA.
With the ESERA 1-Wire Multisensor Pro you have purchased a professional and
highly accurate Multisensor.
It allows easy climate monitoring of all rooms and buildings.
Note
The module may only be operated at the voltages and ambient conditions
provided for it. The operating position of the device is arbitrary.
The modules may only be put into operation by a qualified electrician.
For further information on the operating conditions, see the following
instructions under “Operating conditions” in the User Guide.
Note
Before you start assembling the device and putting the product into operation,
please read this Quick Guide carefully until the end, especially the section
on safety instructions.
Please download the complete User Guide in PDF format from our website.
In the detailed User Guide you will find further information about the device,
installation, function and operation.
The User Guide, connection diagram and application examples can be found at
https://download.esera.de/pdflist
If you have problems with downloading the documents, please contact our
support by mail at support@esera.de
We are very careful to act in an environmentally friendly and resource-saving
way for you. That is why we use paper and cardboard instead of plastics
wherever possible.
We would also like to make a contribution to the environment with this Quick
Guide.
Assembly
The mounting location must be protected from moisture, e.g. dripping water and drafts. The device may only be used in dry indoor rooms and is intended for installation inside a living space as a stationary device.
Disposal note
Do not dispose of the unit in household waste! Electronic devices must be disposed of at the local collection points for electronic devices in accordance with the Directive on Waste Electrical and Electronic Equipment!
Safety instructions
When handling products that come into contact with electrical voltage, the applicable VDE regulations must be observed, in particular VDE 0100, VDE 0550/0551, VDE 0700, VDE 0711 and VDE 0860.
- All final or wiring work must be carried out with the power turned off.
- Before opening the device, always unplug or make sure that the unit is disconnected from the mains.
- Components, modules or devices may only be put into service if they are mounted in a contact proof housing. During installation they must not have power applied.
- Tools may only be used on devices, components or assemblies when it is certain that the devices are disconnected from the power supply and electrical charges stored in the components inside the device have been discharged.
- Live cables or wires to which the device or an assembly is connected, must always be tested for insulation faults or breaks.
- If an error is detected in the supply line, the device must be immediately taken out of operation until the faulty cable has been replaced.
- When using components or modules it is absolutely necessary to comply with the requirements set out in the accompanying description specifications for electrical quantities.
- If the available description is not clear to the non-commercial end-user what the applicable electrical characteristics for a part or assembly are, how to connect an external circuit, which external components or additional devices can be connected or which values these external components may have, a qualified electrician must be consulted.
- It must be examined generally before the commissioning of a device, whether this device or module is basically suitable for the application in which it is to be used.
- In case of doubt, consultation with experts or the manufacturer of the components used is absolutely necessary.
- For operational and connection errors outside of our control, we assume no liability of any kind for any resulting damage.
- Kits should be returned without their housing when not functional with an exact error description and the accompanying instructions. Without an error description it is not possible to repair. For time-consuming assembly or disassembly of cases charges will be invoiced.
- During installation and handling of components which later have mains potential on their parts, the relevant VDE regulations must be observed.
- Devices that are to be operated at a voltage greater than 35 VDC / 12mA, may only be connected by a qualified electrician and put into operation.
- Commissioning may only be realized if the circuit is built into a contact proof housing.
- If measurements with an open housing are unavoidable, for safety reasons an isolating transformer must be installed upstream or a suitable power supply can be used.
- After installing the required tests according to DGUV / regulation 3 (German statutory accident insurance, https://en.wikipedia.org/wiki/German_Statutory_Accident_Insurance) must be carried out.
ESERA GmbH guarantees that the goods sold at the time of transfer of risk to
be free from material and workmanship defects and have the contractually
assured characteristics. The statutory warranty period of two years begins
from date of invoice. The warranty does not extend to the normal operational
wear and normal wear and tear. Customer claims for damages, for example, for
non-performance, fault in contracting, breach of secondary contractual
obligations, consequential damages, damages resulting from unauthorized usage
and other legal grounds are excluded. Excepting to this, ESERA GmbH accepts
liability for the absence of a guaranteed quality resulting from intent or
gross negligence. Claims made under the Product Liability Act are not
affected.
If defects occur for which ESERA GmbH is responsible, and in the case of
replacement goods, the replacement is faulty, the buyer has the right to have
the original purchase price refunded or a reduction of the purchase price.
ESERA GmbH accepts liability neither for the constant and uninterrupted
availability of the ESERA GmbH or for technical or electronic errors in the
online offer.
We develop our products further and we reserve the right to make changes and
improvements to any of the products described in this documentation without
prior notice. If you need documentation or information about older product
versions, contact us by email at info@esera.de.
Trademarks
All mentioned designations, logos, names and trademarks (including those which
are not explicitly marked) are trademarks, registered trademarks or other
copyright or trademarks or titles or legally protected designations of their
respective owners and are hereby expressly recognized as such by us. The
mention of these designations, logos, names and trademarks is made for
identification purposes only and does not represent a claim of any kind on the
part of ESERA GmbH on these designations, logos, names and trademarks.
Moreover, from their appearance on ESERA GmbH webpages it cannot be concluded
that designations, logos, names and trademarks are free of commercial property
rights. ESERA and Auto-E-Connect are registered trademarks of ESERA GmbH.
Auto-E-Connect is registered by ESERA GmbH as a German and European Patent.
ESERA GmbH is a supporter of the free internet, free knowledge and the free
encyclopedia Wikipedia.
We are a member of Wikimedia Deutschland e.V., the provider of the German site
Wikipedia (https://de.wikipedia.org). ESERA membership number: 1477145
Wikimedia Germany’s association purpose is the promotion of free knowledge.
Wikipedia® is a registered trademark of the Wikimedia Foundation Inc.
Contact
ESERA GmbH, Adelindastrasse 20, D-87600 Kaufbeuren, Deutschland / Germany
Tel.: +49 8341 999 80-0, Fax: +49 8341 999 80-10
WEEE-Nummer:DE30249510
www.esera.de
info@esera.de
ESERA GmbH 2022. All rights reserved. Reproduction as well as electronic
duplication of this user
guide, complete or in part, requires the written consent of ESERA GmbH.
Subject to technical changes.
ESERA GmbH 2022.
www.esera.de
11160_QuickGuide
Seite 4 von 4
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>